WIKA · Pressure measurement · Family DPT
Electronic differential pressure transmitter
In primary and secondary circuits
Output
4-20 mA with HART · 4-20mA
Accuracy
See individual transmitter data sheets (IPT-2x
Protection
IP65
NAMUR NE21NAMUR NE43NAMUR NE53NAMUR NE1073.1 inspection certificate2.2 test reportDAkkS calibration certificate
Price
On request
Depends on configuration
Description
In the process industry, differential pressure measurement using primary and secondary circuits has several advantages over conventional differential pressure methods. The measuring locations, which are usually several metres apart, are connected via a flexible and easily routed cable. This eliminates the need for capillaries, which are complex to install and susceptible to temperature changes.
Special features
- Simple, uncomplicated installation
- Mounting possible without diaphragm seal
- Elimination of capillaries, that can easily kink
- For applications to SIL 2 (SIL 3)
- Can be combined with two different designs of transmitters from model IPT-2x and/or model CPT-2x
Identification
| Model | DPT-EL |
| Product family | DPT |
| Subcategory | Differential pressure transmitter |
Accuracy
| Accuracy class | See individual transmitter data sheets (IPT-2x, CPT-2x) |
| Safety integrity level (SIL) | SIL 2 (option), up to SIL 3 in multi-channel redundant operation |
Process conditions
| Process connection | G 1/2 flushG 1 flushG 1 1/2 flushG 1 hygienic flush |
Electrical characteristics
| Output signal | 4-20 mA with HART · 4-20mA · FOUNDATION™ Fieldbus · FOUNDATION Fieldbus · PROFIBUS PA · PROFIBUS ® PA |
| Power supply | DC 12...35 V (non-Ex), DC 12...30 V (Ex ia) |
| Electrical connection | 4-core spring-clip terminals |
Materials
| Case material | PBT, polyester, Stainless steel 316L, Die-casting AlSi10Mg, powder-coated on PE basis, Die-casting AlSi10Mg, powder-coated |
Operating environment
| Ambient temperature | −40…+85 °C |
| IP rating | IP65 |
Certifications and approvals
| Certifications | NAMUR NE21NAMUR NE43NAMUR NE53NAMUR NE1073.1 inspection certificate2.2 test reportDAkkS calibration certificateTest certificate for measurement accuracy |
Additional details
| Datasheet languages | EN, DE |
Tables from datasheet
| Model | Description |
|---|---|
| Models IPT-20 and IPT-21 | Process transmitter with metal measuring cell with open pressure port or with flush process connection |
| Models CPT-20 and CPT-21 | Process transmitter with ceramic measuring cell with open pressure port or with flush process connection |
Connecting cable between primary and secondary instrument
| Mechanical data | |
|---|---|
| Construction | Wires, strain relief, braided screen, metal foil, sheath |
| Standard length | 5 m[16.4 ft] |
| Max. length | 25 m[82.02 ft] |
| Min. bending radius (at 25 °C [77 °F]) | 25 mm[0.985 in] |
| Diameter | ■ Approx. 8 mm[0.315 in] ■ Approx. 6 mm[0.236 in] |
| Material | PE, PUR |
| Colour | Black |
| Electrical data | |
| Wire cross-section | 0.34 mm² (AWG 22) |
| Wire resistance | < 0.05 Ω/m [0.015 Ω/ft] |
Output signal
| Signal types | ■ 4 ...20mA ■ 4 ... 20 mAwith a superimposed HART ® communication signal (option: SIL qualification) ■ HART ® specification: 7.3 ■ FOUNDATION™ Fieldbus ■ PROFIBUS ® PA |
|---|---|
| Load in Ω | (U B - U Bmin ) / 0.022 A |
| Damping | 0 ... 999 s, adjustable After the set damping time the instrument outputs 63 %of the applied pressure as output signal. |
| Step response time | < 80 ms (= dead time < 25 ms + rise time 10 ... 90 %<55ms) |
| Signal type | Backlighting | |
|---|---|---|
| Inactive | Active | |
| 4 ... 20 mA | DC 12 ...35V | DC 16 ...35V |
| 4 ... 20 mA with a superimposed HART ® communication signal | DC 12 ...35V | DC 16 ...35V |
| FOUNDATION™ Fieldbus | DC 12 ...32V | DC 16 ...32V |
| PROFIBUS ® PA | DC 12 ...32V | DC 16 ...32V |
View all (8)
| Signal type | Backlighting | |
|---|---|---|
| Inactive | Active | |
| 4 ... 20 mA | DC 12 ...30V | DC 16 ...30V |
| 4 ... 20 mA with a superimposed HART ® communication signal | DC 12 ...30V | DC 16 ...30V |
| FOUNDATION™ Fieldbus | DC 12 ...24V (DC 12 ...17.5V Fisco) | DC 16 ...24V (DC 16 ...17.5V Fisco) |
| PROFIBUS ® PA | DC 12 ...24V (DC 12 ...17.5V Fisco) | DC 16 ...24V (DC 16 ...17.5V Fisco) |
Material
| Case, primary instrument | |
|---|---|
| Single chamber case, plastic | PBT, polyester |
| Single chamber case, aluminium | Die-casting AlSi10Mg, powder-coated on PE basis |
| Single chamber case, cast stainless steel | Stainless steel 316L |
| Single chamber case, electropolished stainless steel, deep-drawn | Stainless steel 316L |
| Double chamber case, plastic | PBT, polyester |
| Double chamber case, aluminium | Die-casting AlSi10Mg, powder-coated on PE basis |
| Double chamber case, cast stainless steel | Stainless steel 316L |
| Case, secondary instrument | |
| Single chamber case, plastic | PBT, polyester |
| Single chamber case, aluminium | Die-casting AlSi10Mg, powder-coated on PE basis |
| Single chamber case, cast stainless steel | Stainless steel 316L |
| Single chamber case, electropolished stainless steel, deep-drawn | Stainless steel 316L |
| Logo | Description |
|---|---|
| SIL IEC 61508 / IEC 6151 | SIL 2 (option) 1) Functional safety ■ 1-channel operation up to SIL 2 ■ Multi-channel operation (homogeneous, redundant) up to SIL 3 |
| - | NAMUR recommendations NE21 - Electrical compatibility of equipment NE43 - Signal level for failure information NE53 - Compatibility of field instruments NE107 - Self-monitoring and diagnostics |
| Description | Order number | |
|---|---|---|
| Display module, model DIH52-F 5-digit display, 20-segment bar graph, without separate power supply, with additional HART ® func- tionality. Automatic adjustment of measuring range and span. Secondary-master functionality: Setting the measuring range and unit of the connected transmitter possible using HART ® standard commands. Optional: Explosion protection per ATEX | On request | |
| HART ® modem for USB interface, specifically designed for use with notebooks (model 010031) | 11025166 | |
| HART ® modem for RS-232 interface (model 010001) | 7957522 | |
| HART ® modem for Bluetooth interface Ex ia IIC (model 010041) | 11364254 | |
| PowerXpress HART ® modem, with optional power supply (model 010031P) | 14133234 | |
| Welding socket for process connection G½flush | 1192299 | |
| Welding socket for process connection G1flush | 1192264 | |
| Welding socket for process connection G1½flush | 2158982 | |
| Welding socket for process connection G1hygienic flush | 2166011 | |
| Instrument mounting bracket for wall or pipe mounting, stainless steel | 14309985 | |
| Overvoltage limit for transmitters, 4 ... 20 mA, ½NPT, series connection, Ex i and Ex d | 14013656 | |
| Overvoltage limit for transmitters, 4 ...20 mA, M20 x 1.5, series connection, Ex i and Ex d | 14002489 | |
| Overvoltage limit for transmitters, FF / PROFIBUS, ½NPT, series connection, Ex i and Ex d | 14013658 | |
| Model DI-PT-R display and operating module, case cover aluminium with window | 12298884 | |
| Model DI-PT-R display and operating module, case cover electropolished cast stainless steel with window | 13315269 | |
| Model DI-PT-R display and operating module, case cover plastic with window | 13315277 | |
| Model DI-PT-R display and operating module, case cover cast stainless steel with window for single chamber case | 12298906 | |
| Model DI-PT-R display and operating module, case cover cast stainless steel with window for double chamber case | 14045598 | |
| Model DI-PT-E external display and operating module, aluminium case | 12354954 | |
| Model DI-PT-E external display and operating module, cast stainless steel case | 12355101 | |
| Model DI-PT-E external display and operating module, plastic case | 14134247 |
Industry
Oil & Gas
Chemical and petrochemical industries
Industry
Chemistry / Pharma
Process engineering · Pharmaceutical industry
Industry
Food industry
Food and beverage industry
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →All variants · Article table
1 standard articles of family DPT
If you know the code — pick directly. If not — use the configurator in mode “01”.
Stock:
SKUConfigurationPriceStockAction
Showing 1 of 1. Price on request — an engineer will quote your configuration.