WIKA · Calibration technology · Family CPT
Precision pressure transducer
Precision pressure transducer, premium version, model CPT9000, with high accuracy and multiple communication interfaces for calibration and critical applications.
Range
-1…401 bar
Output
temperature output
Protection
IP67
RoHSUKCACE
Price
On request
Depends on configuration
Description
The model CPT9000 precision pressure transducer is designed to excel in performance and value. With an accuracy down to 0.008 % IS-33, a temperature compensation range of 0 ... 50 °C [32 ... 122 °F], calibration interval of 365 days and selectable ranges from 25 mbar ... 400 bar [10 inH₂O ... 6,000 psi], the CPT9000 stands alone in performance and value in the high-accuracy pressure transducer market. The CPT9000 is at the top of Mensors high-accuracy pressure transducer line.
Special features
- Accuracy up to: 0.008 % IS-33
- Measuring range: 0 ... 25 mbar up to 401 bar [0 ... 10 inH 2 O up to 6,015 psi]
- Temperature compensation: 0 ... 50 °C [32 ... 122 °F]
- USB, RS-232 or RS-485 communication
- Temperature output
Identification
| Model | CPT9000 |
| Product family | CPT |
| Subcategory | pressure transducer |
Measuring range
| Pressure ranges | 0…100 bar · 0…0.025 bar · -1…100 bar · -1…400 bar · 0.552…1.172 bar · 0…401 bar · 100…400 bar · -0.013…0.013 bar · 0…101 bar · 0…1 bar · 0…400 bar · -1…10 bar · -12.5…12.5 mbar · 0…0.35 bar · 0…25 mbar |
| Temperature ranges | +0…+50 °C · −40…+85 °C |
Accuracy
| Uncertainty | 0.008 % of reading |
Process conditions
| Medium | gas |
| Calibration type | electronic |
Electrical characteristics
| Output signal | temperature output |
Operating environment
| Ambient temperature | −40…+85 °C |
| IP rating | IP67 |
| Weight | 0.25 kg |
Certifications and approvals
| Certifications | RoHSUKCACE |
| Traceability | A2LA · DAkkS |
Additional details
| Datasheet languages | EN, DE, ES, FR, IT, NL, PL, PT, RO, SV, RU, EL, JA, ZH |
Tables from datasheet
Measuring range precision pressure transducer
| Accuracy 1) | 0.008 %IS-33 2) | 0.008 %IS-50 3) | 0.008 %Full Span |
|---|---|---|---|
| Measuring ranges | |||
| Gauge pressure 4) | 0 ... 1 to 0 ... 100 bar [0 ... 15 to 0 ... 1,500 psi] | 0 ...> 100 to 0 ... 400 bar [0 ...> 1,500 to 0 ... 6,000 psi] | 0 ... 25 mbar to 0 ...< 1 bar [0 ... 0.36 to 0 ...< 15 psi] |
| Bidirectional 4) 5) | -1 ... 10 to -1 ... 100 bar [-15 ... 145 to -15 ... 1,500 psi] | -1 ...> 100 to -1 ... 400 bar [-15 ...> 1,500 to -15 ... 6,000 psi] | -12.5 ... +12.5 mbar to -1 ...< 10 bar [-0.18 ... 0.18 to -15 ...< 145 psi] |
| Absolute pressure | 0 ... 1 to 0 ... 101 bar abs. [0 ... 15 to 0 ... 1,515 psi abs.] | 0 ...> 101 to 0 ... 401 bar abs. [0 ...> 1,515 to 0 ... 6,015 psi abs.] | 0 ... 350 mbar abs. to 0 ...< 1 bar abs. [0 ... 5 to 0 ...< 15 psi abs.] |
| As barometric reference, optional | |||
| Measuring range | 552 ... 1,172 mbar abs. [8 ... 17 psi abs.] | ||
| Accuracy 1) | 0.008 %of reading | ||
| Calibration interval | 365 days | ||
| Pressure units | 39 and 1 user-defined |
Basic information precision pressure transducer
| Display | ||
|---|---|---|
| Resolution | 100 ppb or better | |
| Boot-up time | ■ RS-232 ■ RS-485 | 750 ms |
| USB | 3.5 s | |
| Warm-up time | Approx. 15 min | |
| Voltage supply | ||
| Power supply | ■ RS-232 ■ RS-485 | DC 9 ...18V (DC 12V nominal) |
| USB | DC 3.0 ...5.25V (DC 5V nominal) Bus powered | |
| Power consumption | ■ RS-232 ■ RS-485 | < 26 mAat DC 12V ±5 %(0.40W max ) |
| USB | < 84 mAat DC 5V ±5 %(0.45W max ) | |
| Internal volume | ||
| Measure port | < 1 ml [< 1 cc] | |
| Reference port | Approx. 40 ml [40 cc] |
Basic information precision pressure transducer
| Case | |
|---|---|
| Orientation effects | Removable with a zero point correction |
| Dimensions | → See technical drawings |
| Weight | Approx. 250 g [0.55 lb] (depending on range) |
| Ingress protection | IP67 |
Communication
| Interface | ■ USB 2.0 ■ RS-232 ■ RS-485 |
|---|---|
| Baud rate (User-selectable) | ■ 9600 ■ 19200 ■ 38400 ■ 57600 baud (default setting) ■ 115200 |
| Command sets | ■ Mensor default command set ■ Mensor legacy command set |
| Measuring rate | 50 values/s: default - (adjustable ex-works) |
View all (11)
Pressure connection
| Connection | FSAE J514/JIC 4 | |
|---|---|---|
| Pressure port adapters | ■ Without ■ 6 mmtube fitting ■ ¼" tube fitting ■ ¼NPT, male thread ■ ⅛NPT, female thread ■ ¼BSP, male thread ■ ⅛BSP, female thread ■ 7/16-20 SAE, female thread | |
| Reference port | < 100 bar [< 1,500 psi] | 1/16" barb fitting |
| ■ > 100 bar [> 1,500 psi] ■ > 100 bar abs. [> 1,500 psi abs.] | Sealed relief valve 1) | |
| Wetted parts | Pressure ranges ≤ 350 mbar [≤ 5 psi] | ■ Stainless steel 316 ■ Silicon ■ Glass-filled resins ■ Epoxy |
| Pressure ranges > 350 mbar ... 100 bar [> 5 ... 1,500 psi] | ■ Stainless steel 316 | |
| Pressure ranges > 100 bar [> 1,500 psi] | ■ Stainless steel 316 ■ Fluorocarbon rubber | |
| Overpressure limit | 2 x proof, 3 x burst, static pressure < 3.45 bar [< 50 psi] |
Operating conditions
| Altitude | < 3,048 m[< 10,000 ft] | |
|---|---|---|
| Place of use | Indoor | |
| Operating temperature | -40 ...+85 °C [-40 ...+185 °F] | |
| Compensated temperature range | 0 ... 50 °C [32 ... 122 °F] | |
| Storage temperature range | -40 ...+85 °C [-40 ...+185 °F] | |
| Relative humidity, condensation | 0 ... 95 %r.h. (non-condensing) | |
| Permissible media | Pressure ranges ≤ 350 mbar [≤ 5 psi] | Clean, dry, non-corrosive gases |
| Pressure ranges > 350 mbar [> 5 psi] | Media compatible with the listed wetted parts | |
| Mounting position | ■ Horizontal ■ Vertical ■ Customised | |
| Pollution degree | 2 per EN 61010-1 | |
| EMC (HF field) | EN 61326-1 emission (group 1, class A) and immunity (industrial application) |
| Logo | Description Region |
|---|---|
| EU declaration of conformity | European Union |
| EMCdirective 1) EN 61326-1 emission (group 1, class A) and immunity (industrial application) | |
| RoHS directive | |
| UKCA | United Kingdom |
| Electromagnetic compatibility regulations | |
| Restriction of hazardous substances (RoHS) regulations |
Certificate
| Calibration 1) | ■ A2LA calibration certificate (traceable and accredited in accordance with ISO/IEC 17025) ■ DAkkS calibration certificate - absolute pressure (traceable and accredited in accordance with ISO/IEC 17025) ■ DAkkS calibration certificate - gauge pressure (traceable and accredited in accordance with ISO/IEC 17025) |
|---|---|
| Recommended calibration interval | 1 year (dependent on conditions of use) |
| Cal-Template (demo version) | Cal-Template (light version) | Cal-Template (full version) | Log-Template (full version) |
|---|---|---|---|
| Fully automatic calibration | Semi-automatic calibration | Fully automatic calibration | ■ Live measured value recording for a certain period of time with selectable interval, duration and start time ■ Creation of logger protocols with graphic and/or tabular representation of the measuring results in PDF format ■ Possibility of exporting measuring results as CSV file |
| Limitation to two measuring points | No limitation of the measuring points approached | ||
| ■ Creation of 3.1 inspection certificates per DIN EN 10204 ■ Calibration data can be exported to Excel ® template or XML file ■ Calibration of pressure measuring instruments | |||
| Ordering information for a single licence | |||
| Is available for a cost-free download | WIKA-CAL-LZ-Z-Z | WIKA-CAL-CZ-Z-Z | WIKA-CAL-ZZ-L-Z |
| Ordering information for a pair licence | |||
| Cal-Template (light version) together with Log-Template (full version) | WIKA-CAL-LZ-L-Z | ||
| Cal-Template (full version) together with Log-Template (full version) | WIKA-CAL-CZ-L-Z |
| CPT9000 / CPT6020 1) | Order code |
|---|---|
| CPX-A-T4 | |
| Power supply Via RS-232 interface cable Cable length: 1.5 m[4.9 ft] | -1- |
| Via RS-232 interface cable Cable length: 3.0 m[9.8 ft] | -3- |
| Via RS-232 interface cable Cable length: 5.0 m[16.4 ft] | -4- |
| Power supply Via RS-485 interface cable Cable length: 1.5 m[4.9 ft] | -2- |
| Via RS-485 interface cable Cable length: 3.0 m[9.8 ft] | -J- |
| Via RS-485 interface cable Cable length: 5.0 m[16.4 ft] | -K- |
| Adapter cable RS-232 to USB | -5- |
| RS-485 to USB | -6- |
| Legacy cable adapter RS-232 cable adapter For CPT6010 to CPT9000 or CPT6020 | -8- |
| RS-485 cable adapter For CPT6010 to CPT9000 or CPT6020 | -7- |
| Pressure adapter SAE J514/JIC 4, male thread to ¼BSP, male thread P max : 400 bar [6,000 psi] | -A- |
| Pressure adapter SAE J514/JIC 4, male thread to ⅛BSP, female thread P max : 400 bar [6,000 psi] | -B- |
| Pressure adapter SAE J514/JIC 4, male thread to 6 mmtube fitting P max : 400 bar [6,000 psi] | -C- |
| Pressure adapter SAE J514/JIC 4, male thread to 7/16-20 SAE, male thread P max : 400 bar [6,000 psi] | -D- |
| Pressure adapter SAE J514/JIC 4, male thread to ¼" tube fitting P max : 400 bar [6,000 psi] | -E- |
| Pressure adapter SAE J514/JIC 4, male thread to ¼NPT, male thread P max : 400 bar [6,000 psi] | -F- |
| Pressure adapter SAE J514/JIC 4, male thread to ⅛NPT, female thread P max : 400 bar [6,000 psi] | -S- |
| Pressure adapter SAE J514/JIC 4, male thread to G½BSP, male thread P max : 400 bar [6,000 psi] | -U- |
| Gasket-flare 50 pcs. gasket-flare 37° ¼" for J514/JIC 44 pressure port | -V- |
| Accessories for CPT9000 / CPT6020 1) | Order code | |
|---|---|---|
| Description | CPX-A-T4 | |
| Communication cable Shielded with flying leads Cable length: 1.5 m[4.9 ft] Shielded with flying leads Cable length: 3.0 m[9.8 ft] Shielded with flying leads Cable length: 5.0 m[16.4 ft] | -G- | |
| -H- | ||
| -I- | ||
| - | Transport case | -T- |
| Ordering information for your enquiry: | ||
| 1. Order code: CPX-A-T4 2. Option: | ⇓ [ ] |
Industry
Machinery
High-accuracy pressure monitoring · Pressure sensing in critical applications
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →