AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
632.51 1
632.51
On order
WIKA · Pressure measurement · Family 632

Capsule pressure gauge, stainless steel

For the process industry, high overload safety, NS 100 [4"] and 160 [6"]
Range
-100…100 mbar
Accuracy
1.6
Protection
IP54
CRNUKCAEACMChSPACATEXEx UkrainePAC KazakhstanPAC UkrainePAC UzbekistanPAC ChinaCEEACExATEX II 2G h IIC T6 ... T1 Gb XEAC ExEx Ukraine Hazardous areasMChS Kazakhstan
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

These capsule pressure gauges are used when extremely-low pressures must be displayed on site. The instruments can be overloaded up to 50 times the full scale value without any problems.

The large effective area of the two welded, radially corrugated diaphragms of the capsule element allows the reliable measurement of the smallest pressures. These measuring instruments, made entirely of stainless steel, are suitable for gaseous, aggressive media.

The capsule pressure gauge of model 632.51 has been qualified and manufactured in accordance with EN 837-3.

Capsule pressure gauge, model 632.51

Special features

  • High overload safety up to 50 x full scale value
  • Scale ranges from 0 … 2.5 mbar
  • Measuring chamber protected against unauthorised intervention
  • Low measuring error and influence on function from medium pollution
Identification
Model632.51
Product family632
SubcategoryCapsule pressure gauge
Measuring range
Pressure ranges0…2.5 mbar · 0…4 mbar · 0…6 mbar · 0…10 mbar · 0…25 mmH2O · 0…40 mmH2O · 0…100 mmH2O · 0…1 kPa · 0…1.6 kPa · 0…2.5 kPa · 0…25 mbar · 0…40 mbar · 0…60 mbar · 0…100 mbar · 0…250 mmH2O · 0…400 mmH2O · 0…600 mmH2O · 0…1000 mmH2O · 0…4 kPa · 0…6 kPa · 0…10 kPa · 0…16 mbar · 0…60 mmH2O · 0…5 inH2O · 0…10 inH2O · 0…15 inH2O · 0…20 inH2O · -2.5…0 mbar · -4…0 mbar · -6…0 mbar · -10…0 mbar · -16…0 mbar · -25…0 mbar · -40…0 mbar · -60…0 mbar · -100…0 mbar · -10…6 mbar · -10…15 mbar · -10…30 mbar · -10…50 mbar · -15…10 mbar · -15…25 mbar · -20…5 mbar · -20…20 mbar · -20…40 mbar · -25…15 mbar · -25…75 mbar · -30…30 mbar · -40…20 mbar · -40…60 mbar · -50…10 mbar · -50…50 mbar · -60…40 mbar · -75…25 mbar · -80…20 mbar · -1…5 mbar · -2…4 mbar · -2…8 mbar · -3…3 mbar · -4…2 mbar · -4…6 mbar · -4…12 mbar · -5…1 mbar · -5…5 mbar · -6…10 mbar · -8…2 mbar · 0…25 inH2O · 0…30 inH2O · 0…40 inH2O · -8…8 mbar · 0…160 mmH2O
Accuracy
Accuracy class1.6, 1.0, 0.6
Accuracy standardEN 837-3
Process conditions
Process connection
M20 x 1.5G ½ B½ NPTG1/2B1/2NPT
Process temperature−40…+100 °C
Materials
Case materialStainless steel 1.4301 (304), Stainless steel 1.4571 (316 Ti)
Wetted parts materialStainless steel 1.4571 (316 Ti)
Sealing materialPTFE
Operating environment
Ambient temperature−20…+60 °C
IP ratingIP54
Weight1.6 kg
Certifications and approvals
Certifications
CRNUKCAEACMChSPACATEXEx UkrainePAC KazakhstanPAC UkrainePAC UzbekistanPAC ChinaCEEACEx
Explosion protection
ATEX II 2G h IIC T6 ... T1 Gb XATEX II 2D h IIIC T85°C ... T450°C Db XEAC ExATEXEACEx UkraineUKCAATEX directive Gas II 2G h IIC T6 ...T1 Gb XDust II 2D h IIC T85℃ ...T450℃ Db XEx Ukraine Hazardous areasPAC KazakhstanMChS KazakhstanPAC UkrainePAC UzbekistanPAC China
Additional details
Dial size100 mm
Datasheet languagesEN, DE
Tables from datasheet
Basic information
Standard
Diaphragm and capsule pressure gaugesEN 837-3
→For information on the 'Selection, installation, handling and operation of pressure gauges', see Technical information IN 00.05.
Nominal size (NS)■ Ø100 mm[4"] ■ Ø160 mm[6"]
WindowLaminated safety glass
CaseSafety level 'S1' per EN 837-1:With blow-out device
Material■ Stainless steel 1.4301 (304) ■ Stainless steel 1.4571 (316 Ti)
RingBayonet ring, stainless steel
MovementStainless steel
Measuring element
Type of measuring elementCapsule element
Materials (wetted)
Capsule elementStainless steel 1.4571 (316 Ti)
Measuring chamberStainless steel 1.4571 (316 Ti)
SealingPTFE
Process connectionStainless steel 1.4571 (316 Ti)
Accuracy specifications
Accuracy class■ 1.6 ■ 1.0 1) ■ 0.6 1)
Zero point settingSetting by means of adjustable pointer
Temperature errorOn deviation from the reference conditions at the measuring system: ≤ ±0.6 %per 10 °C [≤ ±0.6 %per 18 °F] of full scale value
Reference conditions
Ambient temperature+20 °C [68 °F]
mbar
0 ... 2,50 ... 25
0 ... 40 ... 40
0 ... 60 ... 60
0 ... 100 ... 100
0 ... 16-
View all (17)
mmH 2 O
0 ... 250 ... 250
0 ... 400 ... 400
0 ... 600 ... 600
0 ... 1000 ... 1,000
0 ... 160-
inH 2 O
0 ... 50 ... 25
0 ... 100 ... 30
0 ... 150 ... 40
0 ... 20-
kPa
0 ... 10 ... 4
0 ... 1,60 ... 6
0 ... 2,50 ... 10
mbar
-2.5 ... 0-8 ...+8
-4 ... 0-10 ...+6
-6 ... 0-10 ...+15
-10 ... 0-10 ...+30
-16 ... 0-10 ...+50
-25 ... 0-15 ...+10
-40 ... 0-15 ...+25
-60 ... 0-20 ...+5
-100 ... 0-20 ...+20
-1...+5-20 ...+40
-2 ...+4-25 ...+15
-2 ...+8-25 ...+75
-3 ...+3-30 ...+30
-4 ...+2-40 ...+20
-4 ...+6-40 ...+60
-4 ...+12-50 ...+10
-5 ...+1-50 ...+50
-5 ...+5-60 ...+40
-6 ...+10-75 ...+25
-8 ...+2-80 ...+20
Further details on: Scale ranges
Unit■ mbar ■ kPa ■ mmH 2 O ■ inH 2 O
Other units on request
Overload safety50 x full scale value 1) 2)
Vacuum resistance■ Without ■ 10 x full scale value 2) ■ 3 x full scale value 2)
Dial
Scale layout■ Single scale ■ Dual scale
Scale colourSingle scaleBlack
Dual scaleBlack/red
MaterialAluminium
Customer-specific versionOther scales, e.g. with red mark, circular arcs or circular sectors, on request →Alternatively, adhesive label set for red and green circular arcs; see data sheet AC 08.03
Instrument pointerAdjustable pointer, aluminium, black
Process connection
Standard■ EN 837 ■ ANSI / ASME B1.20.1
Size 1)
EN 837■ G½B ■ M20 x 1.5
ANSI / ASME B1.20.1½NPT
Materials (wetted)
Capsule elementStainless steel 1.4571 (316 Ti)
Measuring chamberStainless steel 1.4571 (316 Ti)
SealingPTFE
Process connectionStainless steel 1.4571 (316 Ti)
Operating conditions
Medium temperature range+100 °C [+212 °F] maximum
Ambient temperature range-20 ...+60 °C [-4 ...+140 °F]
Storage temperature range-40 ...+70 °C [-4 ... 140 °F]
Pressure limitation
SteadyFull scale value
Fluctuating0.9 x full scale value
Ingress protection per IEC/EN 60529IP54
LogoDescriptionRegion
-CRN Safety (e.g. electr.Canada
LogoDescriptionRegion
EU declaration of conformity ATEX directiveEuropean Union
UKCAUnited Kingdom
EAC Hazardous areasEurasian Economic Community
Ex Ukraine Hazardous areasUkraine
PAC Kazakhstan Metrology, measurement technologyKazakhstan
-MChS Permission for commissioningKazakhstan
-PAC Ukraine Metrology, measurement technologyUkraine
PAC Uzbekistan Metrology, measurement technologyUzbekistan
-PAC China Metrology, measurement technologyChina
Certificates
Certificates■ 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, indication accuracy) ■ 3.1 inspection certificate per EN 10204 (e.g. material proof for wetted metal parts, indication accuracy)
Recommended calibration interval1 year (dependent on conditions of use)
Process connection GDimensions in mm[in]Weight in kg [lb]
dabD1D2eh ± 1 [0.04]SW
G½B133 [5.24]15.5 [0.61]49.5 [1.95]101 [3.98]99 [3.90]17.5 [0.69]170 [6.69]22 [0.87]1.6 [3.53]
½NPT133 [5.24]15.5 [0.61]49.5 [1.95]101 [3.98]99 [3.90]17.5 [0.69]169 [6.65]22 [0.87]2.1 [4.63]
Process connection GDimensions in mm[in]Weight in kg [lb]
dabD1D2eh ± 1 [0.04]SW
G½B133 [5.24]15.5 [0.61]49.5 [1.95]161 [6.34]159 [6.26]17.5 [0.69]200 [7.87]22 [0.87]1.6 [3.53]
½NPT133 [5.24]15.5 [0.61]49.5 [1.95]161 [6.34]159 [6.26]17.5 [0.69]199 [7.83]22 [0.87]2.1 [4.63]
ModelDescriptionOrder number
910.33Adhesive label set for red and green circular arcs →See data sheet AC 08.03 NS 100 [4"]- 14238945
910.17Sealings →See data sheet AC 09.08On request
910.14Connection adapters for pressure measuring instruments →See data sheet AC 09.05On request
910.15Syphons →See data sheet AC 09.06On request
IV20, IV21Block-and-bleed valve →See data sheet AC 09.19On request
IBF2, IBF3Monoblock with flange connection →See data sheet AC 09.25On request
910.16Mounting parts for wall and pipe mounting Instrument mounting bracket and adapter piece →See data sheet AC 09.07On request