WIKA · Pressure measurement · Family 910
Pre-volume deflagration flame arrester
For mounting to zone 0 (EPL Ga)
Range
0…16 bar
Accuracy
1.0
CERoHSIECExREACHIECEx IICATEX II G IICATEXII G IIC
Price
On request
Depends on configuration
Description
The model 910.21 pre-volume deflagration flame arrester enables the mounting of pressure measuring instruments and diaphragm seal systems in areas with requirements to EPL Ga (zone 0).
The model 910.21 is expertly connected to a measuring instrument at the factory to form a measuring assembly. The pre-volume deflagration flame arrester enables the flow of fluids, but prevents the flame tranmission from the instrument side (unprotected side) to the process side (protected side) in the event of a failure.
Special features
- Fulfils the requirements of flame arresters in accordance with EN ISO 16852
- With ATEX and IECEx approval
Identification
| Model | 910.21 |
| Product family | 910 |
| Subcategory | Flame arrester |
Measuring range
| Pressure ranges | 0…16 bar |
Accuracy
| Accuracy class | 1.0 |
| Accuracy standard | EN ISO 16852:2016 |
Process conditions
| Process temperature | −40…+60 °C |
Materials
| Wetted parts material | Stainless steel, Monel, Hastelloy, 316L |
Operating environment
| Ambient temperature | −40…+60 °C |
Certifications and approvals
| Certifications | CERoHSIECExREACH |
| Explosion protection | IECEx IICATEX II G IICATEXIECExII G IIC |
Additional details
| Datasheet languages | EN |
Tables from datasheet
Basic information
| Standard | EN ISO 16852:2016 'Flame arresters …' |
|---|---|
| Measuring assembly | |
| Variant 1 | Pressure gauge with Ex approval and integrated model 910.21 |
| Variant 2 | Diaphragm seal system 1) with integrated model 910.21 |
| Permissible media | Flammable gases and vapours occurring during operation may be classified into explosion group IIC with a nominal gap width of ≥ 0.29 mm.The use for explosive gas, mist, vapour or air mixtures which are volatile (e.g. acetylene, carbon disulfide) or for chemically instable substances is not permitted. |
| Material (wetted) | |
| Variant 1 | ■ Stainless steel (typically) ■ Special materials such as the wetted parts of the pressure gauge, e.g. Monel, Hastelloy |
| Variant 2 | Model 910.21 is non-wetted |
| Components of the measuring assembly | Mounting parts, such as cooling elements, connection adapters, capillaries, etc., are located on the protected process side. Measuring assemblies with capillaries are, generally, protected ex-works with a capillary protective tube (wall thickness approx. 0.2 mm). |
Further details on: Measuring assembly, variant 1 Pressure gauge with Ex approval and integrated model 910.21
| Pressure gauge with Ex approval | ■ Pressure gauge (e.g. models 232.50, 432.50, 732.51) ■ Contact pressure gauge (e.g.PGS23, PGS43, DPGS43) ■ Pressure gauge with output signal (e.g.PGT23, PGT43, DPGT43) |
|---|
Further details on: Measuring assembly, variant 2 Diaphragm seal system with integrated model 910.21
| Pressure measuring instrument with Ex approval | ■ Pressure gauge (e.g. models 232.50, PGS43, DPGT43) ■ Model CPG1500 ■ Model IS-3 ■ Model UPT-20 ■ Model IPT-20 ■ Model DPT-10 |
|---|---|
| Diaphragm seal | ■ Diaphragm seal with flange connection ■ Diaphragm seal with threaded connection ■ In-line diaphragm seal ■ Diaphragm seal with sterile connection |
Operating conditions
| Lu/D=n/a | Ratio of the pipe length of the unprotected side to the pipe diameter |
|---|---|
| BC:c | Classification under stabilised combustion, combustion classification c (no burn time) |
| -40 °C ≤ T 0 ≤ 60 °C | Permissible operating temperature The measuring point for the permissible temperature in the final application is the position symbol of the zone separation. |
| P 0 = 1.1 bar | Maximum ambient pressure |
View all (5)
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity Hazardous areas II GIIC | European Union | |
| IECEx Hazardous areas IIC | International |
Industry
Machinery
Integrated into a pressure measuring instrument or diaphragm seal system
Couldn't find the answer in the documentation? An engineer will reply within a business day.