CPT6030 1
CPT6030
On order
WIKA · Calibration technology · Family CPT

Analogue pressure transducer

Analogue pressure transducer, basic version, with 4...20 mA output and high-accuracy pressure measurement for calibration and critical process applications.
Range
-1…1001 bar
Output
4 ... 20 mA · 4...20 mA
Protection
IP67
RoHSCEUKCAEMC
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The CPT6030 analogue pressure transducer is a self-contained pressure sensing instrument that provides high-accuracy pressure measurements with a 2-wire, 4 ... 20 mA output. This transducer incorporates a low-hysteresis silicon sensor with electronically compensated pressure linearity over the compensated temperature range. The CPT6030 is characterised over the full pressure and compensated temperature range to achieve 0.025 % FS accuracy. The metrological grade accuracy of 0.025 % FS includes linearity, hysteresis, repeatability drift and reference uncertainty over the temperature range. Also featured is an output which is updated at a rate of 21 readings per second (47 ms).

Special features

  • Metrological accuracy: 0.025 % FS on the 4 ... 20 mA output
  • Measuring range: 25 mbar ... 1,001 bar [10 inH 2 O ... 15,015 psi]
  • Voltage supply from DC 15 ... 28 V
  • Temperature compensation: -20 ... +75 °C [-4 ... +167 °F]
  • NAMUR NE43-compliant
Identification
ModelCPT6030
Product familyCPT
Subcategoryanalogue pressure transducer
Measuring range
Pressure ranges0…1000 bar · -1…1000 bar · 0…1001 bar · 552…1172 mbar · -0.013…0.013 bar · 0.552…1.172 bar · 0…25 mbar · -12.5…12.5 mbar · 0…350 mbar
Temperature ranges−20…+75 °C · −40…+85 °C
Accuracy
Uncertainty0.025 % FS
Process conditions
Mediumgases
Calibration typesignal
Electrical characteristics
Output signal4 ... 20 mA
Operating environment
Ambient temperature−40…+85 °C
IP ratingIP67
Weight0.25 kg
Certifications and approvals
Certifications
RoHSCEUKCAEMC
TraceabilityNIST · A2LA · DAkkS
Additional details
PortableYes
Datasheet languagesEN, DE, ES, FR, IT, NL, PL, PT, RO, SV, RU, EL, JA, ZH
Tables from datasheet
Measuring range analogue pressure transducer
Accuracy 1)0.025%FS 2)
Precision 3)0.015%FS
Measuring ranges
Gauge pressure 4)0 ... 25 mbar to 0 ... 1,000 bar [0 ... 0.36 to 0 ... 15,000 psi]
Bidirectional pressure 4) 5)-12.5 ... +12.5 mbar to -1 ... 1,000 bar [-0.18 ... +0.18 to -15 ... 15,000 psi]
Absolute pressure0 ... 350 mbar abs. to 0 ... 1,001 bar abs. [0 ... 5 to 0 ... 15,015 psi abs.]
Calibration interval365 days
CPT6030 as barometric reference
Measuring range■ 552 ... 1,172 mbar abs. ■ 8 ... 17 psi abs.
Accuracy 1) 2)0.025 %of reading
Calibration interval365 days
Basic information analogue pressure transducer
Warm-up timeApprox. 15 min
Pressure units39
Voltage supply
Power supplyDC 15 ...28V (DC 24V nominal)
Power consumption4 ... 20 mAdepending on pressure input (23 mA, 0.65W max )
Internal volume
Measure port< 1 ml [1 cc]
Reference portApprox. 45 ml [45 cc]
Case
Orientation effectsNegligible - completely removable with a zero point correction
Dimensions→ See technical drawings
WeightApprox. 250 g [0.55 lb] (depending on range)
Ingress protectionIP67
Communication
Output signal
Current (2-wire)4 ...20mA
InterfaceRS-232
Baud rate57600 baud
Command sets■ Mensor default command set ■ Mensor legacy command set
Measuring rate21 values/s
View all (10)
Pressure connection
ConnectionFSAE J514/JIC 4≤ 400 bar [≤ 6,000 psi]
Autoclave® F250C> 400 ... 1,000 bar [> 6,000 ... 15,000 psi]
Pressure adapters■ 6 mmtube fitting ■ ¼" tube fitting ■ ¼NPT, male thread ■ ⅛NPT, female thread ■ ¼BSP, male thread ■ ⅛BSP, female thread ■ 7/16-20 SAE, male threadOnly up to 400 bar [6,000 psi]
Reference port1/16" barb fitting≤ 100 bar [≤ 1,500 psi]
Sealed relief valve 1)■ > 100 bar [> 1,500 psi] ■ > 100 bar abs. [> 1,500 psi abs.]
Wetted partsPressure ranges ≤ 350 mbar [≤ 5 psi]■ Stainless steel 316 ■ Silicon ■ Glass-filled resins ■ Epoxy
Pressure ranges > 350 mbar ...≤ 100 bar [> 5 ...≤ 1,500 psi]Stainless steel 316
Pressure ranges > 100 bar [> 1,500 psi]■ Stainless steel 316 ■ Fluorocarbon rubber
Permissible pressure mediaPressure ranges ≤ 350 mbar [≤ 5 psi]Clean, dry, non-corrosive gases
Pressure ranges > 350 mbar [> 5 psi]Media compatible with the listed wetted parts
Overpressure limit2 x proof, 3 x burst, static pressure < 3.45 bar [< 50 psi]
Operating conditions
Altitude< 3,048 m[< 10,000 ft]
Place of useIndoor
Operating temperature-40 ...+85 °C [-40 ...+185 °F]
Compensated temperature range-20 ...+75 °C [-4 ...+167 °F]
Storage temperature range-40 ...+85 °C [-40 ...+185 °F]
Relative humidity, condensation0 ... 95 %r.h. (non-condensing)
Mounting position■ Horizontal ■ Vertical ■ Customised
Pollution degree2 per EN 61010-1
EMC (HF field)EN 61326-1 emission (group 1, class A) and immunity (industrial application)
LogoDescriptionRegion
EU declaration of conformityEuropean Union
EMCdirective 1) EN 61326-1 emission (group 1, class A) and immunity (industrial application)
Pressure Equipment Directive PS > 200 bar; module A, pressure accessory
UKCAUnited Kingdom
Electromagnetic compatibility regulations
Pressure equipment (safety) regulations
Restriction of hazardous substances (RoHS) regulations
Certificate
Calibration 1)■ 3.1 inspection certificate per DIN EN 10204 or NIST (factory calibration) ■ A2LA calibration certificate (traceable and accredited in accordance with ISO/IEC 17025) ■ DAkkS calibration certificate - absolute pressure (traceable and accredited in accordance with ISO/IEC 17025) ■ DAkkS calibration certificate - gauge pressure (traceable and accredited in accordance with ISO/IEC 17025)
Recommended calibration interval365 days (dependent on conditions of use)
Cal-Template (demo version)Cal-Template (light version)Cal-Template (full version)Log-Template (full version)
Fully automatic calibrationSemi-automatic calibrationFully automatic calibration■ Live measured value recording for a certain period of time with selectable interval, duration and start time ■ Creation of logger protocols with graphic and/or tabular representation of the measuring results in PDF format ■ Possibility of exporting measuring results as CSV file
Limitation to two measuring pointsNo limitation of the measuring points approached
■ Creation of 3.1 inspection certificates per DIN EN 10204 ■ Calibration data can be exported to Excel ® template or XML file ■ Calibration of pressure measuring instruments
Ordering information for a single licence
Is available for a cost-free downloadWIKA-CAL-LZ-Z-ZWIKA-CAL-CZ-Z-ZWIKA-CAL-ZZ-L-Z
Ordering information for a pair licence
Cal-Template (light version) together with Log-Template (full version)WIKA-CAL-LZ-L-Z
Cal-Template (full version) together with Log-Template (full version)WIKA-CAL-CZ-L-Z
Order code
CPX-A-T5
Calibration adapter For reference pressure transducers and current supply-1-
Pressure adapter SAE J514/JIC 4, male thread to ¼BSP, male thread P max : 400 bar [6,000 psi]-A-
Pressure adapter SAE J514/JIC 4, male thread to ⅛BSP, female thread P max : 400 bar [6,000 psi]-B-
Pressure adapter SAE J514/JIC 4, male thread to 6 mmtube fitting P max : 400 bar [6,000 psi]-C-
Pressure adapter SAE J514/JIC 4, male thread to 7/16-20 SAE, male thread P max : 400 bar [6,000 psi]-D-
Pressure adapter SAE J514/JIC 4, male thread to ¼" tube fitting P max : 400 bar [6,000 psi]-E-
Pressure adapter SAE J514/JIC 4, male thread to ¼NPT, male thread P max : 400 bar [6,000 psi]-F-
Pressure adapter SAE J514/JIC 4, male thread to ⅛NPT, female thread P max : 400 bar [6,000 psi]-G-
Pressure adapter SAE J514/JIC 4, male thread to G½BSP, male thread P max : 400 bar [6,000 psi]-H-
Gasket flare 50 gasket flare 37° ¼" for J514/JIC 44 pressure port-V-
Communication cable Shielded with flying leads Cable length: 1.5 m[4.9 ft]-2-
Shielded with flying leads Cable length: 3.0 m[9.8 ft]-3-
Shielded with flying leads Cable length: 5.0 m[16.4 ft]-4
Transport case-T-
1. Order code: CPX-A-T5⇓
[
]
2.
Option:
your enquiry:
forOrderinginformation