AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
DA, DA10 1
DA, DA10
On order
WIKA · Pressure measurement · Family DA

Differential pressure switch

Differential pressure switch with flameproof enclosure Ex d for safety-critical applications in chemical, petrochemical, oil and gas industries, power generation, water/wastewater, and mining. Suitable for gaseous, liquid, and aggressive media.
Range
-12.5…40 bar
Accuracy
≤ 1 % of span
Protection
IP66
CERoHSATEXIECExEACEx-UkraineCCCKOSHAINMETROEx d IIC T6/T4 Ga/GbEx ta/tb IIIC T85/T135 Da/Db
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

These high-quality pressure switches have been developed especially for safety-critical applications. The high quality of the products and manufacturing in accordance with ISO 9001 ensure reliable monitoring of your plant. In production, the switches are traced by quality assurance software at every step and subsequently are 100 % tested.

In order to ensure as flexible operation as possible, the pressure switches are fitted with micro switches, which enable the switching of an electrical load of up to AC 250 V, 20 A directly.

For lower switching power ratings, such as for PLC applications, argon gas-filled micro switches with gold-plated contacts can be selected.

Special features

  • No power supply needed for switching of electrical loads
  • Robust switch enclosure from aluminium alloy, IP66, NEMA 4X
  • Setting ranges from 0 ... 16 mbar to 0 ... 40 bar with high static and high one-sided pressure up to 160 bar
  • Repeatability: ≤ 1 % of span
  • 1 or 2 independent set points, SPDT or DPDT, high switching power up to AC 250 V, 20 A
Identification
ModelDA, DA10
Product familyDA
SubcategoryDifferential pressure switch
Measuring range
Pressure ranges0…0.16 bar · 0…0.25 bar · 0…0.4 bar · 0…0.6 bar · 0…1 bar · 0…2.5 bar · 0…4 bar · 0…6 bar · 0…10 bar · 0…16 bar · 0…25 bar · 0…40 bar · 0…16 mbar · 0…25 mbar · 0…40 mbar · 0…60 mbar · -0.04…0.12 bar · -0.06…0.19 bar · -0.2…0.2 bar · -0.3…0.3 bar · -0.5…0.5 bar · -1.25…1.25 bar · -2…2 bar · -3…3 bar · -5…5 bar · -8…8 bar · -12.5…12.5 bar
Accuracy
Accuracy class≤ 1 % of span
Accuracy standardIEC 61298-2:2008
Safety integrity level (SIL)SIL 2 per IEC 61508
Process conditions
Process connection
¼ NPT female½ NPT maleG ½ A maleG ¼ A male½ NPT femaleG ¼ femaleM20 x 1.5 male
Process temperature−30…+85 °C
Electrical characteristics
Electrical connection½ NPT female
Switching functionSPDT or DPDT
Switching contacts2
Materials
Case materialAluminium alloy, copper-free, epoxy resin coated
Wetted parts materialAISI 316, AISI 316L, AISI 304, Monel 400, Inconel 718
Sealing materialNBR
Operating environment
Ambient temperature−30…+85 °C
IP ratingIP66
Weight7.2 kg
Certifications and approvals
Certifications
CERoHSATEXIECExEACEx-UkraineCCCKOSHAINMETRO
Explosion protection
Ex d IIC T6/T4 Ga/GbEx ta/tb IIIC T85/T135 Da/Db
Tables from datasheet
Contact versionElectrical rating (resistive load)
ACDC
UN1 x SPDT, silver250 V, 15 A24 V, 2 A, 125 V, 0.5 A, 220 V, 0.25 A
US1 x SPDT, silver, hermetically sealed, argon gas filling 2)250 V, 15 A24 V, 2 A, 220 V, 0.5 A
UO1 x SPDT, gold-plated, hermetically sealed, argon gas filling 2)125 V, 1 A24 V, 0.5 A
UG1 x SPDT, gold-plated125 V, 1 A24 V, 0.5 A
UR1 x SPDT, silver, adjustable dead band250 V, 20 A24 V, 2 A, 220 V, 0.5 A
DN2 x SPDT or 1 x DPDT, silver250 V, 15 A24 V, 2 A, 125 V, 0.5 A, 220 V, 0.25 A
DS2 x SPDT or 1 x DPDT, silver, hermetically sealed, argon gas filling 2)250 V, 15 A24 V, 2 A, 220 V, 0.5 A
DO2 x SPDT, or 1 x DPDT gold-plated, hermetically sealed, argon gas filling 2)125 V, 1 A24 V, 0.5 A
DG2 x SPDT or 1 x DPDT, gold-plated125 V, 1 A24 V, 0.5 A
Setting rangeStainless steel versionNACE 1) versionMonel version
DiaphragmProcess connectionDiaphragmProcess connectionDiaphragmProcess connection
16 mbarAISI 316AISI 316L---
25 mbar
40 mbar
60 mbar
160 mbarMonel ® 400AISI 316LMonel ® 400
250 mbar
400 mbar
600 mbar
1 bar
2.5 bar
4 barAISI 304
6 bar
10 bar
16 barInconel ® 718Inconel ® 718-
25 bar
40 bar
Δp-cellSetting rangeFixed dead band for contact versionAdjustable dead band for contact versionStatic / One-sided pressure
in bar1 contact UN, US, UO, UG in mbar2 contacts DN, DS, DO, DG in mbar1 contact UR in mbarin bar
L0 ... 0.16≤ 6≤ 625 ... 60≤ 40, ≤ 100 or ≤ 160
0 ...0.25≤ 8≤ 830 ... 80
-0 ... 0.4≤ 20≤ 2045 ... 120
0 ... 0.6≤ 25≤ 2580 ... 200
0 ... 1≤ 40≤ 40100 ... 270
0 ... 2.5≤ 70≤ 70260 ... 700
0 ... 4≤ 120≤ 120450 ... 1,150
0 ... 6≤ 180≤ 180600 ... 1,600
0 ... 10≤ 300≤ 3001,100 ... 2,800
0 ... 16≤ 480≤ 4801,600 ... 3,500
0 ... 25≤ 700≤ 7002,500 ... 5,500
V0 ... 40≤ 1,200≤ 1,200on request
Δp-cellSetting rangeFixed dead band for contact versionAdjustable dead band for contact versionStatic / One-sided pressure
in mbar1 contact UN, US, UO, UG in mbar2 contacts DN, DS, DO, DG in mbar1 contact UR in mbarin bar
-0 ... 16≤ 1.2≤ 1.6-≤ 10 2)
0 ... 25≤ 1.2≤ 1.64 ... 10≤ 10
0 ... 40≤ 1.6≤ 2.25 ... 14
0 ... 60≤ 2.5≤ 3.06 ... 18
View all (5)
LogoDescriptionCountry
EU declaration of conformity ■ Pressure equipment directive ■ Low voltage directive ■ RoHS directive ■ ATEX directive 1) II 1/2GDEuropean Community
IECEx 1) Ex d IIC T6/T4 2) Ga/Gb Ex d IIIC T85/T135 2) Da/DbIECEx member states
EAC (option) Hazardous areasEurasian Economic Community
Ex-Ukraine (option) Hazardous areasUkraine
CCC (option) Hazardous areasChina
KOSHA (option) Hazardous areasSouth Korea
INMETRO ■ Metrology, measurement technology ■ Hazardous areasBrazil