WIKA · Pressure measurement · Family 904
Control unit
For pointer instruments with inductive contacts
Output
Relay output
Protection
IP20
CERoHSI (M1) II (1) D II (1) GI (M1) II (1) D II (1)GI(M1)II(1)DII(1)G
Price
On request
Depends on configuration
Description
The model 904 control unit is used in combination with model 831 inductive contacts. The control unit consists of a power supply unit, a control element, a switching amplifier and a relay output. Certain versions are approved for the operation of inductive contacts in Ex areas.
Special features
- Versions for Ex areas available
- 1 or 2 potential-free change-over contacts
- Case for DIN-rail mounting
Identification
| Model | 904 |
| Subcategory | Control unit |
Electrical characteristics
| Output signal | Relay output · Relay output (SPDT) · DC 24 V voltage output |
| Power supply | AC 230 V, -10...+6%; AC 115 V, -10...+6%; AC 24 V, -10...+6%; DC 24 V, -10...+15% |
| Electrical connection | Screw terminals |
| Switching function | Change-over contact |
| Switching contacts | 1 |
Materials
| Case material | Polycarbonate (PC), Polyamide 6.6, Polyamide 6.6, red/black |
Operating environment
| Ambient temperature | +0…+70 °C |
| IP rating | IP20 |
| Weight | 0.24 kg |
Certifications and approvals
| Certifications | CERoHS |
| Explosion protection | I (M1) II (1) D II (1) GI(M1)II(1)DII(1)G |
Additional details
| Datasheet languages | EN |
Tables from datasheet
| Specifications | Model 904.28 KFU8-SR-Ex1.W | Model 904.29 KFU8-SR-Ex2.W | Model 904.33, safety equipment KFD2-SH-Ex1 |
|---|---|---|---|
| Voltage supply | DC 19 ...30V or AC 90 ... 253 V, 50 ... 60 Hz | DC 19 ...30V or AC 90 ... 253 V, 50 ... 60 Hz | DC 20 ...35V |
| Power consumption | DC: ≤ 1Wor AC:3VA | DC: ≤ 1Wor AC:3VA | 2.3VA |
| Input | |||
| Quantity | 1 | 2 | 1 |
| Open-circuit voltage | DC 8V | DC 8V | DC 8.4V |
| Short-circuit current | 8mA | 8mA | 11.7mA |
| Switch point | 1.2 mA≤Is ≤ 2.1mA | 1.2 mA≤Is ≤ 2.1mA | 2.1 mA≤Is ≤ 5.9mA |
| Switch hysteresis | Approx.0.2mA | Approx.0.2mA | Approx.0.6mA |
| Control line resistance | 100Ω | 100Ω | ≤ 50Ω |
| Safety-related characteristic values (Ex) | |||
| Max. voltage U 0 | DC 10.5V | DC 10.5V | DC 9.56V |
| Max. current I 0 | 13mA | 13mA | 16.8mA |
| Max. power P 0 | 34mW | 34mW | 41mW |
| Perm. external capacitance | 2.41 µF | 2.41 µF | 650 nF |
| Perm. external inductance | 210mH | 210mH | 5mH |
| Ex marking | I (M1) II (1) D II (1)G | I (M1) II (1) D II (1)G | I (M1) II (1) D II (1)G |
| Output signal | |||
| Relay output | 1 x SPDT (single pole double throw) | 2 x SPDT (single pole double throw) | 1 safety-related relay output |
| Load capacity AC | 250 V, 2 A, 500 VA, cos ϕ > 0.75 | 250 V, 2 A, 500 VA, cos ϕ > 0.75 | 50 V, 1 A, cos ϕ > 0.7 |
| Load capacity DC | 40 V, 2 A; resistive load | 40 V, 2 A; resistive load | 24 V, 1 A; resistive load |
| Pick-up delay | Approx. 20 ms | Approx. 20 ms | ≤ 1 ms |
| Drop-out delay | Approx. 20 ms | Approx. 20 ms | ≤ 1 ms |
| Max. switching frequency | 10 Hz | 10 Hz | 5 Hz |
| Ambient conditions | |||
| Operating temperature range | -40 ... 60 °C [-4 ... 140 °F] | -40 ... 60 °C [-4 ... 140 °F] | -20 ... 60 °C [-4 ... 140 °F] |
| Perm. relative humidity | ≤ 95 %, non-condensing | ≤ 95 %, non-condensing | ≤ 95 %, non-condensing |
| Ingress protection per IEC/EN 60529 | IP20 | IP20 | IP20 |
| Case | |||
| Design | Suitable for DIN rail per EN 60715,TH 35 | ||
| Material | Polycarbonate (PC) | Polycarbonate (PC) | Polycarbonate (PC) |
| Dimensions | Form D, see page 7 | Form F, see page 7 | Form E, see page 7 |
| Weight | Approx. 0.15 kg [0.33 lb] | Approx. 0.15 kg [0.33 lb] | Approx. 0.28 kg [0.62 lb] |
| Order number | 14692440 | 14692453 | 2307618 |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity | European Union | |
| EMCdirective | ||
| Low voltage directive | ||
| RoHS directive (only models 904.28, 904.29 and 904.33) |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity ATEX directive Hazardous areas | European Union |
Industry
Oil & Gas
Machine building, general plant construction, chemical industry, petrochemical industry, power plants, mining, on-/offshore and environmental technology
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →