Precision pressure transducer, premium version, model CPT9000, with high accuracy and multiple communication interfaces for calibration and critical applications.
Range
-1…401 bar
Output
temperature output
Protection
IP67
RoHSUKCACE
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The model CPT9000 precision pressure transducer is designed to excel in performance and value. With an accuracy down to 0.008 % IS-33, a temperature compensation range of 0 ... 50 °C [32 ... 122 °F], calibration interval of 365 days and selectable ranges from 25 mbar ... 400 bar [10 inH₂O ... 6,000 psi], the CPT9000 stands alone in performance and value in the high-accuracy pressure transducer market. The CPT9000 is at the top of Mensors high-accuracy pressure transducer line.

Special features

  • Accuracy up to: 0.008 % IS-33
  • Measuring range: 0 ... 25 mbar up to 401 bar [0 ... 10 inH 2 O up to 6,015 psi]
  • Temperature compensation: 0 ... 50 °C [32 ... 122 °F]
  • USB, RS-232 or RS-485 communication
  • Temperature output
Identification
ModelCPT9000
Product familyCPT
Subcategorypressure transducer
Measuring range
Pressure ranges0…100 bar · 0…0.025 bar · -1…100 bar · -1…400 bar · 0.552…1.172 bar · 0…401 bar · 100…400 bar · -0.013…0.013 bar · 0…101 bar · 0…1 bar · 0…400 bar · -1…10 bar · -12.5…12.5 mbar · 0…0.35 bar · 0…25 mbar
Temperature ranges+0…+50 °C · −40…+85 °C
Accuracy
Uncertainty0.008 % of reading
Process conditions
Mediumgas
Calibration typeelectronic
Electrical characteristics
Output signaltemperature output
Operating environment
Ambient temperature−40…+85 °C
IP ratingIP67
Weight0.25 kg
Certifications and approvals
Certifications
RoHSUKCACE
TraceabilityA2LA · DAkkS
Additional details
Datasheet languagesEN, DE, ES, FR, IT, NL, PL, PT, RO, SV, RU, EL, JA, ZH
Tables from datasheet
Measuring range precision pressure transducer
Accuracy 1)0.008 %IS-33 2)0.008 %IS-50 3)0.008 %Full Span
Measuring ranges
Gauge pressure 4)0 ... 1 to 0 ... 100 bar [0 ... 15 to 0 ... 1,500 psi]0 ...> 100 to 0 ... 400 bar [0 ...> 1,500 to 0 ... 6,000 psi]0 ... 25 mbar to 0 ...< 1 bar [0 ... 0.36 to 0 ...< 15 psi]
Bidirectional 4) 5)-1 ... 10 to -1 ... 100 bar [-15 ... 145 to -15 ... 1,500 psi]-1 ...> 100 to -1 ... 400 bar [-15 ...> 1,500 to -15 ... 6,000 psi]-12.5 ... +12.5 mbar to -1 ...< 10 bar [-0.18 ... 0.18 to -15 ...< 145 psi]
Absolute pressure0 ... 1 to 0 ... 101 bar abs. [0 ... 15 to 0 ... 1,515 psi abs.]0 ...> 101 to 0 ... 401 bar abs. [0 ...> 1,515 to 0 ... 6,015 psi abs.]0 ... 350 mbar abs. to 0 ...< 1 bar abs. [0 ... 5 to 0 ...< 15 psi abs.]
As barometric reference, optional
Measuring range552 ... 1,172 mbar abs. [8 ... 17 psi abs.]
Accuracy 1)0.008 %of reading
Calibration interval365 days
Pressure units39 and 1 user-defined
Basic information precision pressure transducer
Display
Resolution100 ppb or better
Boot-up time■ RS-232 ■ RS-485750 ms
USB3.5 s
Warm-up timeApprox. 15 min
Voltage supply
Power supply■ RS-232 ■ RS-485DC 9 ...18V (DC 12V nominal)
USBDC 3.0 ...5.25V (DC 5V nominal) Bus powered
Power consumption■ RS-232 ■ RS-485< 26 mAat DC 12V ±5 %(0.40W max )
USB< 84 mAat DC 5V ±5 %(0.45W max )
Internal volume
Measure port< 1 ml [< 1 cc]
Reference portApprox. 40 ml [40 cc]
Basic information precision pressure transducer
Case
Orientation effectsRemovable with a zero point correction
Dimensions→ See technical drawings
WeightApprox. 250 g [0.55 lb] (depending on range)
Ingress protectionIP67
Communication
Interface■ USB 2.0 ■ RS-232 ■ RS-485
Baud rate (User-selectable)■ 9600 ■ 19200 ■ 38400 ■ 57600 baud (default setting) ■ 115200
Command sets■ Mensor default command set ■ Mensor legacy command set
Measuring rate50 values/s: default - (adjustable ex-works)
View all (11)
Pressure connection
ConnectionFSAE J514/JIC 4
Pressure port adapters■ Without ■ 6 mmtube fitting ■ ¼" tube fitting ■ ¼NPT, male thread ■ ⅛NPT, female thread ■ ¼BSP, male thread ■ ⅛BSP, female thread ■ 7/16-20 SAE, female thread
Reference port< 100 bar [< 1,500 psi]1/16" barb fitting
■ > 100 bar [> 1,500 psi] ■ > 100 bar abs. [> 1,500 psi abs.]Sealed relief valve 1)
Wetted partsPressure ranges ≤ 350 mbar [≤ 5 psi]■ Stainless steel 316 ■ Silicon ■ Glass-filled resins ■ Epoxy
Pressure ranges > 350 mbar ... 100 bar [> 5 ... 1,500 psi]■ Stainless steel 316
Pressure ranges > 100 bar [> 1,500 psi]■ Stainless steel 316 ■ Fluorocarbon rubber
Overpressure limit2 x proof, 3 x burst, static pressure < 3.45 bar [< 50 psi]
Operating conditions
Altitude< 3,048 m[< 10,000 ft]
Place of useIndoor
Operating temperature-40 ...+85 °C [-40 ...+185 °F]
Compensated temperature range0 ... 50 °C [32 ... 122 °F]
Storage temperature range-40 ...+85 °C [-40 ...+185 °F]
Relative humidity, condensation0 ... 95 %r.h. (non-condensing)
Permissible mediaPressure ranges ≤ 350 mbar [≤ 5 psi]Clean, dry, non-corrosive gases
Pressure ranges > 350 mbar [> 5 psi]Media compatible with the listed wetted parts
Mounting position■ Horizontal ■ Vertical ■ Customised
Pollution degree2 per EN 61010-1
EMC (HF field)EN 61326-1 emission (group 1, class A) and immunity (industrial application)
LogoDescription Region
EU declaration of conformityEuropean Union
EMCdirective 1) EN 61326-1 emission (group 1, class A) and immunity (industrial application)
RoHS directive
UKCAUnited Kingdom
Electromagnetic compatibility regulations
Restriction of hazardous substances (RoHS) regulations
Certificate
Calibration 1)■ A2LA calibration certificate (traceable and accredited in accordance with ISO/IEC 17025) ■ DAkkS calibration certificate - absolute pressure (traceable and accredited in accordance with ISO/IEC 17025) ■ DAkkS calibration certificate - gauge pressure (traceable and accredited in accordance with ISO/IEC 17025)
Recommended calibration interval1 year (dependent on conditions of use)
Cal-Template (demo version)Cal-Template (light version)Cal-Template (full version)Log-Template (full version)
Fully automatic calibrationSemi-automatic calibrationFully automatic calibration■ Live measured value recording for a certain period of time with selectable interval, duration and start time ■ Creation of logger protocols with graphic and/or tabular representation of the measuring results in PDF format ■ Possibility of exporting measuring results as CSV file
Limitation to two measuring pointsNo limitation of the measuring points approached
■ Creation of 3.1 inspection certificates per DIN EN 10204 ■ Calibration data can be exported to Excel ® template or XML file ■ Calibration of pressure measuring instruments
Ordering information for a single licence
Is available for a cost-free downloadWIKA-CAL-LZ-Z-ZWIKA-CAL-CZ-Z-ZWIKA-CAL-ZZ-L-Z
Ordering information for a pair licence
Cal-Template (light version) together with Log-Template (full version)WIKA-CAL-LZ-L-Z
Cal-Template (full version) together with Log-Template (full version)WIKA-CAL-CZ-L-Z
CPT9000 / CPT6020 1)Order code
CPX-A-T4
Power supply Via RS-232 interface cable Cable length: 1.5 m[4.9 ft]-1-
Via RS-232 interface cable Cable length: 3.0 m[9.8 ft]-3-
Via RS-232 interface cable Cable length: 5.0 m[16.4 ft]-4-
Power supply Via RS-485 interface cable Cable length: 1.5 m[4.9 ft]-2-
Via RS-485 interface cable Cable length: 3.0 m[9.8 ft]-J-
Via RS-485 interface cable Cable length: 5.0 m[16.4 ft]-K-
Adapter cable RS-232 to USB-5-
RS-485 to USB-6-
Legacy cable adapter RS-232 cable adapter For CPT6010 to CPT9000 or CPT6020-8-
RS-485 cable adapter For CPT6010 to CPT9000 or CPT6020-7-
Pressure adapter SAE J514/JIC 4, male thread to ¼BSP, male thread P max : 400 bar [6,000 psi]-A-
Pressure adapter SAE J514/JIC 4, male thread to ⅛BSP, female thread P max : 400 bar [6,000 psi]-B-
Pressure adapter SAE J514/JIC 4, male thread to 6 mmtube fitting P max : 400 bar [6,000 psi]-C-
Pressure adapter SAE J514/JIC 4, male thread to 7/16-20 SAE, male thread P max : 400 bar [6,000 psi]-D-
Pressure adapter SAE J514/JIC 4, male thread to ¼" tube fitting P max : 400 bar [6,000 psi]-E-
Pressure adapter SAE J514/JIC 4, male thread to ¼NPT, male thread P max : 400 bar [6,000 psi]-F-
Pressure adapter SAE J514/JIC 4, male thread to ⅛NPT, female thread P max : 400 bar [6,000 psi]-S-
Pressure adapter SAE J514/JIC 4, male thread to G½BSP, male thread P max : 400 bar [6,000 psi]-U-
Gasket-flare 50 pcs. gasket-flare 37° ¼" for J514/JIC 44 pressure port-V-
Accessories for CPT9000 / CPT6020 1)Order code
DescriptionCPX-A-T4
Communication cable Shielded with flying leads Cable length: 1.5 m[4.9 ft] Shielded with flying leads Cable length: 3.0 m[9.8 ft] Shielded with flying leads Cable length: 5.0 m[16.4 ft]-G-
-H-
-I-
-Transport case-T-
Ordering information for your enquiry:
1. Order code: CPX-A-T4 2. Option:⇓ [ ]