AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
DPGS40 1
DPGS40
On order
WIKA · Pressure measurement · Family DELTA-comb

Differential pressure gauge with micro switches

With integrated working pressure indication (DELTA-comb)
Range
-12.5…1000 kPa
Output
Microswitch · microswitch
Accuracy
2.5
Protection
IP65
RoHSCRNCEATEXIECExEACGOSTMTSCHSBelGIMEAC Hazardous areasII 2G Ex ia IIC T4/T5/T6 GbII 2D Ex ia IIIB T135°C DbEx ia IIC T4/T5/T6 GbEx ia IIIB T135°C DbEx Ukraine Hazardous areas
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The differential pressure gauges of the DELTA-line product family are primarily used for the monitoring and control of low differential pressures where there are high requirements in terms of one-sided overload and static pressure.

Typical markets for these products are the process heating technology, the heating, ventilation and air-conditioning industries, the water/wastewater industry, and machine building and plant construction. For these, the main function of the measuring instruments is the monitoring and control of filters, compressors and pumps.

Wherever circuits need to be switched safely dependent on a defined differential pressure, the DELTA-switch finds its use. As the pressure passes above or below a defined set point, the switching operation is triggered.

∙ 05/2021

Special features

  • With one or two adjustable microswitches
  • Shatterproof window and robust aluminium or stainless steel measuring chamber for increased requirements
  • Optionally with approvals for hazardous areas
  • High ingress protection, IP65, for outdoor use and processes with high condensation
  • Low measuring range from 0 ... 250 mbar
Identification
ModelDPGS40
Product familyDELTA-comb
SubcategoryDifferential pressure gauge with microswitches
Measuring range
Pressure ranges0…250 mbar · 0…400 mbar · 0…600 mbar · 0…1000 mbar · 0…0.25 bar · 0…0.4 bar · 0…0.6 bar · 0…1 bar · 0…1.6 bar · 0…2.5 bar · 0…4 bar · 0…6 bar · 0…10 bar · -12.5…12.5 kPa · 0…25 kPa · 0…40 kPa · 0…60 kPa · 0…100 kPa · 0…160 kPa · 0…250 kPa · 0…400 kPa · 0…600 kPa · 0…1000 kPa · 0…0.025 MPa · 0…0.04 MPa · 0…0.06 MPa · 0…0.1 MPa · 0…0.16 MPa · 0…0.25 MPa · 0…0.4 MPa · 0…0.6 MPa · 0…1 MPa
Accuracy
Accuracy class2.5
Accuracy standardEN 837-1
Process conditions
Process connection
G ¼ female threadG ¼ B male threadbite-type fitting for pipe ∅ 6 mmbite-type fitting for pipe ∅ 8 mmbite-type fitting for pipe ∅ 10 mmG 1/4, female threadG 1/4 B, male threadG 1/4 female
Process temperature−10…+90 °C
Electrical characteristics
Output signalMicroswitch
Electrical connectioncable gland M20 x 1.5 with 1 m cable, flying leads
Switching functionChange-over contact
Switching contacts1
Materials
Case materialaluminium, stainless steel, Aluminium, EN AC-AI Si9Cu3(Fe), Stainless steel 1.4571, Aluminium, EN AC-AI Si9Cu3(Fe), black painted
Wetted parts materialStainless steel 1.4571, Copper alloy, Steel, Aluminium, EN AC–Al Si9Cu3(Fe), Aluminium, Al Si9Cu3(Fe), Stainless steel, Aluminium, EN AC-AI Si9Cu3(Fe), black painted
Sealing materialFPM/FKM, NBR
Operating environment
Ambient temperature−10…+70 °C
IP ratingIP65
Weight1.4 kg
Certifications and approvals
Certifications
RoHSCRNCEATEXIECExEACGOSTMTSCHSBelGIM
Explosion protection
EAC Hazardous areasII 2G Ex ia IIC T4/T5/T6 GbII 2D Ex ia IIIB T135°C DbEx ia IIC T4/T5/T6 GbEx ia IIIB T135°C DbIECEx Hazardous areas Gas Ex ia IIC T4/T5/T6 Gb Dust Ex ia IIIB T135°C DbEx Ukraine Hazardous areasMTSCHS Permission for commissioningATEX directive Hazardous areas Gas II 2G Ex ia IIC T4/T5/T6 Gb Dust II 2D Ex ia IIIB T135℃ DbIECEx Hazardous areas Gas Ex ia IIC T4/T5/T6 Gb Dust Ex ia IIIB T135℃ Db
Additional details
Dial size100 mm
Datasheet languagesEN
Tables from datasheet
Measuring chamber materialWorking pressure indicationEx approval
AluminiumStainless steelWithoutØ 22mm
xxOption
xxOption
xxOption
Basic information
Nominal size
Differential pressure displayØ100mm
Working pressure indication■ Without ■ Ø22mm
Window
Non-Ex versionPlastic, with plug screw for switch point setting
Ex versionPlastic (switch point setting can only be carried out at the factory)
Case versionDisplay case, aluminium, EN AC-AI Si9Cu3(Fe); black painted
→Measuring chamber, see table 'Measuring element'
Measuring range
mbarpsi
0 ... 2500 ... 15
0 ... 4000 ... 25
0 ... 6000 ... 40
0 ... 1,0000 ... 60
barkg/cm 2
0 ... 0.250 ... 0.25
0 ... 0.40 ... 0.4
0 ... 0.60 ... 0.6
0 ... 10 ... 1
0 ... 1.60 ... 1.6
0 ... 2.50 ... 2.5
0 ... 40 ... 4
0 ... 60 ... 6
0 ... 100 ... 10
Measuring range
kPaMPa
-12.5 ... +12.50 ... 0.025
0 ... 250 ... 0.04
0 ... 400 ... 0.06
0 ... 600 ... 0.1
0 ... 1000 ... 0.16
0 ... 1600 ... 0.25
0 ... 2500 ... 0.4
0 ... 4000 ... 0.6
0 ... 6000 ... 1
0 ... 1,000
View all (10)
Operating conditions
Medium temperature-10 ...+90 °C [14 ... 194 °F]
Ambient temperature
Non-Ex version-10 ...+70 °C [14 ... 150 °F]
Ex version-10 ...+60 °C [14 ... 140 °F]
Storage temperature-20 ...+60 °C [-4 ...+140 °F]
Pressure limitation
SteadyEnd value of measuring range
Fluctuating0.9 x end value of measuring range
Overload safetyMax. 25 bar On one, both and alternatingly on the ⊕and ⊖sides
Ingress protection per IEC/EN 60529IP65
LogoDescriptionCountry
EU declaration of conformityEuropean Union
Pressure equipment directive
-RoHS directive CRNCanada
LogoDescriptionCountry
EU declaration of conformityEuropean Union
IECEx Hazardous areas Gas Ex ia IIC T4/T5/T6 Gb Dust Ex ia IIIB T135°C DbInternational
EAC Hazardous areasEurasian Economic Community
UkrSEPRO Metrology, measurement technologyUkraine
Ex Ukraine Hazardous areasUkraine
Uzstandard Metrology, measurement technologyUzbekistan
GOST Metrology, measurement technologyRussia
KazInMetr Metrology, measurement technologyKazakhstan
-MTSCHS Permission for commissioningKazakhstan
BelGIM Metrology, measurement technologyBelarus
Certificates
Certificates■ 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, indication accuracy) ■ 3.1 inspection certificate per EN 10204 (e.g. indication accuracy)
Recommended recalibration interval1 year (dependent on conditions of use)
Safety-related characteristic values (Ex)
Terminals
Switch A'1' / '4' / '2'
Switch B'3' / '6' / '5'
Maximum voltage U iDC 30V
Maximum current l i100mA
Maximum power P i (gas)1W
Maximum power Pi (dust)
Ta ≤ +40 °C≤ 750mW
Ta ≤ +60 °C≤ 650mW
Effective internal capacitance C iNegligible
Effective internal inductance L iNegligible
ModelDescriptionOrder number
-Panel mounting flange, aluminium14074004
Panel mounting flange, stainless steel14075088
910.17Sealings →see data sheet AC 09.08-
910.15Syphons →see data sheet AC 09.06-
IV3x4-way valve block, stainless steel →For dimensions see page 102043559
4-way valve block, brass →For dimensions see page 102043567
-Bite-type fittings for pipe diameters 6, 8 and10mmOn request