WIKA · Calibration technology · Family CPT
Precision pressure transducer
Precision pressure transducer, basic version for high-accuracy pressure monitoring in calibration technology and critical applications.
Range
-12.5…1172 mbar
Output
USB · RS-232
Protection
IP67
RoHSUKCAEU declaration of conformityCE
Price
On request
Depends on configuration
Description
The model CPT6020 precision pressure transducer is a self-contained pressure sensing instrument that provides high-accuracy pressure measurements. This transducer used a low-hysteresis silicon sensor with electronically compensated pressure linearity over the compensated temperature range.
The CPT6020 is characterised over the full pressure and temperature range to achieve 0.020 % FS accuracy. This specification includes linearity, hysteresis, repeatability and temperature errors. Also featured is an output which is updated at a rate of 50 readings per second (20 ms).
Special features
- Accuracy: 0.020 % FS
- Measuring range: 0 ... 25 mbar up to 1,001 bar [0 ... 10 inH 2 O up to 15,015 psi]
- Temperature compensation: 0 ... 50 °C [32 ... 122 °F]
- USB, RS-232 or RS-485 communication
- Rugged and compact design
Identification
| Model | CPT6020 |
| Product family | CPT |
| Subcategory | precision pressure transducer |
Measuring range
| Pressure ranges | 0…1000 bar · -1…1000 bar · 0…1001 bar · 552…1172 mbar · 0…25 mbar · -12.5…12.5 mbar · 0…350 mbar |
| Temperature ranges | +0…+50 °C · −40…+85 °C |
Accuracy
| Uncertainty | 0.020 % FS |
Process conditions
| Medium | gas |
| Calibration type | electronic |
Electrical characteristics
| Output signal | USB · RS-232 · RS-485 |
Operating environment
| Ambient temperature | −40…+85 °C |
| IP rating | IP67 |
| Weight | 0.25 kg |
Certifications and approvals
| Certifications | RoHSUKCAEU declaration of conformityCE |
| Traceability | A2LA · DAkkS |
Additional details
| Portable | Yes |
| Datasheet languages | EN, DE, ES, FR, IT, NL, PL, PT, RO, SV, RU, EL, JA, ZH |
Tables from datasheet
Measuring range precision pressure transducer
| Accuracy 1) | 0.020%FS |
|---|---|
| Measuring ranges | |
| Gauge pressure 2) | 0 ... 25 mbar to 0 ... 1,000 bar [0 ... 0.36 to 0 ...< 15,000 psi] |
| Bidirectional pressure 2) 3) | -12.5 ... +12.5 mbar to -1 ... 1,000 bar [-0.18 ... +0.18 to -15 ... 15,000 psi] |
| Absolute pressure | 0 ... 350 mbar abs. to 0 ... 1,001 bar abs. [0 ... 5 to 0 ... 15,015 psi abs.] |
| As barometric reference | |
| Measuring range | 552 ... 1,172 mbar abs. [8 ... 17 psi abs.] |
| Accuracy 1) | 0.020 %of reading |
| Calibration interval | 180 days |
| Pressure units | 39 and 1 user-defined |
Basic information precision pressure transducer
| Display | ||
|---|---|---|
| Resolution | 100 ppb or better | |
| Boot-up time | ■ RS-232 ■ RS-485 | 750 ms |
| USB | 3.5 s | |
| Warm-up time | Approx. 15 min | |
| Voltage supply | ||
| Power supply | ■ RS-232 ■ RS-485 | DC 9 ...18V (DC 12V nominal) |
| USB | DC 3.0 ...5.25V (DC 5V nominal) Bus powered | |
| Power consumption | ■ RS-232 ■ RS-485 | < 26 mAat DC 12V ±5 %(0.40W max ) |
| USB | < 47 mAat DC 5V ±5 %(0.25W max ) | |
| Internal volume | ||
| Measure port | < 1 ml [< 1 cc] | |
| Reference port | Approx. 40 ml [40 cc] |
Basic information precision pressure transducer
| Case | |
|---|---|
| Orientation effects | Removable with a zero point correction |
| Dimensions | → See technical drawings |
| Weight | Approx. 250 g [0.55 lb] (depending on range) |
| Ingress protection | IP67 |
Communication
| Interface | ■ USB 2.0 ■ RS-232 ■ RS-485 |
|---|---|
| Baud rate (User-selectable) | ■ 9600 ■ 19200 ■ 38400 ■ 57600 baud (default setting) ■ 115200 |
| Command sets | ■ Mensor default command set ■ Mensor legacy command set |
| Measuring rate | 50 values/s: default - (adjustable ex-works) |
View all (11)
Pressure connection
| Connection | ■ FSAE J514/JIC 4 ■ Autoclave ® F250C: for pressure ranges > 400 bar [> 6,000 psi] | |
|---|---|---|
| Pressure port adapters | Without | - |
| ■ 6 mmtube fitting ■ ¼" tube fitting ■ ¼NPT, male thread ■ ⅛NPT, female thread ■ ¼BSP, male thread ■ ⅛BSP, female thread ■ 7/16-20 SAE, female thread | Only up to pressure ranges 400 bar [6,000 psi] | |
| Reference port | < 100 bar [< 1,500 psi] | 1/16' barb fitting |
| ■ > 100 bar [> 1,500 psi] ■ > 100 bar abs. [> 1,500 psi abs.] | Sealed relief valve 1) | |
| Wetted parts | Pressure ranges ≤ 350 mbar [≤ 5 psi] | ■ Stainless steel 316 ■ Silicon ■ Glass-filled resins ■ Epoxy |
| Pressure ranges > 350 mbar ... 100 bar [> 5 ... 1,500 psi] | ■ Stainless steel 316 | |
| Pressure ranges > 100 bar [> 1,500 psi] | ■ Stainless steel 316 ■ Fluorocarbon rubber | |
| Overpressure limit | 2 x proof, 3 x burst, static pressure < 3.45 bar [< 50 psi] |
Operating conditions
| Altitude | < 3,048 m[< 10,000 ft] | |
|---|---|---|
| Place of use | Indoor | |
| Operating temperature | -40 ...+85 °C [-40 ...+185 °F] | |
| Compensated temperature range | 0 ... 50 °C [32 ... 122 °F] | |
| Storage temperature range | -40 ...+85 °C [-40 ...+185 °F] | |
| Relative humidity, condensation | 0 ... 95 %r.h. (non-condensing) | |
| Permissible media | Pressure ranges ≤ 350 mbar [≤ 5 psi] | Clean, dry, non-corrosive gases |
| Pressure ranges > 350 mbar [> 5 psi] | Media compatible with the listed wetted parts | |
| Mounting position | ■ Horizontal ■ Vertical ■ Customised | |
| Pollution degree | 2 per EN 61010-1 | |
| EMC (HF field) | EN 61326-1 emission (group 1, class A) and immunity (industrial application) |
| Logo | Description Region |
|---|---|
| EU declaration of conformity | European Union |
| EMCdirective 1) EN 61326-1 emission (group 1, class A) and immunity (industrial application) | |
| RoHS directive | |
| UKCA | United Kingdom |
| Electromagnetic compatibility regulations | |
| Restriction of hazardous substances (RoHS) regulations |
Certificate
| Calibration 1) | ■ A2LA calibration certificate (traceable and accredited in accordance with ISO/IEC 17025) ■ DAkkS calibration certificate - absolute pressure (traceable and accredited in accordance with ISO/IEC 17025) ■ DAkkS calibration certificate - gauge pressure (traceable and accredited in accordance with ISO/IEC 17025) |
|---|---|
| Recommended calibration interval | 6 months (dependent on conditions of use) |
| Cal-Template (demo version) | Cal-Template (light version) | Cal-Template (full version) | Log-Template (full version) |
|---|---|---|---|
| Fully automatic calibration | Semi-automatic calibration | Fully automatic calibration | ■ Live measured value recording for a certain period of time with selectable interval, duration and start time ■ Creation of logger protocols with graphic and/or tabular representation of the measuring results in PDF format ■ Possibility of exporting measuring results as CSV file |
| Limitation to two measuring points | No limitation of the measuring points approached | ||
| ■ Creation of 3.1 inspection certificates per DIN EN 10204 ■ Calibration data can be exported to Excel ® template or XML file ■ Calibration of pressure measuring instruments | |||
| Ordering information for a single licence | |||
| Is available for a cost-free download | WIKA-CAL-LZ-Z-Z | WIKA-CAL-CZ-Z-Z | WIKA-CAL-ZZ-L-Z |
| Ordering information for a pair licence | |||
| Cal-Template (light version) together with Log-Template (full version) | WIKA-CAL-LZ-L-Z | ||
| Cal-Template (full version) together with Log-Template (full version) | WIKA-CAL-CZ-L-Z |
| CPT9000 / CPT6020 1) | Order code |
|---|---|
| CPX-A-T4 | |
| Power supply Via RS-232 interface cable Cable length: 1.5 m[4.9 ft] | -1- |
| Via RS-232 interface cable Cable length: 3.0 m[9.8 ft] | -3- |
| Via RS-232 interface cable Cable length: 5.0 m[16.4 ft] | -4- |
| Power supply Via RS-485 interface cable Cable length: 1.5 m[4.9 ft] | -2- |
| Via RS-485 interface cable Cable length: 3.0 m[9.8 ft] | -J- |
| Via RS-485 interface cable Cable length: 5.0 m[16.4 ft] | -K- |
| Adapter cable RS-232 to USB | -5- |
| RS-485 to USB | -6- |
| Legacy cable adapter RS-232 cable adapter For CPT6010 to CPT9000 or CPT6020 | -8- |
| RS-485 cable adapter For CPT6010 to CPT9000 or CPT6020 | -7- |
| Pressure adapter SAE J514/JIC 4, male thread to ¼BSP, male thread P max : 400 bar [6,000 psi] | -A- |
| Pressure adapter SAE J514/JIC 4, male thread to ⅛BSP, female thread P max : 400 bar [6,000 psi] | -B- |
| Pressure adapter SAE J514/JIC 4, male thread to 6 mmtube fitting P max : 400 bar [6,000 psi] | -C- |
| Pressure adapter SAE J514/JIC 4, male thread to 7/16-20 SAE, male thread P max : 400 bar [6,000 psi] | -D- |
| Pressure adapter SAE J514/JIC 4, male thread to ¼" tube fitting P max : 400 bar [6,000 psi] | -E- |
| Pressure adapter SAE J514/JIC 4, male thread to ¼NPT, male thread P max : 400 bar [6,000 psi] | -F- |
| Pressure adapter SAE J514/JIC 4, male thread to ⅛NPT, female thread P max : 400 bar [6,000 psi] | -S- |
| Pressure adapter SAE J514/JIC 4, male thread to G½BSP, male thread P max : 400 bar [6,000 psi] | -U- |
| Gasket-flare 50 pcs. gasket-flare 37° ¼" for J514/JIC 44 pressure port | -V- |
| Accessories for CPT9000 / CPT6020 1) | Order code | |
|---|---|---|
| Description | CPX-A-T4 | |
| Communication cable Shielded with flying leads Cable length: 1.5 m[4.9 ft] Shielded with flying leads Cable length: 3.0 m[9.8 ft] Shielded with flying leads Cable length: 5.0 m[16.4 ft] | -G- | |
| -H- | ||
| -I- | ||
| - | Transport case | -T- |
| Ordering information for your enquiry: | ||
| 1. Order code: CPX-A-T4 2. Option: | ⇓ [ ] |
Industry
Machinery
High-accuracy pressure monitoring · Pressure sensing in critical applications
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →All variants · Article table
1 standard articles of family CPT
If you know the code — pick directly. If not — use the configurator in mode “01”.
Stock:
SKUConfigurationPriceStockAction