AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
A-1200 1
A-1200
On order
WIKA · Pressure measurement · Family A-1200

Pressure sensor with IO-Link

Pressure sensor with IO-Link and PNP/NPN switching output for industrial applications, featuring robust design and digital connectivity.
Range
-1…1000 bar
Output
PNP · NPN
Accuracy
≤ ±1 % of span
Protection
IP65/IP67
CERoHSEACUL
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The model A-1200 is a pressure sensor without display that can be flexibly programmed via IO-Link and used in a variety of ways - whether for pressure monitoring or as an electronic PNP/NPN switch for process control.

Special features

  • Industry 4.0-ready IO-Link sensor improves connectivity and diagnostics
  • Designed for rough demands of up to 1,000 g shock and -40 ... +125 °C [-40 ... +257 °F]
  • Optimised design makes OEM machine integration easier
  • Multicolour 360° LED status display simplifies troubleshooting and localisation
Identification
ModelA-1200
SubcategoryPressure sensor
Measuring range
Pressure ranges0…0.4 bar · 0…0.6 bar · 0…1 bar · 0…1.6 bar · 0…2.5 bar · 0…4 bar · 0…6 bar · 0…10 bar · 0…16 bar · 0…25 bar · 0…40 bar · 0…60 bar · 0…100 bar · 0…160 bar · 0…250 bar · 0…400 bar · 0…600 bar · 0…1000 bar · 0…10 psi · 0…15 psi · 0…25 psi · 0…30 psi · 0…50 psi · 0…100 psi · 0…160 psi · 0…200 psi · 0…300 psi · 0…500 psi · 0…1000 psi · 0…1500 psi · 0…2000 psi · 0…3000 psi · 0…5000 psi · 0…7500 psi · 0…10000 psi · 0…15000 psi · -1…0 bar · -1…0.6 bar · -1…1.5 bar · -1…3 bar · -1…5 bar · -1…9 bar · -1…15 bar · -1…24 bar · -14.5…0 psi · -14.5…15 psi · -14.5…30 psi · -14.5…50 psi · -14.5…100 psi · -14.5…160 psi · -14.5…200 psi · -14.5…300 psi
Accuracy
Accuracy class≤ ±1 % of span
Accuracy standardIEC 61298-1
Process conditions
Process connection
G¼AG½AG¼BG¼femaleG½B¼NPT½NPTR ¼PT ¼G¼female (Ermeto compatible)
Process temperature−40…+125 °C
Electrical characteristics
Output signalPNP · NPN · IO-Link
Power supply10...32 V DC
Electrical connectionM12 x 1 circular connector (4-pin), DIN 175301-803 A (3-pin)
Switching functionNormally open, normally closed, window, hysteresis
Switching contacts2
Materials
Case material316L
Wetted parts material316L, PH grade steel
Sealing materialNBR, FPM/FKM, Copper, stainless steel
Operating environment
Ambient temperature−40…+85 °C
IP ratingIP65/IP67
Certifications and approvals
Certifications
CERoHSEACUL
Additional details
Datasheet languagesEN
Tables from datasheet
Gauge pressure
bar0 ... 0.40 ... 0.60 ... 10 ... 1.60 ... 2.50 ... 40 ... 60 ... 10
0 ... 160 ... 250 ... 400 ... 600 ... 1000 ... 1600 ... 2500 ... 400
0 ... 6000 ... 1,000
psi0 ... 100 ... 150 ... 250 ... 300 ... 500 ... 1000 ... 1600 ... 200
0 ... 3000 ... 5000 ... 1,0000 ... 1,5000 ... 2,0000 ... 3,0000 ... 5,0000 ... 7,500
0 ... 10,0000 ... 15,000
Absolute pressure
bar0 ... 0.40 ... 0.60 ... 10 ... 1.60 ... 2.50 ... 40 ... 60 ... 10
0 ... 160 ... 25
psi0 ... 100 ... 150 ... 250 ... 300 ... 500 ... 1000 ... 1600 ... 200
0 ... 300
Vacuum and +/- measuring range
bar-1 ... 0-1 ... +0.6-1 ... +1.5-1 ...+3-1 ...+5-1 ...+9-1 ...+15-1 ...+24
psi-14.5 ... 0-14.5 ...+15-14.5 ...+30-14.5 ...+50-14.5 ...+100-14.5 ...+160-14.5 ...+200-14.5 ...+300
Switching outputIO-Link 1.1Teach
SP1SP2
PNP---
PNP-x-
NPN---
PNP--x
NPN--x
PNPPNPx-
NPNNPN--
StandardOption 1) 2)
Medium-30 ...+100 °C [-22 ...+212 °F]-40 ...+125 °C [-40 ...+257 °F)
Ambient-30 ...+85 °C [-22 ...+185 °F]-40 ...+85 °C [-40 ...+185 °F]
Storage-40 ...+70 °C [-40 ...+158 °F]
Nominal temper - ature-20 ...+80 °C [-4 ...+176 °F]
StandardThreadMax. nominal pressureSealing
DIN EN ISO 1179-2 (formerly DIN 3852-E)G¼A600 bar [8,700 psi]NBR (options: Without, FPM/FKM)
G½A400 bar [5,800 psi]NBR (options: Without, FPM/FKM)
EN 837G¼B 1)1,000 bar (14,500 psi)without (options: Copper, stainless steel)
G¼female 1)1,000 bar (14,500 psi)without (options: Copper, stainless steel)
G½B 1)1,000 bar (14,500 psi)without (options: Copper, stainless steel)
ANSI/ASME B1.20.1¼NPT1)1,000 bar (14,500 psi)-
½NPT1)1,000 bar (14,500 psi)-
ISO 7R ¼1)1,000 bar (14,500 psi)-
KSPT ¼1)1,000 bar (14,500 psi)-
-G¼female (Ermeto compatible)1,000 bar (14,500 psi)without (options: Copper, stainless steel)
View all (12)
ConnectionIngress protection (per IEC 60529)
Circular connector M12 x 1, metal (4-pin)IP65 and IP67
Circular connector M12 x 1 (4-pin)
with LED status displayIP65 and IP67
without LED status displayIP65 and IP67
Angular connector DIN 175301-803 A (3-pin) 1)
with LED status displayIP65
without LED status displayIP65
GL1
G¼B13 [0.51]
G½B20 [0.79]
GL1
¼NPT13 [0.51]
½NPT19 [0.75]
R¼13 [0.51]
PT¼13 [0.51]
Sealings
DescriptionOrder number
NBR profile sealing G¼ADINENISO1179-2 (formerly DIN 3852-E)1537857
FPM/FKM profile sealing G¼ADINENISO1179-2 (formerly DIN 3852-E)1576534
NBR profile sealing G½ADINENISO1179-2 (formerly DIN 3852-E)1039067
FPM/FKM profile sealing G½ADINENISO1179-2 (formerly DIN 3852-E)1039075
CopperG¼BEN83711250810
Stainless steelG¼BEN83711250844
CopperG½BEN83711250861
Stainless steelG½BEN83711251042
DescriptionTemperature rangeCable diameterOrder number
Straight version, cut to length, 4-pin,2m [6.6 ft] PUR cable, UL listed, IP67-20 ...+80 °C [-4 ...+176 °F]4.5mm [0.18 in]14086880
Straight version, cut to length, 4-pin,5m [16.4 ft] PUR cable, UL listed, IP67-20 ...+80 °C [-4 ...+176 °F]4.5mm [0.18 in]14086883
Straight version, cut to length, 4-pin, 10m [32.8 ft] PUR cable, UL listed, IP67-20 ...+80 °C [-4 ...+176 °F]4.5mm [0.18 in]14086884
Angled version, cut to length, 4-pin,2m [6.6 ft] PUR cable, UL listed, IP67-20 ...+80 °C [-4 ...+176 °F]4.5mm [0.18 in]14086889
Angled version, cut to length, 4-pin,5m [16.4 ft] PUR cable, UL listed, IP67-20 ...+80 °C [-4 ...+176 °F]4.5mm [0.18 in]14086891
Angled version, cut to length, 4-pin, 10m [32.8 ft] PUR cable, UL listed, IP67-20 ...+80 °C [-4 ...+176 °F]4.5mm [0.18 in]14086892
Connection cable, 4-pin, 2 m[6.6 ft] PUR cable, UL listed, IP67 1x LED green, 2x LED yellow-20 ...+80 °C [-4 ...+176 °F]4.5mm [0.18 in]14252834
Connection cable, 4-pin, 5 m[16.4 ft] PUR cable, UL listed, IP67 1x LED green, 2x LED yellow-20 ...+80 °C [-4 ...+176 °F]4.5mm [0.18 in]14252835
DescriptionOrder number
IO-Link master ■ USB port for setting, monitoring and diagnosing IO-Link instruments on notebook or desktop PC. ■ Connection of the IO-Link instruments via M12 x 1 circular connector ■ Licence for PC software (system requirement:Windows 7 / 8.1 and Windows 10 (32 or 64 bit) ■ Suitable for IO-Link version V1.0 and V1.1 ■ 115/230V AC - 24V DC (1 A) external power supply and international adapter included ■ Instruments with a current requirement of up to 80 mAcan be operated without external pow - er, otherwise, the DC 24V (1 A) external power supply must be connected.14239506
LogoDescriptionCountry
EU declaration of conformity ■ EMCdirective, EN 61326 emission (group 1, class B) and immunity (industrial application) ■ Pressure equipment directive ■ RoHS directiveEuropean Union
UL Safety (e.g. electr. safety, overpressure, ...)USA and Canada
EAC EMCdirectiveEurasian Economic Community
GOST Metrology, measurement technologyRussia
LogoDescription
-China RoHS directive
-MTTF > 100 years