AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
910.21 1
910.21
On order
WIKA · Pressure measurement · Family 910

Pre-volume deflagration flame arrester

For mounting to zone 0 (EPL Ga)
Range
0…16 bar
Accuracy
1.0
CERoHSIECExREACHIECEx IICATEX II G IICATEXII G IIC
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The model 910.21 pre-volume deflagration flame arrester enables the mounting of pressure measuring instruments and diaphragm seal systems in areas with requirements to EPL Ga (zone 0).

The model 910.21 is expertly connected to a measuring instrument at the factory to form a measuring assembly. The pre-volume deflagration flame arrester enables the flow of fluids, but prevents the flame tranmission from the instrument side (unprotected side) to the process side (protected side) in the event of a failure.

Special features

  • Fulfils the requirements of flame arresters in accordance with EN ISO 16852
  • With ATEX and IECEx approval
Identification
Model910.21
Product family910
SubcategoryFlame arrester
Measuring range
Pressure ranges0…16 bar
Accuracy
Accuracy class1.0
Accuracy standardEN ISO 16852:2016
Process conditions
Process temperature−40…+60 °C
Materials
Wetted parts materialStainless steel, Monel, Hastelloy, 316L
Operating environment
Ambient temperature−40…+60 °C
Certifications and approvals
Certifications
CERoHSIECExREACH
Explosion protection
IECEx IICATEX II G IICATEXIECExII G IIC
Additional details
Datasheet languagesEN
Tables from datasheet
Basic information
StandardEN ISO 16852:2016 'Flame arresters …'
Measuring assembly
Variant 1Pressure gauge with Ex approval and integrated model 910.21
Variant 2Diaphragm seal system 1) with integrated model 910.21
Permissible mediaFlammable gases and vapours occurring during operation may be classified into explosion group IIC with a nominal gap width of ≥ 0.29 mm.The use for explosive gas, mist, vapour or air mixtures which are volatile (e.g. acetylene, carbon disulfide) or for chemically instable substances is not permitted.
Material (wetted)
Variant 1■ Stainless steel (typically) ■ Special materials such as the wetted parts of the pressure gauge, e.g. Monel, Hastelloy
Variant 2Model 910.21 is non-wetted
Components of the measuring assemblyMounting parts, such as cooling elements, connection adapters, capillaries, etc., are located on the protected process side. Measuring assemblies with capillaries are, generally, protected ex-works with a capillary protective tube (wall thickness approx. 0.2 mm).
Further details on: Measuring assembly, variant 1 Pressure gauge with Ex approval and integrated model 910.21
Pressure gauge with Ex approval■ Pressure gauge (e.g. models 232.50, 432.50, 732.51) ■ Contact pressure gauge (e.g.PGS23, PGS43, DPGS43) ■ Pressure gauge with output signal (e.g.PGT23, PGT43, DPGT43)
Further details on: Measuring assembly, variant 2 Diaphragm seal system with integrated model 910.21
Pressure measuring instrument with Ex approval■ Pressure gauge (e.g. models 232.50, PGS43, DPGT43) ■ Model CPG1500 ■ Model IS-3 ■ Model UPT-20 ■ Model IPT-20 ■ Model DPT-10
Diaphragm seal■ Diaphragm seal with flange connection ■ Diaphragm seal with threaded connection ■ In-line diaphragm seal ■ Diaphragm seal with sterile connection
Operating conditions
Lu/D=n/aRatio of the pipe length of the unprotected side to the pipe diameter
BC:cClassification under stabilised combustion, combustion classification c (no burn time)
-40 °C ≤ T 0 ≤ 60 °CPermissible operating temperature The measuring point for the permissible temperature in the final application is the position symbol of the zone separation.
P 0 = 1.1 barMaximum ambient pressure
View all (5)
LogoDescriptionCountry
EU declaration of conformity Hazardous areas II GIICEuropean Union
IECEx Hazardous areas IICInternational