Differential pressure gauge
Description
The compact differential pressure gauge, model 716.05 with a nominal size of 80 mm , has been specifically designed for measuring points at which differential pressure measurements with low differential pressures take place. In addition, an overload safety of up to 16 bar is guaranteed, on either side.
Depending on the accuracy classes of 2.5 % and 4 %, different scale ranges can be specified. Differential pressures of 0 to 16 mbar and 0 to 600 mbar can be measured.
for further approvals see page 3
Differential pressure gauge model 716.05
The differential pressure gauge offers a wide variety of connection options, as well as panel mounting, and can therefore be used in many applications for level measurement.
Special features
- Differential pressure measuring ranges from 0 … 16 mbar
- High working pressure (static pressure) and high overload safety up to 16 bar
- Numerous options for installation, connection form and connection location
| Model | 716.05 |
| Product family | 716 |
| Subcategory | Differential pressure gauge |
| Pressure ranges | 0…16 mbar · 0…25 mbar · 0…40 mbar · 0…600 mbar |
| Accuracy class | 2.5, 4.0 |
| Accuracy standard | EN 837-1 |
| Process connection | G ⅛ female |
| Process temperature | −15…+70 °C |
| Case material | Aluminium |
| Wetted parts material | Stainless steel, Copper alloy, Aluminium, Argentan |
| Sealing material | NBR, Silicone rubber |
| Ambient temperature | −15…+60 °C |
| IP rating | IP66 |
| Weight | 0.64 kg |
| Certifications | EACGOSTMTSCHSUkrSEPROUzstandardCPACRN |
| Dial size | 80 mm |
| Datasheet languages | EN |
| Logo | Description | Country |
|---|---|---|
| EAC (option) Pressure equipment directive | Eurasian Economic Community | |
| GOST Metrology, measurement technology | Russia | |
| - | MTSCHS (option) Permission for commissioning | Kazakhstan |
| UkrSEPRO Metrology, measurement technology | Ukraine | |
| Uzstandard (option) Metrology, measurement technology | Uzbekistan | |
| - | CPA Metrology, measurement technology | China |
| - | CRN Safety (e.g. electr. safety, overpressure, ...) | Canada |
Couldn't find the answer in the documentation? An engineer will reply within a business day.