Hand-held thermometer
Description
The model CTH7000 hand-held thermometer is a high performance 2-channel thermometer for Pt100 and thermistor probes. The hand-held thermometer CTH7000 is a step up in measurement accuracy with a battery power.
The CTH7000 can handle all needs, with accuracies and resolutions normally associated with a bench top thermometer. Two inputs give direct temperatures from Pt100 or thermistor probes or can display the temperature difference between them. Measurements can be logged directly to memory or, use the USB port to control and data log with the PC.
The CTH7000 will display a statistical analysis of measurements, with average value, min and max values and standard deviation. Because the CTH7000 will display in ohms as well as temperature, it can even be used to calibrate
for further approvals see page 2
Hand-held thermometer model CTH7000
one probe against another. Most instruments require to enter calibrated probe data into memory to optimise measurement accuracy, which can mean a lot of data entering if you change probes regularly.
With ASL's SMART connector on the probes, you only need to store the data once - in the connector! The calibration data stays with the probe - permanently. The probe can even be used on another CTH7000 without any further action. The SMART connector saves time and reduces error. If you have existing calibrated or uncalibrated probes, no problem, CTH7000 automatically registers if a probe is SMART or normal.
Special features
- Temperature range: -200 ... +962 °C [-328 ... +1,764 °F]
- Stability: < 0.005 °C per year
- Dual inputs measuring platinum resistance thermometers (PRTs) and thermistors single or differential measurement
- High long-term stability
| Model | CTH7000 |
| Product family | CTH |
| Subcategory | hand-held thermometer |
| Temperature ranges | −200…+962 °C |
| Uncertainty | 0.015 K |
| Calibration type | temperature_bath |
| Output signal | RTD simulation · thermistor simulation |
| Ambient temperature | +0…+40 °C |
| Weight | 0.5 kg |
| Certifications | EACDKDDAkkSUKAS |
| Traceability | DKD · DAkkS · UKAS |
| Portable | Yes |
| Datasheet languages | EN, DE |
| Probe types | Pt100 and Pt25 resistance thermometers, NTC thermistors | |
|---|---|---|
| Measuring inputs | 2 | |
| Data entry format | ITS 90 and CVD for calibrated probes; or EN 60751 for uncalibrated probes | |
| Measuring ranges | ||
| Probe current | DC 1 mA(Pt100); Auto-select 1 mA, 10 µA and 3 µA for thermistors | |
| Temperature range | -200 ...+962 °C (-328 ... +1,764 °F), depending on thermometer probe | |
| Accuracy | ||
| Resistance thermometers 1) | 0.015 K | |
| NTC thermistors | 0 ...400Ω 400 Ω... 50 kΩ 50 ... 400 kΩ | ±0.006Ω ±0.01 %of reading ±0.02 %of reading |
| Digital indicator | |
|---|---|
| Display | |
| Screen | Large 4 1/2-digit two-line LC display with backlighting |
| Resolution | 0.001 °C |
| Functions | |
| Memory | approx. 8,000 values |
| Functions via key press | Statistical analysis: Min./Max. average and standard deviation, Hold, Zero, one-shot measurement, measurement log |
| Real-time clock | integrated clock with date |
| Voltage supply | |
| Power supply | Nickel-Metal Hydride (Ni-MH) rechargeable battery Charging socket built-in low battery indicator |
| Battery life | approx. 20 hours of operation |
| Permissible ambient conditions | |
| Operating temperature | 0 ... 40 °C (32 ... 104 °F) |
| Storage temperature | -20 ...+50 °C(-4 ...+122 °F) |
| Communication | |
| Interface | USB |
| Case | |
| Dimensions (L x D xW) | 232 x 97 x 53 mm(9.13 x 3.82 x 2.09 in) |
| Weight | 500 g (1.1 lbs) |
| Logo | Description | Country |
|---|---|---|
| EAC EMCdirective | Eurasian Economic Community | |
| KazInMetr Metrology, measurement technology | Kazakhstan | |
| - | MTSCHS Permission for commissioning | Kazakhstan |
| UkrSEPRO Metrology, measurement technology | Ukraine |
| Calibration | Standard: without certificate Option: 3.1 calibration certificate per DIN EN 10204 or DKD/DAkkS/UKAS calibration certificate |
|---|---|
| Recommended recalibration interval | 1 year (dependent on conditions of use) |
View all (8)
| Model | Dimensions | Temperature range | Detector length |
|---|---|---|---|
| CTP5000-250 | Pt100, d = 6 mm, l = 350mm Pt100, d = 0,24 in, l = 13,78 in | -50 ...+250 °C (-58 ..+482 °F) | 25mm (0.98 in) |
| CTP5000-450 | Pt100, d = 6 mm, l = 350mm Pt100, d = 0,24 in, l = 13,78 in | -80 ...+450 °C (-112 ..+842 °F) | 25mm (0.98 in) |
| CTP5000-651 | Pt100, d = 7,5 mm, l = 450 mm(125 mmGriff) Pt100, d = 0.30 in, l = 17,72 in (4,92 in Griff) | -189 ...+650 °C (-308 .. +1,202 °F) | 50mm (1.97 in) |
| Model | Dimensions | Temperature range | Detector length |
|---|---|---|---|
| CTP5000-200 | Pt100, d = 3 mm, l=30mm Pt100, d = 0.12 in, l = 1.18 in | -50 ...+200 °C (-58 ..+392 °F) | 6mm (0.24 in) |
| Model | Dimensions | Temperature range |
|---|---|---|
| CTP5000-K10 | NTC thermistor R25 = 10 KΩ, d = 4 mm, l = 300mm NTC thermistor R25 = 10 KΩ, d = 0.2 in, l = 11.8 in | -50 ...+125 °C (-58 ...+257 °F) |
| Key | Function |
|---|---|
| | Menu display |
| ☼ | Backlight |
| ▲ | Up arrow |
| ▼ | Down arrow |
| ◀ | Left arrow |
| ▶ | Right arrow |
| | Clear (view statistics) |
| | Enter |
| A/B | A/B channel select |
| 0 | Zero (offset) reading |
| II | Hold reading |
| ON/OFF |
Couldn't find the answer in the documentation? An engineer will reply within a business day.