DPGT43.100 1
DPGT43.100
On order
WIKA · Pressure measurement · Family DPGT43

Differential pressure gauge with output signal

For the process industry, all-metal media chamber
Range
0…2500 kPa
Output
4-20mA · 0-20mA
Accuracy
1.6
Protection
IP65
CERoHSEACCRNEx UkraineNEPSIII 2G Ex ia IIC T6/T5/T4 GbII 2D Ex ia IIIB T135°C DbEx ia IIC T6/T5/T4 GbEx ia IIIB T135°C DbGas II 2G Ex ia IIC T6/T5/T4 GbDust II 2D Ex ia IIIB T135℃ DbGas Ex ia IIC T6/T5/T4 GbDust Ex ia IIIB T135℃ DbPAC KazakhstanMChSPAC Uzbekistan
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

Wherever the process pressure has to be indicated locally and, at the same time, a signal transmission to the central control or remote centre is desired, the model DPGT43 intelliGAUGE ® (patent, property right: e.g. DE 202007019025) can be used.

These differential pressure gauges are made of highly corrosion-resistant stainless steel and feature an all-metal sealing of the media chamber.

Therefore no elastomer sealing elements are required, so that a better long-term leak tightness is ensured. A high overload safety is achieved by the all-metal construction and the close-fitting design of the pressure element.

The robust diaphragm measuring system produces a pointer rotation proportional to the pressure. An electronic angle encoder, proven in safety-critical automotive applications, determines the position of the pointer shaft - it is a non-contact sensor and therefore completely free from wear and friction.

Special features

  • No configuration necessary due to “plug-and-play”
  • Signal transmission per NAMUR
  • Differential pressure measuring ranges from 0 … 16 mbar or 0 ... 10 inH 2 O
  • Individual, non-linear characteristic curves (e. g. x 2 or √x for flow measurement)
  • QR code on dial links to instrument-specific information
Identification
ModelDPGT43.100
Product familyDPGT43
SubcategoryDifferential pressure gauge with output signal
Measuring range
Pressure ranges0…16 mbar · 0…10 inH2O · 0…0.25 bar · 0…6 psi · 0…40 kPa · 0…160 mbar · 0…2500 mbar · 0…1.6 bar · 0…40 bar · 0…1.6 kPa · 0…2500 kPa · 0…150 inH2O · 0…600 psi · 0…25 mbar · 0…40 mbar · 0…60 mbar · 0…100 mbar · 0…250 mbar · 0…300 mbar · 0…400 mbar · 0…600 mbar · 0…1000 mbar · 0…1100 mbar · 0…1200 mbar · 0…1600 mbar · 0…0.4 bar · 0…0.6 bar · 0…1 bar · 0…2.5 bar · 0…4 bar · 0…6 bar · 0…7 bar · 0…10 bar · 0…14 bar · 0…16 bar · 0…20 bar · 0…25 bar · 0…30 bar · 0…2.5 kPa · 0…4 kPa · 0…6 kPa · 0…10 kPa · 0…16 kPa · 0…25 kPa · 0…30 kPa · 0…100 kPa · 0…160 kPa · 0…250 kPa · 0…300 kPa · 0…400 kPa · 0…600 kPa · 0…700 kPa · 0…800 kPa · 0…1000 kPa · 0…1400 kPa · 0…1600 kPa · 0…15 inH2O · 0…20 inH2O · 0…25 inH2O · 0…30 inH2O · 0…40 inH2O · 0…60 inH2O · 0…100 inH2O · 0…200 inH2O · 0…250 inH2O · 0…8 psi · 0…10 psi · 0…15 psi · 0…30 psi · 0…60 psi · 0…100 psi · 0…150 psi · 0…160 psi · 0…200 psi · 0…250 psi · 0…300 psi · 0…400 psi
Accuracy
Accuracy class1.6
Accuracy standardEN 837-3
Process conditions
Process connection
G ¼, female threadG ½ B, male thread¼ NPT, female thread½ NPT, male threadG¼G½½NPTG1/4G1/2B1/4NPT1/2NPT
Process temperature−20…+150 °C
Electrical characteristics
Output signal4-20mA · 0-20mA · 0-10V
Power supply12...30 V DC
Electrical connectionCable socket PA 6, black; M20 x 1.5 cable gland; 6 screw terminals + PE
Materials
Case materialStainless steel 1.4301 (304 SS), Stainless steel 1.4571 (316 Ti)
Wetted parts materialStainless steel 1.4571 (316 Ti), NiCr alloy (Inconel)
Sealing materialAll-metal sealing, Stainless steel
Operating environment
Ambient temperature−40…+60 °C
IP ratingIP65
Weight2.7 kg
Certifications and approvals
Certifications
CERoHSEACCRN
Explosion protection
Ex UkraineNEPSIII 2G Ex ia IIC T6/T5/T4 GbII 2D Ex ia IIIB T135°C DbEx ia IIC T6/T5/T4 GbEx ia IIIB T135°C DbIECEx Hazardous areas Gas Ex ia IIC T6/T5/T4 GbGas II 2G Ex ia IIC T6/T5/T4 GbDust II 2D Ex ia IIIB T135℃ DbGas Ex ia IIC T6/T5/T4 GbDust Ex ia IIIB T135℃ DbEACPAC KazakhstanMChSPAC UzbekistanCRN
Additional details
Dial size100 mm
Datasheet languagesEN, DE
Tables from datasheet
Accuracy specifications
Zero point setting
Instruments with case fillingWithout
Instruments without case filling■ Without ■ Setting by means of adjustable pointer
Influence of static pressure 1)
Span ≤ 0.25 bar [100 inH 2 O]±0.3 %/1 bar [14.5 psi]
Span ≥ 0.4 bar [160 inH 2 O]±0.04 %/1 bar [14.5 psi]
Accuracy of output signal
Accuracy±1 %of measuring span
Linearity error≤ 1 %of measuring span (terminal method) 2)
Influence of auxiliary power< 0.1 %of FS/10V
Influence of load≤ 0.1 %of FS
Long-term stability< 0.3 %of FS/a
Resolution0.13 %of full scale (10 bit resolution at 360°)
Measuring rate100 per minute
Temperature errorOn deviation from the reference conditions at the measuring system: ≤ ±0.5 %per 10 °C [≤ ±0.5 %per 18 °F] of full scale value
Reference conditions
Ambient temperature+20 °C [+68 °F]
mbar
0 ... 16 1) 0 ... 250 ... 160 0 ... 2500 ... 1,000 0 ... 1,100
0 ... 3000 ... 1,200
0 ... 400 ... 1,600
0 ... 600 ... 400
0 ... 1000 ... 6000 ... 2,500
bar0 ... 4
0 ... 0.25 0 ... 0.40 ... 60 ... 20 0 ... 25
0 ... 0.60 ... 70 ... 30
0 ... 10 ... 100 ... 40
0 ... 1.60 ... 14-
0 ... 2.50 ... 16-
kPa
0 ... 1.6 1) 0 ... 2.50 ... 40 0 ... 600 ... 700 0 ... 800
0 ... 40 ... 1000 ... 1,000
0 ... 60 ... 1600 ... 1,400
0 ... 100 ... 2500 ... 1,600
0 ... 160 ... 3000 ... 2,500
0 ... 250 ... 400-
0 ... 300 ... 600-
View all (20)
psi
0 ... 60 ... 600 ... 250
0 ... 80 ... 1000 ... 300
0 ... 100 ... 1500 ... 400
0 ... 150 ... 1600 ... 600
0 ... 300 ... 200-
mbar
-16 ... 0 1)-600 ... 0-50 ...+50
-25 ... 0-1,000 ... 0-80 ...+80
-40 ... 0-1,100 ... 0-125 ...+125
-60 ... 0-1,200 ... 0-200 ...+200
-100 ... 0-8 ...+8-300 ...+300
-160 ... 0-10 ...+15-500 ...+500
-250 ... 0-20 ...+20-600 ...+400
-400 ... 0-30 ...+30-1,000 ...+600
bar
-1 ... 0-1 ...+3-1 ...+15
-1 ... +0.6-1 ...+5-1 ...+24
psi
-15 ... 0 inHg-30 inHg ...+300
-30 ... 0 inHg-5 ...+5
-30 inHg ...+15-15 ...+15
-30 inHg ...+30-30 ...+30
-30 inHg ...+60-50 ...+50
-30 inHg ...+100-100 ...+100
-30 inHg ...+160-150 ...+150
-30 inHg ...+200-
kPa
-60 ... 0 -100 ... 0-15 ...+15 -20 ...+40-100 ...+500 -100 ...+700
-2 ...+4-100 ...+60-100 ...+900
-4 ...+6-100 ...+100-100 ... +1,000
-6 ...+4-100 ...+150-100 ... +1,500
-6 ...+10-100 ...+200-100 ... +2,400
-10 ...+6-100 ...+300-
-10 ...+15-100 ...+400-
Further details on: scale ranges
Unit■ mbar ■ bar ■ psi ■ kPa ■ MPa ■ mmH 2 O ■ inH 2 O
→ Other units on request
Overload safety and max. operating pressure (static pressure)The possibility of selection depends on the scale range. → See separate table
Dial
Scale layout■ Single scale ■ Dual scale
Scale colourSingle scaleBlack
Dual scaleBlack/red
MaterialAluminium
Customer-specific version■ Without ■ With special scale, e.g. linear pressure or square root incrementation
Other scales, e.g. with red mark, circular arcs or circular sectors, on request → Alternatively, adhesive label set for red and green circular arcs; see data sheet AC 08.03
Pointer
Instrument pointerWith case fillingStandard pointer, aluminium, black
Without case fillingAdjustable pointer, aluminium, black
Mark pointer/drag pointer■ Without Mark pointer on bayonet ring, adjustable
Pointer stop pin■ Without At 6 o&#x27;clock
Span 1)Overload safety / max. operating pressure (static) Either side max.
16 ... 40 mbar [10 ... 16 inH 2 O]■ 2.5 bar [36 psi] / 2.5 bar [36 psi] ■ 2.5 bar [36 psi] / 6 bar [87 psi] 2)
60 ... 250 mbar [25 ... 100 inH 2 O]■ 2.5 bar [36 psi] / 6 bar [87 psi] ■ 6 bar [87 psi] / 10 bar [145 psi] 2)
400 mbar [6 psi]■ 4 bar [58 psi] / 25 bar [363 psi] ■ 40 bar [600 psi] / 40 bar [600 psi] 2)
0.6 bar [10 psi]■ 6 bar [87 psi] / 25 bar [363 psi] ■ 40 bar [600 psi] / 40 bar [600 psi] 2)
1 bar [15 psi]■ 10 bar [145 psi] / 25 bar [363 psi] ■ 40 bar [600 psi] / 40 bar [600 psi] 2)
1.6 bar [30 psi]■ 16 bar [232 psi] / 25 bar [363 psi] ■ 40 bar [600 psi] / 40 bar [600 psi] 2)
2.5 ... 40 bar [60 ... 600 psi]■ 25 bar [363 psi] / 25 bar [363 psi] ■ 40 bar [600 psi] / 40 bar [600 psi] 2)
Process connection
Standard■ EN 837-3 ■ ANSI/B1.20.1
→ For valve manifolds for an instrument hook-up, see &#x27;Accessories and spare parts&#x27;.
Size
EN 837-3■ 2 x G¼, female thread ■ 2 x G½B,male thread
ANSI/B1.20.1■ 2 x ¼NPT, female thread ■ 2 x ½NPT, male thread
Restrictor■ Without ■ ∅0.6 mm[0.024"], stainless steel ■ ∅0.3 mm[0.012"], stainless steel
Material (wetted)
Media chambers with process connectionStainless steel 1.4571 (316 Ti)
Venting of the media chambersStainless steel 1.4571 (316 Ti)
Diaphragm element 1)Span ≤ 0.25 bar [100 inH 2 O]Stainless steel 1.4571 (316 Ti)
Span ≥ 0.4 bar [160 inH 2 O]NiCr alloy (Inconel)
BellowsStainless steel 1.4571 (316 Ti)
Output signal
Signal type■ Variant 1: 4 …20mA, 2-wire, passive, per NAMUR NE 43 ■ Variant 2: 4 ... 20 mA, 2-wire, for hazardous areas ■ Variant 3: 0 ... 20 mA, 3-wire ■ Variant 4: 0 ... 10 V, 3-wire
Auxiliary power
Supply voltageVariant 1, 3U B = DC >12 ...≤ 30V
Variant 2U B = DC >14 ...≤ 30V
Variant 4U B = DC >15 ...≤ 30V
Permissible residual ripple of supply voltage< 10 %ss
LoadVariant 1, 2, 3R A ≤ (Supply voltage - 12 V)/0.02 A, max.600Ω
Variant 4R A = 100 kΩ
Operating conditions
Medium temperature range■ -20 ...+100 °C [-4 ...+212 °F] ■ -20 ...+120 °C [-4 ...+248 °F] ■ -20 ...+150 °C [-4 ...+284 °F]
Ambient temperature range■ -20 ...+60 °C [-4 ...+140 °F] ■ -40 ...+60 °C [-40 ...+140 °F] 1)
Storage temperature range-20 ...+60 °C [-4 ... 140 °F]
Pressure limitation
SteadyFull scale value
Fluctuating0.9 x full scale value
Ingress protection per IEC/EN 60529 2)■ IP54 ■ IP65 ■ IP66
DescriptionRegion
EU declaration of conformityEuropean Union
EMCDirective
LowVoltage Directive
RoHS directive
LogoDescriptionRegion
EU declaration of conformityEuropean Union
IECEx 1) Hazardous areas Gas Ex ia IIC T6/T5/T4 GbInternational
EAC EMCDirective LowVoltage DirectiveEurasian Economic Community
Ex Ukraine Hazardous areasUkraine
NEPSI Hazardous areasChina
PAC Kazakhstan Metrology, measurement technologyKazakhstan
Permission for commissioning PAC UzbekistanUzbekistan
Metrology, measurement technology
-CRN Safety (e.g. electr. safety, overpressure, ...)Canada
Certificates
Certificates■ 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, indication accuracy) ■ 3.1 inspection certificate per EN 10204 (e.g. indication accuracy)
Recommended calibration interval1 year (dependent on conditions of use)
Patent numberDescription
DE 202007019025, US 2010045366, CN 101438333Pointer measuring instrument with output signal 4 ...20mA
US Design D1051747S, CPC CN 01677074, DE Design 402022100171, EU Design 402022100171, IR Design DM/222416, EU 3D trademark 018659564WIKA blue identity design patent
Safety-related characteristic values (Ex)
Connection values
Max. voltage U iDC 30V
Max. current I i100mA
Max. power P i720mW
Effective internal capacitance C i11 nF
Effective internal inductance L iNegligible
NSSpan 1)Dimensions inmmWeight in
abcdD 1D 2eGh ±1Hkg
100 [4"]≤ 0.25 bar [100 inH 2 O]2559.5941401019917G¼161902.7
100 [4"]≥ 0.4 bar [160 inH 2 O]2559.594781019917G¼171871.9
160 [6"]≤ 0.25 bar [100 inH 2 O]256512414016115917G¼1911203.4
160 [6"]≥ 0.4 bar [160 inH 2 O]25651247816115917G¼2011172.4