Precision digital pressure gauge
Description
The model CPG1500 precision digital pressure gauge adopts the concept of an analogue pressure gauge and at the same time works with the precision of a digital calibration instrument. The instrument thus combines the accuracy of digital measurement technology with the simplicity of an analogue measuring instrument and features impressive performance and ease of use.
The CPG1500 offers an accuracy of 0.1 % FS, 0.05 % FS or 0.025 % FS and is temperature-compensated in the range of -10 … +50 °C [14 ... 122 °F]. Measurements can be displayed in any of 26 pressure and 5 level units, or in custom units to avoid intricate conversions.
For further approvals, see page 7
Precision digital pressure gauge, model CPG1500
The measuring rate can be user-defined to match the type of measurement required. Standard applications usually use three measured values per second. If required, this measuring rate can also be set to 50 measured values per second.
Via an energy-saving function, the CPG1500 switches automatically into 'sleep' mode, in this mode the battery life can be increased up to 2,500 hours.
Through the innovative menu navigation, simple operation is ensured. The clear display, with integral bar graph display and large text area, assists with the effective analysis of the widest variety of measuring locations. With the Min./Max. function, the minimum and maximum pressures can be accessed immediately and saved automatically.
Special features
- Measuring ranges between 0 ... 10,000 bar [0 ... 150,000 psi] and also vacuum and absolute pressure measuring ranges are available
- Accuracy: up to 0.025 % (incl. calibration certificate)
- Intrinsically safe version
- Logger function with up to 50 measured values per second
- Communication with WIKA-Cal software via Bluetooth ®
Build a CPG1500 for your task
The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.
- Explosion protectionwithout
- Unitbar
- Pressure typegauge
- Measuring range0 ... 0.1 bar gauge
- Process connection—
- Version for specific medianone
- Accuracy0.2 % FS
- Type of certificate—
- Communication—
- data logger—
- protective housing capincl. protective housing cap
- Softwarewithout
- Carrying casewithout
- Certificates/Approvalswithout
- Additional accessorieswithout
- Additional ordering informationWithout
Finish your configuration
Select every option to submit the request.
| Model | CPG1500 |
| Product family | CPG |
| Subcategory | Digital pressure gauge |
| Pressure ranges | 0…10000 bar · 0…150000 psi · 0…40 bar abs. · 0…400 psi abs. · -0.25…0.25 mbar · -1…40 bar · -8…8 psi · -14.5…300 psi · 0…0.25 bar abs. · 0…0.35 psi abs. |
| Accuracy class | 0.025 % FS |
| Accuracy standard | IEC 61298-1 |
| Process connection | M20 x 1.5G ¼ BG ½ BG ⅜ BG ¼, female threadG ½ B flush with O-ring (NBR)G 1 B flush with O-ring (NBR)½ NPT¼ NPT½ NPT, female thread¼ NPT, female thread½ NPT, male threadR ½G ½, male thread on G ⅛, female threadM16 x 1.5, female thread, with sealing coneM20 x 1.5, female thread, with sealing cone9/16-18 UNF, female threadF 250-CM16 x 1.59/16-18 UNFG1/4BG1/2BG3/8BG1/4, female threadG1/2B flush with O-ring (NBR)1/2 NPT1/4 NPT1/2 NPT, female thread1/4 NPT, female thread1/2 NPT, male threadR1/2G1/2, male thread on G1/8, female thread9/16-18 UNF, female thread F250-C |
| Process temperature | −10…+50 °C |
| Output signal | Bluetooth® · Bluetooth · Bluetooth® Low Energy 4.0 · Bluetooth® Classic 2.1 |
| Power supply | 3 x 1.5 V AA batteries |
| Electrical connection | Bluetooth® |
| Case material | Aluminium die-casting, nickel-plated, Aluminium |
| Wetted parts material | Stainless steel 1.4404 (316L), Stainless steel 1.4534 (904L), Elgiloy® 2.4711, Stainless steel 1.4435 (316L), Hastelloy® 2.4819 (HC276), Gold-plated, Stainless steel, Stainless steel 1.4404 (316L), Elgiloy® 2.4711, Stainless steel 1.4435 (316L), Hastelloy® 2.4819 (HC276), Gold-plated |
| Sealing material | NBR, EPDM, G½ USIT, G¼ USIT |
| Ambient temperature | −10…+50 °C |
| IP rating | IP65 |
| Weight | 0.68 kg |
| Certifications | CERoHSREDFCCISEDICASAABNCRNEACREACHRCMNACE MR 0175 |
| Explosion protection | Ex ia IIC T4 GaEx ia IIC T4 Ga/GbEx ia IIC T4 GbII 1G Ex ia IIC T4 GaII 1/2G Ex ia IIC T4 Ga/GbII 2G Ex ia IIC T4 GbEx ia IIC T4 GcEx i Class I, Zone 0Class I, Division 1 Groups A, B, C and D T4AEx i Class I, Zone 0AEx ia IIC T4 GaEAC Ex i Zone 0 gasIntrinsically safe versionExi Class I, Zone 0 Exiia IICT4GaAExi Class I, Zone 0 AExiia IICT4GaExi Zone 0 gas ExiiaIICT4GaZone 1 connection to zone 0 gas ExiiaIICT4Ga/GbZone 1 gas ExiiaIICT4Gb |
| Datasheet languages | EN, DE, ES, FR, IT, RU, PL, NL, PT, RO, SV, EL, JA, ZH |
| Pressure types | ||
|---|---|---|
| Gauge pressure | 0 ... 10,000 bar [0 ... 150,000 psi] | |
| Absolute pressure | 0 ... 0.25 bar abs. to 0 ... 40 bar abs. [0 ... 0.35 psi abs. to 0 ... 400 psi abs.] | |
| Vacuum and +/- measuring range | -0.25 ... +0.25 mbar to -1 ... 40 bar [-8 ...+8 psi to -14.5 ... 300 psi] | |
| Accuracy 1) 2) | ■ 0.025%FS ■ 0.05%FS ■ 0.1%FS ■ 0.5%FS → Also see table 'Accuracy specifications', page 3 | |
| Connection location | Vertical mounting position, process connection lower mount | |
| Adjustment | Offset and span factor adjustable | |
| Functions | ||
| Menu functions | ■ Min./Max. alarm (visual) ■ Power-off function ■ Measuring rate ■ Mean value filter ■ Pressure rate ■ Mean value (via adjustable interval) ■ Level indication ■ Tare offset ■ Indication damping | |
| Memory | ■ Min./Max.memory ■ Integrated data logger | |
| Mean value interval | 1 ... 300 seconds, adjustable | |
| Measuring rate | Max. 50/s | |
| Data logger 3) | ■ Cyclic logger ⇒ Automatic recording of up to 1,000,000 values ■ Cycle time ⇒ Selectable from 1 ... 3,600 s in 1-second steps ⇒ Selectable with the measuring rate in the following steps: 1/s, 3/s, 10/s and 50/s | |
| Battery status display | Symbol display with 4 bars indicates the battery status in 25 %steps. | |
| Case | ||
| Rotatability | The case is rotatable by 330°. | |
| Dimensions | → See dimensions in mm[in], page 10 | |
| Ingress protection | IP65 | |
| Weight | Incl. batteries | Approx. 680 g [1.5 lbs] |
| Display | |||
|---|---|---|---|
| Display range | -199999 ... 199999 digits 5 ½-digit 7-segment display (incl. a large matrix area for auxiliary information) | ||
| Display resolution | 4 ... 5 ½digits; adjustable; depending on the selected pressure unit | ||
| Backlighting | Adjustable via key | ||
| Bar graph | 0 …100 %, 20 individual segments, which show 5 %steps | ||
| Menu languages | Adjustable via menu | ||
| ■ English ■ German ■ Spanish ■ French | ■ Italian ■ Russian ■ Polish | ||
| Pressure units | Adjustable via menu | ||
| ■ mbar ■ bar ■ psi ■ Pa ■ hPa ■ kPa ■ MPa | ■ atm ■ Torr ■ mmHg ■ cmHg ■ inHg ■ inHg (0 °C) ■ inHg (60 °F) | ■ mmH₂O ■ mH₂O ■ inH₂O ■ inH₂O (4 °C) ■ inH₂O (20 °C) ■ inH₂O (60 °F) ■ ftH₂O ■ kg/cm² ■ kp/cm� ■ lbf/ft² ■ kN/m² ■ micron |
| Accuracy 1) 2) | ||
|---|---|---|
| Gauge pressure | ■ 0.025%FS 3) 4) ■ 0.05%FS 3) | 1 ... 1,000 bar [15 ... 15,000 psi] |
| 0.1%FS | 1 ... 2,500 bar [15 ... 50,000 psi] | |
| 0.5%FS | 4,000 ... 10,000 bar [60,000 ... 150,000 psi] | |
| Absolute pressure | ■ 0.025%FS 3) 4) ■ 0.05%FS 3) ■ 0.1%FS | 1 ... 40 bar abs. [15 ... 500 psi abs.] |
| Vacuum and +/- measuring range | ■ 0.025%FS 3) 4) ■ 0.05%FS 3) ■ 0.1%FS | -1 ... 0 bar to -1 ... 40 bar and -0.6 ... +0.6 bar [-14.5 ... 0 psi to -14.5 ... 300 psi, and -8 ...+8 psi] |
| Compensated range | -10 ... 50 °C [14 ... 122 °F] | |
| Reference conditions per IEC 61298-1 5) | ||
| Ambient temperature | 15 ... 25 °C [59 ... 77 °F] | |
| Atmospheric pressure | 860 ... 1,060 mbar [12.5 ... 15.4 psig] | |
| Humidity | < 95 %r.h. (non-condensing) | |
| Mounting position | Vertical mounting position, process connection facing downwards | |
| Calibration | Calibrated at 23 °C [74 °F] and in a vertical mounting position, process connection facing downwards |
| bar | |
|---|---|
| 0 ... 0.1 | 0 ... 200 |
| 0 ... 0.25 | 0 ... 250 |
| 0 ... 0.4 | 0 ... 400 |
| 0 ... 0.6 | 0 ... 600 |
| 0 ... 1 | 0 ... 700 1) |
| 0 ... 1.6 | 0 ... 1,000 1) |
| 0 ... 2.5 | 0 ... 1,600 1) |
| 0 ... 4 | 0 ... 2,500 1) |
| 0 ... 6 | 0 ... 4,000 1) |
| 0 ... 10 | 0 ... 5,000 1) |
| 0 ... 16 | 0 ... 6,000 1) |
| 0 ... 25 | 0 ... 7,000 1) 2) |
| 0 ... 40 | 0 ... 8,000 1) 2) |
| 0 ... 60 | 0 ... 9,000 1) 2) |
| 0 ... 100 | 0 ... 10,000 1) 2) |
| 0 ... 160 | - |
View all (20)
| 0 ... 0.25 | 0 ... 6 |
|---|---|
| 0 ... 0.4 | 0 ... 7 |
| 0 ... 0.6 | 0 ... 10 |
| 0 ... 1 | 0 ... 16 |
| 0 ... 1.6 | 0 ... 20 |
| 0 ... 2.5 | 0 ... 25 |
| 0 ... 4 | 0 ... 40 |
| bar | |
|---|---|
| -0.25 ... +0.25 | -1 ... 7 |
| -0.4 ... +0.4 | -1 ... 9 |
| -0.6 ... +0.6 | -1 ... 10 |
| -1 ... 0 | -1 ... 15 |
| -1 ... +0.6 | -1 ... 24 |
| -1 ... 1.5 | -1 ... 25 |
| -1 ... 2.5 | -1 ... 39 |
| -1 ... 3 | -1 ... 40 |
| -1 ... 5 | - |
| psi | |
|---|---|
| 0 ... 5 | 0 ... 2,000 |
| 0 ... 10 | 0 ... 3,000 |
| 0 ... 15 | 0 ... 5,000 |
| 0 ... 20 | 0 ... 6,000 |
| 0 ... 30 | 0 ... 8,000 |
| 0 ... 50 | 0 ... 10,000 1) |
| 0 ... 60 | 0 ... 15,000 1) |
| 0 ... 100 | 0 ... 20,000 1) |
| 0 ... 150 | 0 ... 30,000 1) |
| 0 ... 160 | 0 ... 40,000 1) |
| 0 ... 200 | 0 ... 50,000 1) |
| 0 ... 300 | 0 ... 60,000 1) |
| 0 ... 500 | 0 ... 75,000 1) |
| 0 ... 700 | 0 ... 100,000 1) 2) |
| 0 ... 1,000 | 0 ... 150,000 1) 2) |
| 0 ... 1,500 | - |
| 0 ... 3.5 | 0 ... 60 |
|---|---|
| 0 ... 5 | 0 ... 100 |
| 0 ... 10 | 0 ... 150 |
| 0 ... 15 | 0 ... 200 |
| 0 ... 20 | 0 ... 300 |
| 0 ... 30 | 0 ... 500 |
| 0 ... 50 | - |
| psi | |
|---|---|
| -14.5 ... 0 | -8 ...+8 |
| -14.5 ...+15 | -5 ...+5 |
| -14.5 ... 40 | -3 ...+3 |
| -14.5 ... 70 | -8 ... 0 |
| -14.5 ... 100 | -5 ... 0 |
| -14.5 ... 130 | -3 ... 0 |
| -14.5 ... 300 | - |
| Overpressure limit | ||
|---|---|---|
| 3 times | < 25 bar | < 360 psi |
| 2 times | > 25 ...≤ 600 bar | > 360 ...≤ 8,700 psi |
| 1.5 times | > 600 ...≤ 1,600 bar | > 8,700 ...≤ 25,000 psi |
| 1.3 times | > 1,600 ...≤ 6,000 bar | > 25,000 ...≤ 85,000 psi |
| 1.1 times | > 6,000 bar | > 85,000 psi |
| Display | > 110 %FSor -10%FS | |
| Vacuum resistance | Yes |
| Standard | Thread sizes | Possible measuring ranges |
|---|---|---|
| EN 837 | ■ G¼B ■ G½B ■ G⅜B ■ G¼, female thread | ≤ 1,000 bar [≤ 15,000 psi] |
| G½Bflush with O-ring (NBR) | 2.5 ... 600 bar [50 ... 6,000 psi] | |
| G1Bflush with O-ring (NBR) | 0.4 ... 16 bar [10 ... 200 psi] | |
| ANSI/ASME B1.20.1 | ■ ½NPT ■ ¼NPT ■ ½NPT, female thread ■ ¼NPT, female thread ■ ½NPT, male thread | ≤ 1,000 bar [≤ 15,000 psi] |
| DIN 16288 | M20 x 1.5 | ≤ 1,000 bar [≤ 15,000 psi] |
| ISO 7 (DIN 2999) | R½ | ≤ 1,000 bar [≤ 15,000 psi] |
| DIN EN ISO 1179-2 | G½, male thread on G⅛, female thread | ≤ 400 bar [≤ 5,800 psi] |
| - | M16 x 1.5, female thread, with sealing cone | ≥ 100 bar [≥ 1,500 psi] |
| M20 x 1.5, female thread, with sealing cone | 1,600 ... 10.000 bar [30,000 ... 150,000 psi] | |
| 9/16-18 UNF, female thread F 250-C | 100 ... 7,000 bar [1,500 ... 100,000 psi] |
| Process connection adapter 1) | ■ Without ■ G½to¼NPT ■ G½to½NPT | |
|---|---|---|
| Sealing | ■ NBR ■ EPDM | |
| Other versions | ||
| Oil- and grease-free | Per G93:2019 level D (< 220 mg/m²) | |
| Oxygen, oil- and grease-free | ■ Per G93:2019 level D (< 220 mg/m²) ■ Particle < 1,000 μm | |
| Material | ||
| Case | Aluminium die-casting, nickel-plated | |
| Wetted parts | -1 ...< 40 bar [-14.5 ...< 500 psi] | Stainless steel 1.4404 (316L) |
| > 40 bar ...≤ 1,000 bar [> 500 ...≤ 15,000 psi] | ■ Process connection: Stainless steel 1.4404 (316L) ■ Sensor: Elgiloy ® 2.4711 | |
| > 1,000 bar [>15,000 psi] | Stainless steel 1.4534 (904L) | |
| -1 ... 10,000 bar [-14,5 ... 150,000 psi] | ■ Stainless steel 1.4435 (316L) ■ Hastelloy ® 2.4819 (HC276) ■ Gold-plated |
| Internal pressure transmission medium | Synthetic oil | With measuring ranges up to ≤ 25 bar [≤ 360 psi] |
|---|---|---|
| Halocarbon oil | For oxygen version |
| Bluetooth ® 1) | ||
|---|---|---|
| Version | Bluetooth ® Low Energy 4.0 | |
| Bluetooth ® Classic 2.1 | ||
| Frequency range | 2,400 ... 2,500 MHz | |
| HF output power | Max. 2 dBm (+ 2 dBi) | |
| Number of channels | Classic | 79 |
| Low Energy | 40 | |
| Channel spacing | Classic | 1 MHz |
| Low Energy | 2 MHz | |
| Bandwidth | 1 or 2 MHz | |
| Max. transmission power | max. 4 dBm / 2.51mW |
| Battery | 3 x 1.5V AA batteries 1) |
|---|---|
| Battery voltage | DC 4.95V |
| Battery life | Typically 2,000 …2,500 h (without backlighting and with Bluetooth ® not active) |
| Medium temperature range | -10 ...+50 °C [14 ... 122 °F] Lower temperature limit above the freezing point of the medium |
|---|---|
| Operating temperature | -10 ...+50 °C [14 ... 122 °F] |
| Storage temperature range | -20 ...+70 °C [-4 ...+158 °F] |
| Relative humidity, condensation | < 95 %r.h. (non-condensing) |
| Permissible media | All liquids and gases which are compatible with 316 stainless steel |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity EMCdirective | European Union | |
| Radio Law Japan Radio approval | Japan | |
| Federal Communications Commission (FCC) for US Radio approval | USA | |
| - | Innovation, Science and Economic Development (ISED) for Canada Radio approval | Canada |
| - | ICASA Radio certification | South Africa |
| Radiocommunications Equipment Rules Radio approval Australia - ABN 49 004 465 936 New Zealand - Company number 400909 | Australia and New | |
| Zealand |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity | European Union | |
| ATEX directive Hazardous areas | ||
| Ex i Zone 0 gas Zone 1 Zone 1 gas | II 1G Ex ia IIC T4 Ga connection to zone 0 gas II 1/2G Ex ia IIC T4 Ga/Gb II 2G Ex ia IIC T4 Gb T4 at -10 …+50 °C | |
| IECEx Hazardous areas | International | |
| Ex i Zone 0 gas | Ex ia IIC T4 Ga | |
| Zone 1 gas | Ex ia IIC T4 Gb | |
| Zone 2 | Ex ia IIC T4 Gc | |
| gas |
| Logo | Description | Region | |
|---|---|---|---|
| CSA (only up to 6,000 bar [85,000 psi]) | USA and Canada | ||
| Safety (e.g. electr. safety, overpressure, ...) Class - 3631 06 - Electrical measurement and inspection equipment Class - 3631 86 - Electrical equipment for measurement - certified according to US standards | |||
| Hazardous areas Class - 2258 04 - PROCESS CONTROL EQUIPMENT - Intrinsically-safe, Entity - hazardous area | |||
| Ex i Class Class | Ex ia IIC T4 Ga Groups A, B, C and DT4 T4 at -10 …+50 °C | ||
| Hazardous areas Class - 2258 84 - PROCESS CONTROL EQUIPMENT - Intrinsically-safe, Entity - hazardous area - certified in accordance with US standards | |||
| AEx i Class Class | AEx ia IIC T4 Ga Groups A, B, C and DT4 T4 at -10 …+50 °C | ||
| EAC EMCdirective | Eurasian Economic Community | ||
| Hazardous areas | |||
| - | MChS Permission for commissioning | Kazakhstan | |
| - | PAC Ukraine Metrology, measurement technology | Ukraine | |
| - | CRN Safety (e.g. electr. safety, overpressure, ...) | Canada |
| Certificates | ■ Without ■ 2.2 test report with NACE MR0175 approval 2) ■ 2.2 test report with confirmation of manufactured according to state-of-the-art technology ■ 3.1 inspection certificate with wetted parts approvals incl. chemical analysis ■ 2.2 test report with NACE MR0175 approval together with 3.1 inspection certificate with wetted parts approvals incl. chemical analysis 2) |
|---|---|
| Calibration 1) | ■ 3.1 inspection certificate per DIN EN 10204 ■ DAkkS calibration certificate (traceable and accredited in accordance with ISO/IEC 17025) |
| Recommended calibration interval | 1 year (dependent on conditions of use) |
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →20 standard articles of family CPG
If you know the code — pick directly. If not — use the configurator in mode “01”.