Adapter system for measuring instruments with G1 hygienic connection
Description
The WIKA process adapter system has been specifically developed to meet the requirements of the food, beverage and pharmaceutical industries. The adapter system consists of the measuring instrument with G1 hygenic connection and matching process adapter.
The flexible, modular system allows connection to a wide range of aseptic process connections (e.g. clamp, threaded, VARIVENT® or NEUMO®).
All parts are made of stainless steel 1.4435 (316L); UNS S31603
The O-ring for sealing the process (optional) is supplied with a 3.1 material certificate per EN 10204. It is available in either EPDM or FKM and is listed as FDA, USP class VI, as well as 3-A 18-03.
The WIKA adapter system meets the high requirements of sterile processes.
Measuring instrument and process adapter are easily connected and disconnected using a spanner.
Fig. top: Model S-11 pressure transmitter with
G1 hygienic connection
Fig. centre: VARIVENT® process adapter
Fig. bottom: Clamp process adapter
Special features
- Large selection of different process adapters for connection to the G1 hygienic connection
- Measuring instrument and process adapters can be combined by the user
| Model | 910.61 |
| Product family | 910 |
| Subcategory | Process adapter |
| Pressure ranges | 0…40 bar · 0…25 bar · 0…16 bar |
| Process connection | DRDNEUMO BioControl®VARIVENT® form FVARIVENT® form NClampVARIVENT®DIN 11851DIN 11864SMSIDFAPV-RJTWeld-inClamp DN 33.7, 42.4, 48.3, 60.3Clamp DN 1 ½", 2", 2 ½"Clamp per ISO 2852 DN 33.7 - 51Clamp per DIN 32676 for DIN 11850Thread DIN 11851Thread IDFDIN 11864-1 form ADIN 11864-2 form ADIN 11864-3 form AWeld-in connection Ø50mmThread SMSThread APV-RJTClamp per DIN 32676Clamp per ISO 2852Thread per DIN 11851Thread per SMSThread per IDFThread per APV-RJTAseptic threaded DIN 11864-1Aseptic flange DIN 11864-2Aseptic clamp DIN 11864-3Weld-in connection |
| Process temperature | −40…+200 °C |
| Case material | Stainless steel 1.4435 (316L), UNS S31603 |
| Wetted parts material | Stainless steel 1.4435 (316L), UNS S31603 |
| Sealing material | EPDM, FKM |
| Certifications | 3-AEHEDGFDAUSP Class VI |
| Datasheet languages | EN, DE |
| Material | Colour | Temperature range | Conformity to | Order no. |
|---|---|---|---|---|
| EPDM 70 | black | -40 ...+145 °C | FDA 21 CFR 177.2600, USP XXV Class VI and 3-A (18-03) Sanitary Standards class 2 (max. 8 %milk fat) | 14004173 |
| FKM 75 | black | -15 ...+200 °C | FDA 21 CFR 177.2600, USP XXIII class VI and 3-A (18-03) Sanitary Standards class 1 | 14004174 |
| 3-A compliant process connection | Size | Nominal pressure |
|---|---|---|
| Clamp connection per DIN 32676 for pipes per DIN 11866 row C or ASME BPE, DN 1 1/2" | DN 33.7, 42.4, 48.3, 60.3 | PN 40 |
| Clamp connection per DIN 32676 for pipes per DIN 11866 row C or ASME BPE | DN 1 ½", 2", 2 ½" | PN 40 |
| Clamp connection for pipes per BS4825 part 3 and O.D. tube | DN 1 ½", 2", 2 ½" | PN 40 |
| Clamp connection per ISO 2852 for pipes per ISO 2037 and BS4528 part 1 | DN 33.7 - DN 51 | PN 40 |
| Clamp connection per DIN 32676 for pipes per DIN 11850 | DN 32, 40, 50 | PN 40 |
| Thread per DIN 11851 with grooved union nut | DN 32, 40, 50 | PN 25/40 |
| Thread per IDF standard with grooved union nut | DN 1 ½", 2" | PN 40 |
| VARIVENT ® form F (EHEDG) | Ø50mm | PN 25 |
| VARIVENT ® form N (EHEDG) | Ø68mm | PN 25 |
| DRD | Ø65mm | PN 40 |
| NEUMO BioControl ® | Size 50, 65, 80 | PN 16 |
| Aseptic threaded connection DIN 11864-1 form A BS & GS (EHEDG) | DN 32, 40, 50 | PN 25/40 |
| Aseptic flange connection DIN 11864-2 form A NF & BF (EHEDG) | DN 32, 40, 50 | PN 25/40 |
| Aseptic clamp connection DIN 11864-3 form A BKS & NKS (EHEDG) | DN 32, 40, 50 | PN 25/40 |
| Weld-in connection (for welding to tanks) | Ø50mm | PN 40 |
| Process connection | Size | Nominal pressure |
| Thread per SMS standard with grooved union nut | DN 1 ½", 2" | PN 40 |
| Thread per APV-RJT standard with union nut | DN 1 ½", 2" | PN 40 |
| DN | For pipe Outer Ø x wall thickness | PN 1) | Dimensions inmm D | Order no. |
|---|---|---|---|---|
| 33.7 | 33.7 x 2 | 40 | 50.5 | 14024493 |
| 42.4 | 42.4 x 2 | 40 | 64 | 14024574 |
| 48.3 | 48.3 x 2 | 40 | 64 | 14024575 |
| 60.3 | 60.3 x 2 | 40 | 77.5 | 14024587 |
| DN | For pipe Outer Ø x wall thickness | PN 1) | Dimensions inmm D | Order no. |
|---|---|---|---|---|
| 1 ½" | 38.1 x 1.6 | 40 | 50.5 | 14024552 |
| 2" | 50.8 x 1.6 | 40 | 64 | 14024577 |
| 2 ½" | 50.8 x 1.6 | 40 | 77.5 | 14024590 |
View all (19)
| DN | For pipe Outer Ø x wall thickness | PN 1) | Dimensions inmm D | Order no. |
|---|---|---|---|---|
| 33.7 | 33.7 x 1.2 | 40 | 50.5 | 14024558 |
| 38 | 38 x 1.2 | 40 | 50.5 | 14024566 |
| 40 | 40 x 1.2 | 40 | 64 | 14024582 |
| 51 | 51 x 1.2 | 40 | 64 | 14024586 |
| 63.5 | 63.5 x 1.6 | 40 | 77.5 | 14024591 |
| DN | For pipe Outer Ø x wall thickness | PN 1) | Dimensions inmm D | Order no. |
|---|---|---|---|---|
| 32 | 34 x 1 | 40 | 50.5 | 14024555 |
| 40 | 40 x 1 | 40 | 50.5 | 14024572 |
| 50 | 52 x 1 | 40 | 64 | 14024584 |
| DN | For pipe Outer Ø x wall thickness | PN 1) | Dimensions inmm D | G | h 1 | SW | Order no. |
|---|---|---|---|---|---|---|---|
| 32 | 35 x 1.5 | 40 | 50 | Rd58x1/6 | 10 | 36 | 14024465 |
| 40 | 41 x 1.5 | 40 | 56 | Rd65x1/6 | 10 | 41 | 14024477 |
| 50 | 53 x 1.5 | 25 | 68.5 | Rd78x1/6 | 11 | 55 | 14024487 |
| DN | For pipe Outer Ø x wall | PN 1) | Dimensions inmm Order no. | |||
|---|---|---|---|---|---|---|
| thickness | D | G | SW | |||
| 1 ½" | 38 x 1.2 | 40 | 55 | Rd60x1/6 | 41 | 14024488 |
| 2" | 51 x 1.2 | 40 | 65 | Rd70x1/6 | 46 | 14024489 |
| DN | For pipe Outer Ø x | PN | Dimensions inmm | |||
|---|---|---|---|---|---|---|
| wall thick- ness | 1) | d ₂ | D | G | SW | |
| 1 ½" | 38.1 x 1.6 | 40 | 40.5 | 54 | 2 5 / 16 x 8 " | 41 |
| 2" | 50.8 x 1.6 | 40 | 53.2 | 66.7 | 2 7 / 8 x 6 " | 46 |
| DN | Order no. |
|---|---|
| 1½" | 14024490 |
| 2" | 14024492 |
| Access unit connection | PN 1) | Dimensions inmm | Order no. | |
|---|---|---|---|---|
| d ₁ | D | |||
| Form F | 25 | 50 | 66 | 14024594 |
| Form N | 25 | 68 | 84 | 14024596 |
| Connection | PN | Order no. |
|---|---|---|
| DRD | 40 | 14024670 |
| Size | PN 1) | Dimensions inmm | |||||
|---|---|---|---|---|---|---|---|
| d 4 | k | f | H | d ₂ | D | ||
| Size 50 | 16 | 50 | 70 | 17 | 27 | 4 x 9 | 90 |
| Size 65 | 16 | 68 | 95 | 17 | 27 | 4 x 9 | 120 |
| Size 80 | 16 | 87.5 | 115 | 25 | 37 | 4 x 11 | 140 |
| Size | Order no. |
|---|---|
| Size 50 | 14024633 |
| Size 65 | 14024634 |
| Size 80 | 14024635 |
| DN | For pipe Outer Ø x wall thickness | PN 1) | Dimensions inmm | Order no. | ||
|---|---|---|---|---|---|---|
| 32 | 35 x 1.5 | 40 | d₆ 48.9 | G Rd58x 1 / 6 | SW 36 | 14024636 |
| 40 | 41 x 1.5 | 40 | 54.9 | Rd65x 1 / 6 | 41 | 14024638 |
| 50 | 53 x 1.5 | 25 | 66.9 | Rd78x 1 / 6 | 55 | 14024641 |
| DN | For pipe Outer Ø x wall thickness | PN 1) | Dimensions inmm | Order no. | ||
|---|---|---|---|---|---|---|
| 32 | 35 x 1.5 | 40 | d 11 49 | G Rd58x 1 / 6 | SW 41 | 14024637 |
| 40 | 41 x 1.5 | 40 | 55 | Rd65x 1 / 6 | 50 | 14024639 |
| 50 | 53 x 1.5 | 25 | 67 | Rd78x 1 / 6 | 60 | 14024643 |
| DN | For pipe Outer Ø x wall thickness | PN 1) | Dimensions inmm d 6 D | Order no. | |
|---|---|---|---|---|---|
| 32 | 35 x 1.5 | 40 | 47.6 | 50.5 | 14024663 |
| 40 | 41 x 1.5 | 40 | 53.6 | 64 | 14024666 |
| 50 | 53 x 1.5 | 25 | 65.6 | 77.5 | 14024668 |
| DN | For pipe Outer Ø x wall thickness | PN 1) | Dimensions inmm d 4 D | Order no. | |
|---|---|---|---|---|---|
| 32 | 35 x 1.5 | 40 | 47.7 | 50.5 | 14024661 |
| 40 | 41 x 1.5 | 40 | 53.7 | 64 | 14024665 |
| 50 | 53 x 1.5 | 25 | 65.7 | 77.5 | 14024667 |
| Version | PN | Order no. |
|---|---|---|
| Weld-in connection with leak-control channel | 40 | 14070974 |
| Weld-in connection without leak-control channel | 40 | 14070973 |
Couldn't find the answer in the documentation? An engineer will reply within a business day.