WIKA · Pressure measurement · Family 910
Cooling element for pressure measuring instruments
Cooling element for pressure measuring instruments with 3 or 5 cooling fins for threaded attachment, suitable for medium temperatures up to 200 °C and pressures up to 600 bar.
Range
0…600 bar
Price
On request
Depends on configuration
Description
Cooling elements are used when the medium temperature would exceed the permissible temperature limit of the pressure measuring instrument.
Through air circulation and heat radiation at the cooling element, the medium temperature is lowered sufficiently so that the temperature limits are not exceeded and any possible temperature error is reduced.
The cooling element can also be used for warming very cold media, provided that the ambient temperature is higher than that of the media.
Special features
- For medium temperatures up to 200 °C
- Can work with pressures up to 600 bar
- Connections for G ½ B (EN 837)
Identification
| Model | 910.32 |
| Product family | 910 |
| Subcategory | Cooling element |
Measuring range
| Pressure ranges | 0…600 bar |
Accuracy
| Accuracy standard | EN 837 |
Process conditions
| Process connection | G ½ B (EN 837)G 1/2 B (EN 837)G 1/2 B female (EN 837) |
| Process temperature | +0…+200 °C |
Materials
| Case material | Stainless steel 1.4571 |
| Wetted parts material | Stainless steel 1.4571 |
Operating environment
| Weight | 0.2 kg |
Additional details
| Datasheet languages | EN, DE |
Tables from datasheet
| Selectable versions Max.medium temperature | Process connection | Measuring instrument connection | Order no. |
|---|---|---|---|
| 150 °C (3 cooling fins) | G½B(EN837) | G½Bfemale (EN 837) | 14109813 |
| 200 °C (5 cooling fins) | G½B(EN837) | G½Bfemale (EN 837) | 14109815 |
| G1 | G2 | L1 | L2 | L3 | L4 |
|---|---|---|---|---|---|
| G½B(EN837) | G½Bfemale (EN 837) | 53.5 | 23 | 19 | 20 |
| G1 | G2 | L1 | L2 | L3 | L4 |
|---|---|---|---|---|---|
| G½B(EN837) | G½Bfemale (EN 837) | 63.5 | 23 | 19 | 20 |
Industry
Machinery
For screwing onto pressure measuring instruments at increased medium temperatures
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →