Standard reference resistor
Description
This model is available in two series: CER6000-RR (reference resistor) and CER6000-RW (standard reference resistor). The RR series of 4-wire reference resistors offer high accuracy and stability at an economic cost. Designed specifically for use as a comparison standard for AC thermometry resistance bridges of the ASL range, the RR series may also be used in electrical standards laboratories.
In addition to standard fixed values, resistors can be supplied in any value between 1 and 10,000 Ω. Typical applications for the RR series are as transfer standards or reference source in temperature calibration or electrical standards laboratories.
Standard reference resistor, model CER6000, 25 Ω and 100 Ω
The RW series is made from a specially selected alloy having a low temperature coefficient mounted in a strain-free manner on formers made from a material of low dielectric loss but of high mechanical stability.
Prolonged heat treatment of the elements ensures long-term stability and low temperature coefficient of resistance. The elements are hermetically sealed in stainless steel containers and filled with dry oil Castrol WOM 14.
Special features
- High accuracy
- Excellent long-term stability
- Low temperature coefficient
- Rugged stainless steel construction
| Model | CER6000 |
| Subcategory | Reference resistor |
| Temperature ranges | +15…+40 °C |
| Uncertainty | ±10 ppm |
| Calibration type | electronic |
| Ambient temperature | +15…+40 °C |
| IP rating | IP65 |
| Weight | 0.5 kg |
| Traceability | DAkkS · UKAS · NPL |
| Portable | Yes |
| Datasheet languages | EN |
| Resistance value | 1, 10, 25, 100, 300, 400, 500, 1,000 and 10,000Ω Others on request |
|---|---|
| Tolerance | ±10 ppm |
| Long-term stability | < ±5 ppm per year |
| Temperature coefficient | Typically < 1 ppm per °C |
| Frequency dependence | < 1 ppm up to 400 Hz |
| Permissible ambient conditions | |
| Working temperature | 20 °C [68 °F] |
| Operating temperature | 15 ... 40 °C [59 ... 104 °F] |
| Case | |
| Dimensions | Ø=76mm, height 114 mm[Ø=2.99 in, height 4.49 in] |
| Weight | 0.5 kg [1.1 lbs] |
| Resistance value | 1, 10, 25, 100, 300, 400, 500, 1,000 and 10,000Ω Others on request |
|---|---|
| Tolerance | ±10 ppm |
| Long-term stability | < 1 kΩ; 2 ppm per year (HS version 0.5 ppm per year) |
| ≥ 1 kΩ; 5 ppm per year | |
| Temperature coefficient | Typically 2 ppm per °C (HS version 0.5 ppm per °C) |
| Frequency dependence | 1 ppm up to 1,592 Hz |
| Permissible ambient conditions | |
| Working temperature | 20 °C [68 °F] |
| Operating temperature | 15 ... 40 °C [59 ... 104 °F] |
| Case | |
| Dimensions | Ø=76mm, height 114 mm[Ø=2.99 in, height 4.49 in] |
| Weight | 0.7 kg [1.5 lbs] |
| Calibration | ■ Without ■ DAkkS/UKAS calibration certificate - DC at 20 °C [68 °F] ■ DAkkS calibration certificate - DC at 23 °C [73 °F] ■ DAkkS/UKAS calibration certificate - DC and AC at 20 °C [68 °F] ■ DAkkS calibration certificate - DC and AC at 23 °C [73 °F] ■ NPL calibration certificate - DC at 20 °C [68 °F] or 23 °C [73 °F] ■ NPL calibration certificate - DC and AC at 20 °C [68 °F] or 23 °C [73 °F] |
|---|---|
| Recommended recalibration interval | 1 year (dependent on conditions of use) |
Couldn't find the answer in the documentation? An engineer will reply within a business day.