Pressure gauge in hygienic design with mounted diaphragm seal
Description
Diaphragm seal systems are used to protect the pressure measuring instrument from aggressive, adhesive, crystallising, corrosive, highly viscous, environmentally hazardous or toxic media. The diaphragm made of stainless steel provides for the separation from the medium. The pressure is transmitted to the measuring instrument via the system fill fluid which is inside the Diaphragm seal system.
The DSS22P complies with all requirements of the pharmaceutical industry. The particular suitability for pharmaceutical products rests on the fact that the measuring point can be cleaned while installed.
Special features
- Case and wetted parts in hygienic design
- Suitable for SIP and CIP
- Clamp connection easy to open for cleaning and seal replacement
- Easy zero point setting
Build a DSS22P for your task
The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.
- Pressure measuring instrumentManometer according to EHEDG nominal size 100 mm
- Unit of outer Scalebar
- Scale range—
- Assemblydirect assembly
- System fill fluidKN 92 Medicinal white mineral oil; for pharmaceutical and food applications; FDA, USP, EP
- Unit of temperatureCelsius
- Process temperature min.+ 10 °C
- Process temperature max.+ 80 °C; for sterilisation (SIP) max. + 130 °C
- Ambient temperature pressure meas. min+ 10 °C
- Ambient temperature pressure meas. max+ 40 °C
- pipe standard—
- Process connection—
- Wetted partsStainless steel 1.4435 (316L) electropolished; UNS S31603
- Surface roughness wetted parts, welding seam excludedRa ≤ 0,38 µm (Ra 0.15 µin.) according to ASME BPE SF4
- Certificateswithout
- Autoclavable versionno
Finish your configuration
Select every option to submit the request.
| Model | DSS22P |
| Product family | DSS22 |
| Subcategory | Pressure gauge with diaphragm seal |
| Pressure ranges | 0…2.5 bar · 0…4 bar · 0…6 bar · 0…10 bar · 0…16 bar · 0…25 bar · -1…5 bar · -1…9 bar · -1…10 bar · 0…1 bar · 0…1.6 bar |
| Accuracy class | 1.0 |
| Accuracy standard | EN 837-1 |
| Process connection | Clamp connection per DIN 32676Clamp connection per BS4825 part 3 |
| Process temperature | +10…+130 °C |
| Case material | Stainless steel 1.4301 [304] |
| Wetted parts material | Stainless steel 1.4435 [316L], Diaphragm: Stainless steel 1.4435 [316L], Diaphragm seal: stainless steel 1.4435 [316L] |
| Ambient temperature | +10…+40 °C |
| IP rating | IP65 |
| Certifications | EHEDGEN 10204 3.1 |
| Dial size | 100 mm |
| Datasheet languages | EN |
| Design | Pressure gauge with Bourdon tube in hygienic design, welded to diaphragm seal, electropolished | |
|---|---|---|
| Nominal size (NS) | 100 | |
| Accuracy class | 1.0 | |
| Scale range | 0 ... 6 to 0 ... 25 bar [0 ... 87 to 0 ... 360 psi] or all other equivalent vacuum or combined pressure and vacuum ranges | |
| Pressure limitation | Steady: Fluctuating: Short time: | Full scale value 0.9 x full scale value 1.3 x full scale value |
| Permissible temperature range | ||
| Medium Ambient Storage | 10 ... 80 °C [50 ... 176 °F] for CIP and SIP max. 130 °C [266 °F] 10 ... 40 °C [50 ... 104 °F] 10 ... 60 °C [50 ... 140 °F] | |
| Ingress protection | IP65 per IEC/EN 60529 | |
| Material wetted | Diaphragm: Stainless steel 1.4435 [316L] Diaphragm seal: stainless steel 1.4435 [316L] Case: Stainless steel 1.4301 [304] Dial, pointer: Aluminium | |
| Surface roughness wetted non-wetted | Ra ≤ 0.38 µm [15 µin] per ASME BPE SF4 (except for weld seam) Case:Ra ≤ 0.38 µm [15 µin] (except for weld seam) | |
| Level of cleanliness of wetted parts | Oil and grease free per ASTM G93-03 level F and ISO 15001 (< 1,000 mg/m²) | |
| System fill fluid | Medicinal white mineral oil KN 92 (FDA 21 CFR 172.878, 21 CFR 178.3620(a); USP, EP, JP) |
| Gauge pressure | 0 ... 2.5 [0 ... 40] | 0 ... 4 [0 ... 60] | |
|---|---|---|---|
| 0 ... 6 [0 ... 100] | 0 ... 10 [0 ... 160] | 0 ... 16 [0 ... 250] | 0 ... 25 [0 ... 300] |
| DN | For pipe | PN 1) | Dimensions in mm[in] | |||
|---|---|---|---|---|---|---|
| Outer Ø x wall thickness | NG | H | D | Mb | ||
| 1 ½" | 38.1 x 1.65 [1.5 x 0.065] | 40 | 100 [3.937] | 115 [4.528] | 50.5 [1.988] | 32 [1.26] |
| 2" | 50.8 x 1.65 [2 x 0.065] | 40 | 100 [3.937] | 118 [4.646] | 64 [2.52] | 40 [1.575] |
| DN | For pipe | PN 1) | Dimensions in mm[in] | |||
|---|---|---|---|---|---|---|
| Outer Ø x wall thickness | NG | H | D | Mb | ||
| 42.4 (DN 32) | 42.4 x 2 [1.669 x 0.079] | 40 | 100 [3.937] | 118 [4.646] | 64 [2.52] | 32 [1.26] |
| 48.3 (DN 40) | 48.3 x 2 [1.906 x 0.079] | 40 | 100 [3.937] | 118 [4.646] | 64 [2.52] | 40 [1.575] |
View all (6)
| DN | For pipe | PN 1) | Dimensions in mm[in] | |||
|---|---|---|---|---|---|---|
| Outer Ø x wall thickness | NG | H | D | Mb | ||
| 1 ½" | 38.1 x 1.6 [1.5 x 0.063] | 40 | 100 [3.937] | 115 [4.528] | 50.5 [1.988] | 32 [1.26] |
| 2" | 50.8 x 1.6 [2 x 0.063] | 40 | 100 [3.937] | 118 [4.646] | 64 [2.52] | 40 [1.575] |
| Logo | Description | Country |
|---|---|---|
| EHEDG | European Community | |
| FEBRUARY 2021 TYPE EL CLASS I | Hygienic Equipment Design |
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →28 standard articles of family DSS22
If you know the code — pick directly. If not — use the configurator in mode “01”.