WIKA · Pressure measurement · Family DSS

Pressure gauge per EN 837-1 with mounted diaphragm seal

With process connection per Svensk Standard SS 1145, for food
Range
-1…25 bar
Accuracy
1.0
Protection
IP65
EN 837-1ASME BPE SF3ASTM G93-03EN 10204 3.1
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The DSS19F complies with the requirements of the food industry. The threaded connection enables a hygienic process connection.

The requirements of COP (cleaning out of place) are fulfilled.

The diaphragm seal systems can withstand the cleaning vapour temperatures occurring in the SIP processes and thus ensure a sterile connection between the medium to be measured and the diaphragm seal.

Special features

  • Quick cleaning, without residue
  • Process connection per Svensk Standard SS 1145
  • Suitable for cleaning out of place (COP)
  • Sterilisation-in-Place (SIP) up to max. 130 °C [266 °F]
Configurator · Step by step

Build a DSS19F for your task

The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.

Step 1 of 2
Configuration structure· click a highlighted segment to jump to that parameter

The scale range of a pressure gauge defines the scale start value and full scale value of the scale printed on the dial of the pressure gauge. The correct scale range depends on the process pressure of the respective application and the process conditions. There are predefined standard scale ranges for pressure gauges in accordance with European and American standards. For special display ranges, please contact WIKA support. Ideally, the process pressure of the application should be approx. 2/3 of the full scale value of the pressure gauge. Example: For a process pressure of 40 bar, for example, a pressure gauge with a scale range of 0 to 60 bar would therefore be recommended.

Your configuration
  • Pressure measuring instrumentManometer according to EN 837-1 nominal size 100 mm
  • Case fillingwithout
  • Unit of outer Scalebar
  • Scale range—
  • Assemblydirect assembly
  • System fill fluidKN 92 Medicinal white mineral oil; for pharmaceutical and food applications; FDA, USP, EP
  • Unit of temperatureCelsius
  • Process temperature min.+ 10 °C
  • Process temperature max.+ 80 °C; for sterilisation (SIP) max. + 130 °C
  • Ambient temperature pressure meas. min+ 10 °C
  • Ambient temperature pressure meas. max+ 40 °C
  • Process connection specificationGrooved union nut
  • pipe standardPipe dimensions per DIN 1127 row 2 or ISO 2037/1992
  • Process connection—
  • Wetted partsStainless steel 1.4435 (316L); UNS S31603
  • Surface roughness wetted parts, welding seam excludedRa ≤ 0,76 µm (Ra 0.30 µin.) according to ASME BPE SF3
  • Certificateswithout