AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
DPGT40 1
DPGT40
On order
WIKA · Pressure measurement · Family DELTA

Differential pressure gauge with output signal

With integrable working pressure indication (DELTA-trans)
Range
-12.5…1000 kPa
Output
4 ... 20 mA, 2-wire, passive
Accuracy
1.6
Protection
IP65
CECRNRoHSEMCII 2G Ex ia IIC T4/T5/T6 GbII 2D Ex ia IIIB T135°C DbEx ia IIC T4/T5/T6 GbEx ia IIIB T135°C DbGas II 2G Ex ia IIC T4/T5/T6 GbDust II 2D Ex ia IIIB T135℃ DbGas Ex ia IIC T4/T5/T6 GbDust Ex ia IIIB T135℃ Db
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The differential pressure gauges of the DELTA-line product family are primarily used for the monitoring and control of low differential pressures where there are high requirements in terms of one-sided overload and static pressure.

Typical markets for these products are the process heating technology, the heating, ventilation and air-conditioning industries, the water/wastewater industry, and machine building and plant construction. For these, the main function of the measuring instruments is the monitoring and control of filters, compressors and pumps.

Wherever a signal transmission is needed and, at the same time, a differential pressure has to be indicated locally, the DELTA-trans finds its use. An electronic angle encoder, proven in safety-critical automotive applications, determines the position of the pointer shaft - it is a non-contact sensor and completely free from wear and friction.

∙ 05/2021

Special features

  • Transmission of process values to the control room (e.g. 4 ... 20 mA)
  • Shatterproof window and robust aluminium or stainless steel measuring chamber for increased requirements
  • Optionally with approvals for hazardous areas
  • High ingress protection, IP65, for outdoor use and processes with high condensation
  • Low measuring range from 0 ... 160 mbar
Identification
ModelDPGT40
Product familyDELTA
SubcategoryDifferential pressure gauge with output signal
Measuring range
Pressure ranges0…160 mbar · -12.5…12.5 kPa · 0…0.016 MPa · 0…250 mbar · 0…16 kPa · 0…0.025 MPa · 0…400 mbar · 0…25 kPa · 0…0.04 MPa · 0…600 mbar · 0…40 kPa · 0…0.06 MPa · 0…1000 mbar · 0…60 kPa · 0…0.1 MPa · 0…0.16 bar · 0…160 kPa · 0…0.16 MPa · 0…0.25 bar · 0…250 kPa · 0…0.25 MPa · 0…0.4 bar · 0…400 kPa · 0…0.4 MPa · 0…0.6 bar · 0…600 kPa · 0…0.6 MPa · 0…1 bar · 0…1000 kPa · 0…1 MPa · 0…1.6 bar · 0…2.5 bar · 0…4 bar · 0…6 bar · 0…10 bar · 0…100 kPa · 0…5 psi · 0…15 psi · 0…25 psi · 0…40 psi · 0…60 psi · 0…0.16 kg/cm2 · 0…0.25 kg/cm2 · 0…0.4 kg/cm2 · 0…0.6 kg/cm2 · 0…1 kg/cm2 · 0…1.6 kg/cm2 · 0…2.5 kg/cm2 · 0…4 kg/cm2 · 0…6 kg/cm2 · 0…10 kg/cm2
Accuracy
Accuracy class1.6
Accuracy standardEN 837-1
Process conditions
Process connection
2 x G ¼, female thread, centre distance 26 mm2 x G ¼ B, male thread, centre distance 26 mm2 x bite-type fitting for pipe ∅ 6 mm2 x bite-type fitting for pipe ∅ 8 mm2 x bite-type fitting for pipe ∅ 10 mmG¼ female thread, centre distance 26mmG¼B male thread, centre distance 26mmbite-type fitting for pipe ∅6mmbite-type fitting for pipe ∅8mmbite-type fitting for pipe ∅10mm2xG1/4 female thread, centre distance 26mm2xG1/4B male thread, centre distance 26mm2x bite-type fitting for pipe Ø6mm2x bite-type fitting for pipe Ø8mm2x bite-type fitting for pipe Ø10mm
Process temperature−10…+90 °C
Electrical characteristics
Output signal4 ... 20 mA, 2-wire, passive · 4 ... 20 mA, 2-wire · 0 ... 20 mA, 3-wire · 0 ... 10 V, 3-wire · 4-20 mA · 0-20 mA · 0-10 V
Power supplyDC 12 ... 30 V
Electrical connectionAngular connector
Materials
Case materialaluminium, EN AC-AI Si9Cu3(Fe), black painted, aluminium, EN AC-AI Si9Cu3(Fe)
Wetted parts materialStainless steel 1.4571, Copper alloy, Steel, Aluminium, Al Si9Cu3(Fe), black painted, aluminium, Stainless steel
Sealing materialFPM/FKM, NBR
Operating environment
Ambient temperature−10…+70 °C
IP ratingIP65
Weight1.4 kg
Certifications and approvals
Certifications
CECRNRoHSEMC
Explosion protection
II 2G Ex ia IIC T4/T5/T6 GbII 2D Ex ia IIIB T135°C DbEx ia IIC T4/T5/T6 GbEx ia IIIB T135°C DbII 2G Ex ia IIC T4/T5/T6 Gb II 2D Ex ia IIIB T135°C DbIECEx Hazardous areas Gas Ex ia IIC T4/T5/T6 Gb Dust Ex ia IIIB T135°C DbGas II 2G Ex ia IIC T4/T5/T6 GbDust II 2D Ex ia IIIB T135℃ DbGas Ex ia IIC T4/T5/T6 GbDust Ex ia IIIB T135℃ Db
Additional details
Dial size100 mm
Datasheet languagesEN
Tables from datasheet
Measuring chamber materialWorking pressure indicationEx approval
AluminiumStainless steelWithoutØ 22mm
xxOption
xxOption
xxOption
Basic information
Nominal size
Differential pressure displayØ100mm
Working pressure indication■ Without ■ Ø22mm
Window
Non-Ex versionPlastic, with plug screw for zero point setting
Ex versionPlastic (zero point setting can only be carried out at the factory)
Case versionDisplay case, aluminium, EN AC-AI Si9Cu3(Fe); black painted
→Measuring chamber, see table 'Measuring element'
Measuring range
mbarpsi
0 ... 1600 ... 5
0 ... 2500 ... 15
0 ... 4000 ... 25
0 ... 6000 ... 40
0 ... 1,0000 ... 60
barkg/cm 2
0 ... 0.160 ... 0.16
0 ... 0.250 ... 0.25
0 ... 0.40 ... 0.4
0 ... 0.60 ... 0.6
0 ... 10 ... 1
0 ... 1.60 ... 1.6
0 ... 2.50 ... 2.5
0 ... 40 ... 4
0 ... 60 ... 6
0 ... 100 ... 10
Further details on: Measuring ranges
Type of pressureDifferential pressure
Special measuring rangesOther measuring ranges on request
Unit■ bar ■ psi ■ mbar ■ kg/cm² ■ MPa ■ kPa
View all (11)
Process connection
Standard■ EN 837 ■ DIN EN ISO 8434-1
Size
EN 837■ 2 x G¼, female thread, centre distance26mm ■ 2 x G¼B,male thread, centre distance26mm
DIN EN ISO 8434-1■ 2 x bite-type fitting for pipe∅6mm ■ 2 x bite-type fitting for pipe∅8mm ■ 2 x bite-type fitting for pipe∅10mm
Measuring range
kPaMPa
-12.5 ... +12.50 ... 0.016
0 ... 160 ... 0.025
0 ... 250 ... 0.04
0 ... 400 ... 0.06
0 ... 600 ... 0.1
0 ... 1000 ... 0.16
0 ... 1600 ... 0.25
0 ... 2500 ... 0.4
0 ... 4000 ... 0.6
0 ... 6000 ... 1
0 ... 1,000
LogoDescriptionCountry
EU declaration of conformityEuropean Union
EMCdirective
-CRN Safety (e.g. electr. safety, overpressure, ...)Canada
LogoDescriptionCountry
EU declaration of conformityEuropean Union
ATEX directive Hazardous areas
Gas DustII 2G Ex ia IIC T4/T5/T6 Gb II 2D Ex ia IIIB T135°C Db
IECEx Hazardous areas Gas Ex ia IIC T4/T5/T6 Gb Dust Ex ia IIIB T135°C DbInternational
EACEurasian Economic Community
EMCdirective
UkrSEPRO Metrology, measurement technologyUkraine
Ex Ukraine Hazardous areasUkraine
Uzstandard Metrology, measurement technologyUzbekistan
GOST Metrology, measurement technologyRussia
KazInMetr Metrology, measurement technologyKazakhstan
-MTSCHS Permission for commissioningKazakhstan
BelGIM Metrology, measurement technologyBelarus
Certificates
Certificates■ 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, indication accuracy) ■ 3.1 inspection certificate per EN 10204 (e.g. indication accuracy)
Recommended recalibration interval1 year (dependent on conditions of use)
Safety-related characteristic values (Ex)
Terminals'I+' and 'GND'
Maximum voltage U iDC 30V
Maximum current l i100mA
Maximum power P i (gas)1W
Maximum power Pi (dust)
Ta ≤ +40 °C≤ 750mW
Ta ≤ +60 °C≤ 650mW
Effective internal capacitance C i17.5 nF
Effective internal inductance L iNegligible
ModelDescriptionOrder number
-Panel mounting flange, aluminium14074004
Panel mounting flange, stainless steel14075088
910.17Sealings →see data sheet AC 09.08-
910.15Syphons →see data sheet AC 09.06-
IV3x4-way valve block, stainless steel →For dimensions see page 102043559
4-way valve block, brass →For dimensions see page 102043567
-Bite-type fittings for pipe diameters 6, 8 and10mmOn request