Air flow meter
Description
The model A2G-25 air flow meter is used for measuring air flows of gaseous media in ventilation and air-conditioning applications.
The air flow is measured by determining the differential pressure and multiplying it with the K factor. The K factor depends on the ventilator used or, when using pipe/duct measuring probes, on the size and number of probes and is easy and fast to enter in the menu. The different calculation formulas for the air flow are already programmed in the menu of the A2G-25. By choosing the respective radial ventilator manufacturer, the correct formula is automatically taken into account in the calculation.
for further approvals see page 4
w
F
l
o
Air flow meter, model A2G-25
Electrical analogue output signals for both measurands (DC 0 … 10 V or 4 … 20 mA) or the digital Modbus ® versions enable the direct connection to control systems or the building automation system.
The measured differential pressure is also shown on the LC display and transmitted via the analogue or digital output signals. Thus the A2G-25 combines two measurements in one instrument. The LC display and the clear menu navigation enable a time-saving and simple commissioning.
With the A2G-25, air flows up to 200,000 m 3 /h and differential pressures up to 7,000 Pa can be measured.
Special features
- With analogue output signal (0 … 10 V or 4 … 20 mA) or Modbus ® protocol
- Output signal for air flow and differential pressure in one instrument
- Simple and fast mounting and commissioning
- Maintenance-free
- Maximum operating pressure 20 kPa
| Model | A2G-25 |
| Product family | A2G |
| Subcategory | differential pressure-based air flow meter |
| Flow ranges | 0…1000 Pa · 0…2000 Pa · 0…5000 Pa · 0…7000 Pa · 0…2500 Pa |
| Accuracy | 1 % |
| Process connection | Connecting nozzle (ABS), lower mount, for hoses with inner diameter 4 … 6 mmConnecting nozzle (ABS), lower mount, for hoses 4…6mm with inner diameter |
| Process temperature | −20…+50 °C |
| Max process pressure | 0.2 bar |
| Measurement technology | variable_area |
| Output signal | Modbus RTU · DC 0 … 10 V · 4 … 20 mA · Modbus® |
| Power supply | AC 24 V or DC 24 V ±10 % |
| Wetted parts material | ABS, PC |
| Ambient temperature | −40…+70 °C |
| IP rating | IP54 |
| Weight | 0.15 kg |
| Certifications | RoHSWEEECEEACGOSTKazInMetrMTSCHS |
| Datasheet languages | EN, DE |
| Air flow meter, model A2G-25 | ||
|---|---|---|
| Measuring element | Piezo measuring cell | |
| Measuring range | ||
| Analogue output signal (DC 0 …10V/4 …20mA) | ■ 0 ... 1,000 Pa 1) ■ 0 ... 2,000 Pa ■ 0 ... 5,000 Pa ■ 0 ... 7,000 Pa | |
| Modbus ® version | ■ 0 ... 2,500 Pa ■ 0 ... 7,000 Pa | |
| Accuracy 2) | ||
| Measuring ranges 0 …1,000, 0 …2,000, 0 …2,500 Pa | Pressure < 125 Pa Pressure > 125 Pa | 1 %±2Pa 1 %±1Pa |
| Measuring ranges 0 …5,000, 0 …7,000 Pa | Pressure < 125 Pa | 1.5 %±2Pa |
| Units (adjustable in the menu) | ||
| Air flow | ■ m 3 /h ■ m 3 /s ■ l/s ■ cfm | |
| Differential pressure | ■ Pa ■ kPa ■ mbar ■ inWC ■ mmWC | |
| Process connection | Connecting nozzle (ABS), lower mount, for hoses 4…6mm | with inner diameter |
| Supply voltage U B | AC 24V or DC 24V | ±10% |
| Electrical connection | Cable gland M16 Cover:PG Screw terminals | max.1.5mm 2 |
| Output signal | ||
| Voltage | V OUT P OUT Minimum load | DC0…10V DC0…10V 1 kΩ |
| Current | V OUT P OUT Minimum load | 4…20mA 4…20mA 500Ω |
| Modbus® | See page 3 | |
| Current consumption | ||
| DC0…10V | < 1.0W | |
| 4…20mA | < 1.2W | |
| Modbus ® | < 1.3W | |
| Case | Plastic (ABS) Cover: Polycarbonate | (PC) |
| Mounting | Wall mounting | |
| Zero point setting | ■ Automatic 3) | button on the printed circuit board |
| Permissible temperatures | ||
| Medium | ■ -20 …+50 °C [-4 …+122 °F] ■ -5 …+50 °C [23 …122 °F], with automatic zero point setting | |
| Ambient | -40 …+70 °C [-40 …+158 °F] | |
| Ingress protection per IEC/EN 60529 | IP54 | |
| Weight | 150 g |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity ■ EMCdirective ■ RoHS directive ■ WEEE directive | European Union | |
| EAC (option) ■ Import certificate ■ EMCdirective | Eurasian Economic Community | |
| GOST (option) Metrology, measurement technology | Russia | |
| KazInMetr (option) Metrology, measurement technology | Kazakhstan | |
| - | MTSCHS (option) Permission for commissioning | Kazakhstan |
| Description | Order number |
|---|---|
| Measuring hoses | |
| PVC hose, inner diameter 4 mm, roll at 25m | 40217841 |
| PVC hose, inner diameter 6 mm, roll at 25m | 40217850 |
| Silicone hose, inner diameter 4 mm, roll at 25m | 40208940 |
| Silicone hose, inner diameter 6 mm, roll at 25m | 40208958 |
| Duct connectors for measuringhosesØ4…6mm | 40217507 |
| Measuring probe for air flow measurement with pitot tube Model A2G-FM, see data sheet SP 69.10 | - |
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →