WIKA · Pressure measurement · Family DMS
Diaphragm monitoring system with flange connection
For the chemical and petrochemical industries
Range
-1…40 bar
Output
PROFIBUS PA · 4-20 mA
Accuracy
≤ 0.1 % of span
Protection
IP65
NACE MR 1705NACE MR 103EN 10204 2.2EN 10204 3.1
Price
On request
Depends on configuration
Description
The WIKA combination of diaphragm seal, pressure measuring instrument and monitoring element is ideally suited for the harshest measuring tasks. The system can withstand aggressive or hot media.
The patented diaphragm monitoring has been designed specifically for the highest safety requirements in the chemical and petrochemical industries.
On the double-diaphragm system a second, internal diaphragm in the pressure measuring instrument ensures the reliable separation of the environment and the process in the event of a diaphragm rupture. The measuring function of the overall system remains unrestricted, nevertheless it must be replaced immediately.
Special features
- Double-diaphragm system to ensure the separation of the process and the pressure measuring instrument
- Process connection with flange to provide for direct threaded connection
- All welded design with flush diaphragm
- Wetted parts from Hastelloy
Identification
| Model | DMS27 |
| Product family | DMS |
| Subcategory | Diaphragm monitoring system |
Measuring range
| Pressure ranges | 0…2.5 bar · 0…4 bar · 0…6 bar · 0…10 bar · 0…16 bar · 0…25 bar · -1…1.6 bar · -1…3 bar · -1…5 bar · -1…10 bar · -1…15 bar · 0…40 bar · -1…25 bar |
Accuracy
| Accuracy class | ≤ 0.1 % of span |
| Accuracy standard | IEC 61298-2 |
| Safety integrity level (SIL) | SIL qualified (option for IPT-20) |
Process conditions
| Process connection | Flange connection DN 2" Class 150, ASME B16.5Flange DN 2" Class 150 ASME B16.5 |
| Process temperature | −10…+120 °C |
Electrical characteristics
| Output signal | PROFIBUS PA · 4-20 mA · HART · FOUNDATION Fieldbus · FOUNDATION™ Fieldbus · 4-20mA with HART |
| Power supply | DC 10 ... 30 V |
| Electrical connection | Angular connector DIN EN 175301-803 A |
Materials
| Case material | Stainless steel 316L/1.4404, Stainless steel, Aluminium die-casting AlSi10Mg, PA 6, Aluminium die-casting AlSi10Mg, powder-coated, Aluminium die-casting AlSi10Mg, powder-coated on PE basis |
| Wetted parts material | Hastelloy C276 2.4819; UNS N10276 |
| Sealing material | PA 6 |
Operating environment
| Ambient temperature | +10…+40 °C |
| IP rating | IP65 |
Certifications and approvals
| Certifications | NACE MR 1705NACE MR 103EN 10204 2.2EN 10204 3.1 |
Additional details
| Datasheet languages | EN |
Tables from datasheet
Diaphragm seal system
| Design | Process transmitter mounted to a diaphragm seal with flange connection, welded |
|---|---|
| Measuring range | |
| Gauge pressure | 0 ... 2.5 bar [0 ... 40 psi] 0 ... 4 bar [0 ... 60 psi] 0 ... 6 bar [0 ... 100 psi] 0 ... 10 bar [0 ... 150 psi] 0 ... 16 bar [0 ... 250 psi] 0 ... 25 bar [0 ... 400 psi] 0 ... 40 bar [0 ... 600 psi] -1 ... +1.6 bar [-30 inHg ...+25 psi] -1 ...+3 bar [-30 inHg ...+45 psi] |
| Vacuum 1) | -1 ...+5 bar [-30 inHg ...+70 psi] -1 ...+10 bar [-30 inHg ...+145 psi] -1 ...+15 bar [-30 inHg ...+220 psi] -1 ...+25 bar [-30 inHg ...+360 psi] -10 ...+120 °C [-50 ...+248 °F] 10 ... 40 °C [50 ... 104 °F] |
| Permissible temperature range Medium Ambient Storage | 10 ... 60 °C [50 ... 140 °F] |
| Ingress protection per IEC/EN 60529 | IP65 |
| Material 2) wetted | Diaphragm: Hastelloy C276 2.4819;UNS N10276 Diaphragm seal: Hastelloy C276 2.4819;UNS N10276 |
| Mounting type | Direct mounting |
| Level of cleanliness of wetted parts | Oil and grease free per ASTM G93-03 level FWIKA standard (< 1,000 mg/m²) |
| System fill fluid | KN 21 halocarbon |
| Monitoring element 3) | Absolute pressure sensor (Model IS-3) |
|---|---|
| Current output | 4 ... 20 mA(2-Leiter) |
| Signal behaviour | 0 bar abs. →Outer diaphragm intact Signal:4mA ≥ 0,8 bar abs. →Outer diaphragm defective Signal: > 4 mA(depending on the pressure measuring range of the absolute pressure sensor) |
| Power supply | DC 10 ...30V |
| Permissible load in Ω | ≤ (power supply - 10 V) / 0.02 A - (cable length in mx0.14 Ω) |
| Material Case Wetted parts 4) Angular connector DIN EN 175301-803 A | Stainless steel Hastelloy PA6 |
| Ingress protection per IEC/EN 60529 | IP65 |
Pressure measuring instrument: Process transmitter model IPT-20
| Output signal | 4 ...20mA 4 ... 20 mAwith a superimposed HART ® communication signal (option: SIL qualification) HART ® specification: 7.3 FOUNDATION™ Fieldbus PROFIBUS ® PA |
|---|---|
| Load in Ω | (U B - U Bmin ) / 0.023 A U B = Applied power supply (see table 'Power supply') U Bmin = Minimum power supply (see table 'Power supply') |
| Accuracy at room temperature 1) | Measuring ranges ≤ 40 bar: ≤ 0.1 %of span |
| Material (non-wetted) Case Sensor | Double chamber case, aluminium die-casting AlSi10Mg, powder-coated on PE basis Stainless steel 316L/1.4404 |
| Display | LC display with backlighting, can be fitted on the top or on the side |
| Ingress protection per IEC/EN 60529 | IP66 / IP67 |
Industry
Oil & Gas
Chemical/petrochemical industry, oil/gas industries · Pressure/vacuum measurement on pipelines or vessels
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →