WIKA · Pressure measurement · Family A2G
Differential pressure switch
For ventilation and air-conditioning
Range
20…4500 Pa
Accuracy
±8 Pa
Protection
IP54
RoHSEACWEEECEEMC
Price
On request
Depends on configuration
Description
The model A2G-40 differential pressure switch, in the Δp function, monitors filters and ventilators in ventilation ducts and air shutters.
Six pressure range increments are available. The differential pressure switch is characterised by its simple mounting and high reliability.
Differential pressure switch, model A2G-40
Special features
- Six pressure range increments
- Easy to install and assemble
- Very reliable
- Robust case and practical design
Identification
| Model | A2G-40 |
| Product family | A2G |
| Subcategory | Differential pressure switch |
Measuring range
| Pressure ranges | 20…200 Pa · 30…300 Pa · 30…500 Pa · 40…600 Pa · 100…1500 Pa · 500…4500 Pa |
Accuracy
| Accuracy class | ±8 Pa, ±20 Pa, ±100 Pa |
Process conditions
| Process connection | Connecting nozzle, side mount, for hoses with inner diameter 4 ... 6 mm |
| Process temperature | −20…+60 °C |
Electrical characteristics
| Electrical connection | Cable gland M16, Screw terminals max. 1.5 mm² |
| Switching function | Switch point with fixed differential |
| Switching contacts | 1 |
Materials
| Case material | Plastic (ABS) |
| Wetted parts material | Silicone, Plastic, Diaphragm: Silicone, Seals: Plastic |
| Sealing material | Plastic |
Operating environment
| Ambient temperature | −20…+85 °C |
| IP rating | IP54 |
| Weight | 0.15 kg |
Certifications and approvals
| Certifications | RoHSEACWEEECEEMC |
Additional details
| Datasheet languages | EN |
Tables from datasheet
Differential pressure switch, model A2G-40
| Switch point accuracy | Pressure range | Lowest limit | Highest limit | Switch differential |
|---|---|---|---|---|
| 20 ... 200 Pa [0.08 ... 0.8 inWC] | ±8 Pa [±0.03 inWC] | ±15% | 20 Pa [0.08 inWC] | |
| 30 ... 300 Pa [0.12 ... 1.20 inWC] | ±8 Pa [±0.03 inWC] | ±15% | 25 Pa [0.10 inWC] | |
| 30 ... 500 Pa [0.12 ... 2.00 inWC] | ±8 Pa [±0.03 inWC] | ±15% | 25 Pa [0.10 inWC] | |
| 40 ... 600 Pa [0.16... 2.41 inWC] | ±8 Pa [±0.03 inWC] | ±15% | 35 Pa [0.14 inWC] | |
| 100 ... 1,500 Pa [0.40 ... 6.02 inWC] | ±20 Pa [±0.08 inWC] | ±15% | 80 Pa [0.32 inWC] | |
| 500 ... 4,500 Pa [2.00 ... 18.08 inWC] | ±100 Pa [±0.40 inWC] | ±15% | 250 Pa [1.00 inWC] | |
| Unit | ■ Pa ■ kPa ■ inWC ■ mmWC ■ mbar | |||
| Maximum operating pressure | ■ Test pressure: 25 kPa [100 inWC] ■ Burst pressure: 50 kPA [200 inWC] | |||
| Process connection | Connecting nozzle, side mount, for hoses with inner diameter 4 ...6 mm[0.16 ries') | …0.24 in] (see 'Accesso - | ||
| Electrical connection | Cable gland M16 Screw terminals max.1.5mm ² [0.002 in²] | |||
| Switching power | ||||
| Voltage | Pressure range 20 ... 200 Pa | All other pressure ranges | ||
| Resistive load (cos φ≈1) | Resistive load (cos φ≈1) | Inductive load (cos φ≈0.6 - 0.7) | ||
| AC 125V | 0.1 A | 3 A | 2 A | |
| AC 250V | 0.1 A | 3 A | 2 A | |
| DC 30V | 0.1 A | 3 A | 2 A | |
| DC 125V | - | 0.4 A | 0.05 A | |
| Mounting type | Wall mounting | |||
| Materials | ||||
| Case | Plastic (ABS) | |||
| Window | Polycarbonate (PC) | |||
| Diaphragm | Silicone | |||
| Seals | Plastic | |||
| Permissible temperatures | ||||
| Medium | -20 ...+60 °C [-4 …+140 °F] | |||
| Ambient | -20 ...+85 °C [-4 …+185 °F] | |||
| Relative humidity, condensation | 0 ... 95 %r.h., non-condensing | |||
| Ingress protection per IEC/EN 60529 | IP54 | |||
| Weight | 150 g [0.33 lbs] |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity | European Union | |
| LowVoltage Directive | ||
| RoHS conformity | ||
| WEEE directive | ||
| EAC | Eurasian Economic Community G | |
| EMCdirective | H | |
| LowVoltage Directive | I |
Certificates
| Certificates | 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, material proof, indication accuracy) |
|---|
Dimensions in mm[in]
| A | B | C | D | E | Ø F | G | H | I | J | K | L | M | N | O | P |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 73 | M N 15.1 | 10.2 | 5.5 | 9.5 | 4 | 73 | 52.7 | 5.6 | 3.9 | 94 | 107 | 10.15 | 7.05 | 16 | 63 |
| [2.87] | [0.59] | [0.39] | [0.2] | [0.37] | [0.16] | [2.87] | [2.05] | [0.2] | [0.15] | [3.70] | [4.21] | [0.39] | [0.28] | [0.63] | [2.48] |
View all (5)
| Description | Order number |
|---|---|
| Measuring hoses | |
| PVC hose, inner diameter 4 mm[0.15 in], roll at 25 m[19.68 ft] | 40217841 |
| PVC hose, inner diameter 6 mm[0.23 in], roll at 25 m[19.68 ft] | 40217850 |
| Silicone hose, inner diameter 4 mm[0.15 in], roll at 25 m[19.68 ft] | 40217906 |
| Silicone hose, inner diameter 6 mm[0.23 in], roll at 25 m[19.68 ft] | 40217914 |
| Duct connectors for measuring hoses Ø 4 …6mm[0.16 …0.24 in] | 40217507 |
Industry
Machinery
Overpressure monitoring in clean rooms and laboratories
Industry
Heating / Utilities
Monitoring of ventilators, blowers and filters in air-conditioning and clean room applications