High-quality pressure sensor with mounted diaphragm seal
Description
Diaphragm seal systems are used to protect the pressure measuring instrument from aggressive, adhesive, crystallising, corrosive, highly viscous, environmentally hazardous or toxic media. The diaphragm made of stainless steel provides for the separation from the medium. The pressure is transmitted to the measuring instrument via the system fill fluid which is inside the diaphragm seal system.
Due to its design - with open flange connection and internal diaphragm - the DSS26T is suitable for all currently used standard flanges and is mounted to small process connections for pressure measurement.
Special features
- Open flange with internal, all welded diaphragm
- No sealings and clamping elements
- Robust, all welded design
- Compact design
Build a DSS26T for your task
The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.
- Pressure measuring instrumentHigh-quality pressure transmitter
- Unitbar
- Measuring range—
- Output signal4 ... 20 mA, 2-wire
- Power supplyDC 8...35 V
- Electrical connectionangular connector DIN 175301-803 A
- Assemblydirect assembly
- System fill fluidKN 2 Silicone oil for general applications
- Unit of temperatureCelsius
- Process temperature min.- 10 °C
- Process temperature max.+ 150°C
- Ambient temperature pressure meas. min+ 10 °C
- Ambient temperature pressure meas. max+ 40 °C
- Process connection standard—
- Process connection—
- Nominal pressure rating—
- Sealing face—
- Wetted partsStainless steel 1.4404/1.4435 (316L); UNS S31603
- Certificateswithout
Finish your configuration
Select every option to submit the request.
| Model | DSS26T |
| Product family | DSS |
| Subcategory | Diaphragm seal system with integrated pressure sensor |
| Pressure ranges | 0…6 bar · 0…10 bar · 0…16 bar · 0…25 bar · -1…5 bar · -1…9 bar · -1…10 bar |
| Accuracy class | 0.5 |
| Accuracy standard | IEC 61298-1 |
| Process connection | Flange EN 1092-1 DN25 PN10/40Flange ASME B16.5 ½" Class 150/300Flange ASME B16.5 1" Class 150/300Flange EN 1092-1Flange ASME B16.5Flange connection following EN 1092-1Flange connection following ASME B16.5 |
| Process temperature | −10…+150 °C |
| Output signal | 4-20mA · 4-20mA (2-wire) |
| Power supply | DC 8 ... 35 V |
| Electrical connection | Angular connector DIN 175301-803 A |
| Case material | Stainless steel 1.4571 (316Ti) |
| Wetted parts material | Stainless steel 1.4435 (316L), Diaphragm: Stainless steel 1.4435 (316L), Upper body of diaphragm seal: Stainless steel 1.4435 (316L) |
| Sealing material | Silicone oil KN 2 |
| Ambient temperature | +10…+40 °C |
| IP rating | IP65 |
| Certifications | 3.1 inspection certificate per EN 10204CERoHSREACHEN 10204 |
| Datasheet languages | EN, DE |
| Model DSS26T | |
|---|---|
| Design | High-quality pressure sensor, flange-type diaphragm seal, internal diaphragm |
| Current output | 4 ... 20 mA(2-wire) |
| Power supply | DC 8 ...35V |
| Accuracy at reference conditions | ≤ ±0.5 %of span |
| Permissible load in Ω | ≤ (power supply - 7.5 V) / 0.023 A |
| Current supply | Max.25mA |
| Dissipation loss | 828mW |
| Reference conditions (per IEC 61298-1) | Temperature: 15 ... 25 °C (59 ... 77 °F) Atmospheric pressure: 860 ... 1,060 mbar (12.5 ... 15.4 psi) Humidity: 45 ... 75 %r.h. Power supply:DC 24V Mounting position: Calibrated in vertical mounting position with pressure connection facing downwards |
| Pressure limitation | < 10 bar (150 psi): 3 times ≥ 10 bar (150 psi): 2 times |
| Permissible temperature range Medium Ambient Storage | -10 ...+150 °C (14 ... 302 °F) 10 ... 40 °C (50 ... 104 °F) 10 ... 60 °C (50 ... 140 °F) |
| Ingress protection | IP65 per IEC/EN 60529 |
| Material wetted non-wetted | Diaphragm: Stainless steel 1.4435 (316L) Upper body of diaphragm seal, stainless steel 1.4435 (316L) Case: Stainless steel 1.4571 (316Ti) Zero adjustment ring: PBT/PET GF30 Angular connector: PBT/PET GF30 |
| Level of cleanliness of wetted parts | Oil and grease free per ASTM G93-03 level F and ISO 15001 (< 1,000 mg/m²) |
| System fill fluid | Silicone oil KN 2 for general applications |
| Permissible humidity (per IEC 68-2-78) | ≤ 67 %r.h. at 40 °C (104 °F) (in accordance with 4K4H per EN 60721-3-4) |
| Vacuum and +/- measuring range | ||
|---|---|---|
| -1 ...+5 (-30 inHg ... +70) | -1 ...+9 (-30 inHg ... +130) | -1 ...+10 (-30 inHg ... +145) |
| Electrical connection | Ingress protection | Wire cross-section | Cable∅ | Permissible temperature |
|---|---|---|---|---|
| with mating connector | IP65 | max. 1.5 mm² | 6 ...8mm | -30 ...+100 °C (-22 ...+212 °F) |
| U+ | 1 | |
|---|---|---|
| U- | 2 | |
| Shield (option) | 4 |
View all (5)
| DN | Class | Dimensions in mm(in) | x | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| H | Mb | D | b | f | k | d 2 | d 4 | |||
| ½" | 150 | 158 (6.221) | 32 (1.26) | 90 (3.543) | 22 (0.866) | 2 (0.079) | 60.3 (2.374) | 16 (0.63) | 34.9 (1.374) | 4 |
| 300 | 40 (1.574) | 95 (3.740) | 66.7 (2.626) | |||||||
| 1" | 150 | 52 (2.047) | 110 (4.330) | 79.4 (3.126) | 50.8 (2.0) | |||||
| 300 | 125 (4.921) | 88.9 (3.5) | 19 (0.748) |
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →16 standard articles of family DSS
If you know the code — pick directly. If not — use the configurator in mode “01”.