AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
CPC8000 1
CPC8000
On order
WIKA · Calibration technology · Family CPC

Pressure controller

High-end pressure controller with premium accuracy, suitable as a factory or working standard for calibration of pressure measuring instruments, featuring patented valve technology and modular transducer design.
Range
-1…401 bar
Protection
None
RoHSCEUKCA
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Special features

  • Pressure ranges: -1 ... 400 bar [-15 ... 6,000 psi]
  • Control stability 0.002 % of the span
  • Accuracy down to 0.008 % IS (IntelliScale)
  • Precision 0.004 % FS
Identification
ModelCPC8000
Product familyCPC
SubcategoryPressure controller
Measuring range
Pressure ranges-1…400 bar · 0…400 bar · 0…0.35 bar · 0…0.5 bar · 0…401 bar · 0…100 bar · -1…1 bar
Temperature ranges+15…+45 °C · +0…+70 °C
Accuracy
Uncertainty0.008 % of reading (IS)
Process conditions
Mediumdry, clean air, nitrogen
Calibration typedeadweight
Operating environment
Ambient temperature+15…+40 °C
Weight22.2 kg
Certifications and approvals
Certifications
RoHSCEUKCA
TraceabilityA2LA · DAkkS
Additional details
PortableNo
Datasheet languagesEN, DE, IT, FR, NL, PL, PT, RO, ES, SV, RU, EL, JA, ZH
Tables from datasheet
Reference pressure transducer model CPR8000
Pressure range
Accuracy 1)0.008%FS 2)0.008 %IS-50 3)0.008 %IS-33 4)
Gauge pressure 5)0 ... 0.35 up to 0 ... 400 bar [0 ... 5 up to 0 ... 6,000 psi]0 ... 1 up to 0 ... 400 bar [0 ... 15 up to 0 ... 6,000 psi]0 ... 1 up to 0 ... 100 bar [0 ... 15 up to 0 ... 1,500 psi]
Bidirectional-1 ...+1 up to -1 ... 400 bar [-15 ...+15 up to -15 ... 6,000 psi]-1 ... 10 up to -1 ... 400 bar [-15 ... 145 up to -15 ... 6,000 psi]-1 ... 10 up to -1 ... 100 bar [-15 ... 145 up to -15 ... 1,500 psi]
Absolute pressure 6)0 ... 0.5 up to 0 ... 401 bar abs. [0 ... 7.5 up to 0 ... 6,015 psi abs.]0 ... 1 up to 0 ... 401 bar abs. [0 ... 15 up to 0 ... 6,015 psi abs.]0 ... 1 up to 0 ... 101 bar abs. [0 ... 15 up to 0 ... 1,515 psi abs.]
Precision 7)0.004%FS
Calibration interval365 days 8)365 days365 days
Barometric reference
Measuring range■ 552 ... 1.172 mbar abs. ■ 8 ... 17 psi abs. ■ 552 ... 1.172 hPa abs.
Accuracy 2)0.01 %of reading
FunctionThe barometric reference can be used to switch pressure types 2) , absolute <=> gauge. With gauge pressure transducers, the measuring range of the transducers must begin with -1 bar [-15 psi] in order to carry out an absolute pressure emulation.
Communication
Interface■ Ethernet ■ IEEE-488 ■ USB ■ RS-232
Baud rate■ 9600 ■ 19200 ■ 38400 ■ 57600 ■ 115200
Command sets■ Mensor ■ WIKA SCPI ■ Others on request
Response time< 100 ms
Digital I/O Digital inputDC 3.3V or DC 5 V; current limited by 330 Ωresistor
Digital output0.5 A at AC 125V
Voltage supply
Operating voltage■ AC 100 ... 120 V, 50/60 Hz ■ AC 220 ... 240 V, 50/60 Hz
Power consumptionMax.130VA
Supply voltage fluctuation±10%
Fuse1.6 A, 250V;SLO-BLO5x20mm
View all (12)
Operating conditions
Place of useIndoor Not for wet locations
AltitudeUp to 3,048 m[10,000 ft] above sea level
Operating temperature15 ... 40 °C [59 ... 104 °F]
Compensated temperature range15 ... 45 °C [59 ... 113 °F]
Storage temperature0 ... 70 °C [32 ... 158 °F]
Relative humidity, condensation0 ... 95 %r.h. (non-condensing)
Mounting position of transducersHorizontal or slightly tilted
Permissible pollution degreeDegree 2
EMC (HF field)EN 61326-1 emission (group 1, class A) and immunity (industrial application)
LogoDescriptionRegion
EU declaration of conformityEuropean Union
EMCdirective 1) EN 61326 emission (group 1, class A) and immunity (industrial application)
LowVoltage Directive
RoHS directive
UKCAUnited Kingdom
Electromagnetic compatibility regulations
Electrical equipment designed for use within certain voltage limits in support of the electrical equipment (safety) regulations
Restriction of hazardous substances (RoHS) regulations
LogoDescriptionRegion
-MChS Permission for commissioningKazakhstan
-PAC China Metrology, measurement technologyChina
LogoDescription
-China RoHS directive
Certificates
Calibration 1)
Barometric reference■ Without ■ A2LA calibration certificate (traceable and accredited in accordance with ISO/IEC 17025) ■ DAkkS calibration certificate for barometric reference (traceable and accredited in accordance with ISO/IEC 17025)
Reference pressure transducer model CPR8000■ A2LA calibration certificate (traceable and accredited in accordance with ISO/IEC 17025) ■ DAkkS calibration certificate - gauge pressure (traceable and accredited in accordance with ISO/IEC 17025) ■ DAkkS calibration certificate - absolute pressure (traceable and accredited in accordance with ISO/IEC 17025)
Recommended calibration interval1 year (dependent on conditions of use)
Cal-Template (demo version)Cal-Template (light version)Cal-Template (full version)Log-Template (full version)
Fully automatic calibrationSemi-automatic calibrationFully automatic calibration■ Live measured value recording for a certain period of time with selectable interval, duration and start time ■ Creation of logger protocols with graphic and/or tabular representation of the measuring results in PDF format ■ Possibility of exporting measuring results as CSV file
Limitation to two measuring pointsNo limitation of the measuring points approached
■ Creation of 3.1 inspection certificates per DIN EN 10204 ■ Calibration data can be exported to Excel ® template or XML file ■ Calibration of pressure measuring instruments
Ordering information for a single licence
Is available for a cost-free downloadWIKA-CAL-LZ-Z-ZWIKA-CAL-CZ-Z-ZWIKA-CAL-ZZ-L-Z
Ordering information for a pair licence
Cal-Template (light version) together with Log-Template (full version)WIKA-CAL-LZ-L-Z
Cal-Template (full version) together with Log-Template (full version)WIKA-CAL-CZ-L-Z
Description 1)Order code
CPX-A-C8
-Desktop case-D-
-19" rack mount case With side pieces, EU With side pieces,NAM-R- -U-
Barometric reference Measuring range: 8 ... 17 psi abs. Accuracy to 0.01 %of reading-3-
Measuring range: 552 ... 1,172 mbar abs. Accuracy to 0.01 %of reading-K-
Measuring range: 552 ... 1,172 hPa abs. Accuracy to 0.01 %of reading-L-
Calibration adapter For reference pressure transducers, voltage supply and software-4-
Calibration adapter For barometric reference, voltage supply and software-5-
Transport case-6-
Silencer-7-
RS-232 interface cable-9-
-Vacuum pump-2-
Adapter set 6 mmSwagelok ® male thread (4 adapters) Max. 137 bar [2,000 psi] Material: brass-M-
Adapter set 6 mmSwagelok ® male thread (4 adapters) Max. 400 bar [6,000 psi] Material: stainless steel-C-
Adapter set ¼" tube fitting (4 adapters) Max. 137 bar [2,000 psi] Material: brass-I-
Adapter set ¼" tube fitting (4 adapters) Max. 400 bar [6,000 psi] Material: stainless steel-E-
Description 1)Order code
CPX-A-C8
Adapter set ⅛BSPG, female thread (4 adapters) Max. 137 bar [2,000 psi] Material: brass-B-
Adapter set ¼NPT, female thread (4 adapters) Max. 137 bar [2,000 psi] Material: brass-N-
Adapter set ¼NPT, female thread (4 adapters) Max. 400 bar [6,000 psi] Material: stainless steel-A-
Adapter set ⅛NPT, female thread (4 adapters) Max. 137 bar [2,000 psi] Material: brass-S-
Adapter set ⅛NPT, female thread (4 adapters) Max. 400 bar [6,000 psi] Material: stainless steel-F-
Ordering information for your enquiry:
1. Order code: CPX-A-C8 2. Option:⇓ [ ]