Compact differential pressure switch
Description
These high-quality pressure switches have been developed especially for safety-critical applications. The high quality of the products and manufacturing in accordance with ISO 9001 ensure reliable monitoring of your plant. In production, the switches are traced by quality assurance software at every step and subsequently are 100 % tested.
In order to ensure as flexible operation as possible, the pressure switches are fitted with micro switches, which enable the switching of an electrical load of up to AC 250 V, 20 A directly.
For lower switching power ratings, such as for PLC applications, argon gas-filled micro switches with gold-plated contacts can be selected.
Special features
- No power supply needed for switching of electrical loads
- Robust switch enclosure from aluminium alloy or stainless steel 316L, IP66, NEMA 4X
- Setting ranges from 0 ... 160 mbar to 0 ... 40 bar with high static and high one-sided pressure up to 250 bar
- Intrinsic safety Ex ia available
- 1 set point, SPDT or DPDT, high switching power up to AC 250 V, 15 A
| Model | DC, DCC |
| Subcategory | Differential pressure switch |
| Pressure ranges | 0…40 bar · -1.25…1.25 bar · -2…2 bar · -3…3 bar · -5…5 bar · -8…8 bar · -12.5…12.5 bar · 0…160 mbar · 0…0.16 bar · 0…0.25 bar · 0…0.4 bar · 0…0.6 bar · 0…1 bar · 0…1.6 bar · 0…2.5 bar · 0…4 bar · 0…6 bar · 0…10 bar · 0…16 bar · 0…25 bar · -0.04…0.12 bar · -0.06…0.19 bar · -0.2…0.2 bar · -0.3…0.3 bar · -0.5…0.5 bar · 0…250 mbar · 0…400 mbar · 0…600 mbar · -40…120 mbar · -60…190 mbar · -200…200 mbar · -300…300 mbar · -500…500 mbar |
| Accuracy standard | IEC 61298-2:2008 |
| Safety integrity level (SIL) | SIL 2 per IEC 61508 |
| Process connection | ¼ NPT femaleG ¼ A maleG ¼ femaleM20 x 1.5 male½ NPT maleG ½ A male½ NPT female½ NPTG ½ A |
| Process temperature | −30…+85 °C |
| Electrical connection | ½ NPT female |
| Switching function | SPDT or DPDT |
| Switching contacts | 1 |
| Case material | Aluminium alloy, Stainless steel 316L |
| Wetted parts material | AISI 316, AISI 316L, AISI 304, Inconel 718, Monel 400, Monel®400, Inconel®718, Aluminium alloy (EN AW-5082) |
| Sealing material | NBR |
| Ambient temperature | −30…+85 °C |
| IP rating | IP66 |
| Weight | 5.4 kg |
| Certifications | RoHSNACECEATEXIECExEACEx-UkraineCCCKOSHA |
| Explosion protection | Ex ia I MaEx ia IIC T6/T4 GaEx ia IIIC T85/T135 Da |
| Datasheet languages | EN, DE |
| Contact version | Electrical rating (resistive load) | Suitable for option | ||
|---|---|---|---|---|
| AC | DC | Ex ia | ||
| A | 1 x SPDT, silver | 250 V, 15 A | 24 V, 2 A, 125 V, 0.5 A, 220 V, 0.25 A | No |
| B | 1 x SPDT, silver, hermetically sealed, argon gas filling 2) | 250 V, 15 A | 24 V, 2 A, 220 V, 0.5 A | Yes |
| C | 1 x SPDT, gold-plated, hermetically sealed, argon gas filling 2) | 125 V, 1 A | 24 V, 0.5 A | Yes |
| G | 1 x DPDT, silver | 250 V, 1 A | 24 V, 0.5 A | No |
| Voltage U i | DC 30V |
|---|---|
| Current l i | 100mA |
| Power P i | 0.75W |
| Internal capacitance C i | 0 μF |
| Internal inductance L i | 0mH |
| Setting range | Stainless steel version | NACE version (option) 1) | Monel version (option) | |||
|---|---|---|---|---|---|---|
| Diaphragm | Process con- nection | Diaphragm | Process con- nection | Diaphragm | Process connection | |
| 0 ... 160 mbar | AISI 316 | AISI 316L | Monel ® 400 | AISI 316L | Monel ® 400 | |
| 0 ... 250 mbar | ||||||
| 0 ... 400 mbar | ||||||
| 0 ... 600 mbar | ||||||
| 0 ... 1 bar | ||||||
| 0 ... 2.5 bar | ||||||
| 0 ... 4 bar | AISI 304 | |||||
| 0 ... 6 bar | ||||||
| 0 ... 10 bar | ||||||
| 0 ... 16 bar | Inconel ® 718 | Inconel ® 718 | - | |||
| 0 ... 25 bar | ||||||
| 0 ... 40 bar |
| Setting range | Diaphragm | Process con- nection |
|---|---|---|
| 0 ... 160 mbar | Inconel ® 718 | Aluminium alloy (EN AW-5082 per EN 573-3) |
| 0 ... 250 mbar | ||
| 0 ... 400 mbar | ||
| 0 ... 600 mbar | ||
| 0 ... 1 bar | ||
| 0 ... 1.6 bar | ||
| 0 ... 2.5 bar | ||
| 0 ... 4 bar | ||
| 0 ... 6 bar |
View all (7)
| Δp-cell | Setting range | Fixed dead band for contact version | Static / One-sided pressure | |
|---|---|---|---|---|
| in bar | 1 contact A, B, C in mbar | 1 contact G in mbar | in bar | |
| L | 0 ... 0.16 | ≤ 6 | ≤ 12 | ≤ 40, ≤ 100 or ≤ 160 |
| 0 ...0.25 | ≤ 8 | ≤ 20 | ||
| H | 0 ... 0.4 | ≤ 20 | ≤ 40 | |
| 0 ... 0.6 | ≤ 25 | ≤ 50 | ||
| 0 ... 1 | ≤ 40 | ≤ 80 | ||
| 0 ... 2.5 | ≤ 70 | ≤ 170 | ≤ 40, ≤ 100, ≤ 160 or ≤ 250 | |
| 0 ... 4 | ≤ 120 | ≤ 200 | ||
| 0 ... 6 | ≤ 180 | ≤ 250 | ||
| 0 ... 10 | ≤ 300 | ≤ 400 | ||
| 0 ... 16 | ≤ 480 | ≤ 600 | ||
| 0 ... 25 | ≤ 700 | ≤ 1,000 | ||
| V | 0 ... 40 | ≤ 1,200 | ≤ 1,800 | ≤ 40, ≤ 100 or ≤ 160 |
| Δp-cell | Setting range | Fixed dead band for contact version | Static / One-sided pressure | |
|---|---|---|---|---|
| in bar | 1 contact A, B, C in mbar | 1 contact G in mbar | in bar | |
| L | 0 ... 0.25 | ≤ 5 | ≤ 10 | ≤ 25 |
| H | 0 ... 1 | ≤ 30 | ≤ 50 | |
| 0 ... 1.6 | ≤ 50 | ≤ 110 | ||
| 0 ... 2.5 | ≤ 80 | ≤ 170 | ||
| 0 ... 4 | ≤ 120 | ≤ 200 | ||
| 0 ... 6 | ≤ 120 | ≤ 200 |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity ■ Pressure equipment directive ■ Low voltage directive ■ RoHS directive ■ ATEX directive 1) (option) IM1 II1GD | European Community | |
| IECEx 1) (option) Ex ia I Ma Ex ia IIC T6/T4 2) Ga Ex ia IIIC T85/T135 2) Da | IECEx member states | |
| EAC (option) Hazardous areas | Eurasian Economic Community | |
| Ex-Ukraine (option) Hazardous areas | Ukraine | |
| CCC (option) Hazardous areas | China | |
| KOSHA (option) Hazardous areas | South Korea |