Bourdon tube pressure gauge, stainless steel
Description
This high-quality Bourdon tube pressure gauge has been designed specifically for the display of occasional overpressure loads. The instrument can withstand up to 4 times the full scale value for short periods, without damage.
The use of high-quality stainless steel materials and the robust design are geared to applications in the chemical and process engineering industries. Thus the instrument is suitable for liquid and gaseous media, also in aggressive environments.
Measuring ranges from 0 … 0.6 to 0 … 40 bar [0 ... 10 to 0 ... 600 psi] are available for a wide variety of applications.
For further approvals, see page 5
Bourdon tube pressure gauge, model 232.36, NS 100 [4 " ]
WIKA manufactures and qualifies the pressure gauge in accordance with the standards EN 837-1 and ASME B40.100. This safety version is made up of a non-splintering window, a solid baffle wall between measuring system and dial and a blow-out back. In the event of a failure, the operator is protected at the front side, as media or components can only be ejected via the back of the case.
The QR code on the dial allows instrument-specific information such as the serial number, the order number, certificates and other product data to be retrieved from the internet easily and in the long term.
Special features
- Overpressure range is indicated completely on scale
- Safety version with solid baffle wall (Solidfront) designed in compliance with the requirements of EN 837-1 and ASME B40.100
- With case filling (model 233.36) for applications with high dynamic pressure loads and vibrations
- Measuring ranges from 0 … 0.6 bis 0 … 40 bar [0 ... 10 to 0 ...600 psi]
- QR code on dial links to instrument-specific information
Build a 23X.36 for your task
The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.
- Case fillingwith
- Nominal size100 mm
- Unit of outer Scalebar
- Measuring rangegauge pressure range
- Scale range0...0.6 bar overpressure safe to 2.5 bar
- 2nd Scale or Special Scalewithout
- Process connection—
- Connector locationlower mount
- Mounting flange/bracketwithout
- Windowlaminated safety glass
- Restrictorwithout
- Pointerstandard pointer
- Set / drag pointerwithout
- Special design featureswithout
- Explosion protection—
- Ignition protection type—
- Zone—
Finish your configuration
Select every option to submit the request.
| Model | 232.36 |
| Product family | 232 |
| Subcategory | Mechanical pressure gauge |
| Pressure ranges | 0…0.6 bar · 0…1 bar · 0…1.6 bar · 0…2.5 bar · 0…4 bar · 0…6 bar · 0…10 bar · 0…16 bar · 0…25 bar · 0…40 bar · -1…0 bar · -1…0.6 bar · -1…1.5 bar · -1…3 bar · -1…5 bar · -1…9 bar · -1…15 bar · -1…24 bar · 0…10 psi · 0…15 psi · 0…60 psi · 0…150 psi · 0…250 psi · 0…400 psi · 0…600 psi · 0…0.06 MPa · 0…0.1 MPa · 0…0.16 MPa · 0…0.25 MPa · 0…0.4 MPa · 0…0.6 MPa · 0…1 MPa · 0…1.6 MPa · 0…2.5 MPa · 0…4 MPa · 0…60 kPa · 0…100 kPa · 0…160 kPa · 0…250 kPa · 0…400 kPa · 0…600 kPa · 0…1000 kPa · 0…1600 kPa · 0…2500 kPa · 0…4000 kPa · -100…0 kPa · -100…60 kPa · -100…150 kPa · -100…300 kPa · -100…400 kPa · -100…900 kPa · -100…1500 kPa · -100…2400 kPa · -30…0 inHg · -30…15 inHg · -30…30 inHg · -30…60 inHg · -30…100 inHg · -30…160 inHg · -30…200 inHg · -30…300 inHg · -0.1…0 MPa · -0.1…0.06 MPa · -0.1…0.15 MPa · -0.1…0.3 MPa · -0.1…0.5 MPa · -0.1…0.9 MPa · -0.1…1.5 MPa · -0.1…2.4 MPa |
| Accuracy class | 1.0 |
| Accuracy standard | EN 837-1 |
| Process connection | M12 x 1.5M20 x 1.5G ½ BR ½½ NPTG ½ B, male threadM12 x 1.5, male threadM20 x 1.5, male threadR ½, male thread½ NPT, male threadG 1/2 BR 1/21/2 NPT |
| Process temperature | −40…+200 °C |
| Case material | Stainless steel 1.4301 (304), Stainless steel 1.4571 (316 Ti) |
| Wetted parts material | Stainless steel 1.4404 (316L) |
| Ambient temperature | −40…+60 °C |
| IP rating | IP65/IP66 |
| Weight | 0.65 kg |
| Certifications | UKCACECRNATEXEACPAC UkrainePAC UzbekistanPAC ChinaMChSPED |
| Explosion protection | II 2G Ex h IIC T6 ... T1 Gb XII 2D Ex h IIIC T85°C ... T450°C Db XATEX directive Ex h Gas II 2G Ex h IIC T6 ...T1 Gb XATEX directive Dust II 2D Ex h IIIC T85°C ...T450°C Db XUKCA Equipment and protective systems in explosive atmospheresEACEx |
| Dial size | 100 mm |
| Datasheet languages | EN, DE |
| Measuring range | Overload safety |
|---|---|
| bar | |
| 0 ... 0.6 | 2.5 |
| 0 ... 1 | 4 |
| 0 ... 1.6 | 6 |
| 0 ... 2.5 | 10 |
| 0 ... 4 | 16 |
| 0 ... 6 | 25 |
| 0 ... 10 | 40 |
| 0 ... 16 | 60 |
| 0 ... 25 | 80 |
| 0 ... 40 | 100 |
| Measuring range | Overload safety |
|---|---|
| psi | |
| 0 ... 10 | 35 |
| 0 ... 15 | 60 |
| 0 ... 60 | 230 |
| 0 ... 150 | 580 |
| 0 ... 250 | 930 |
| 0 ... 400 | 1,280 |
| 0 ... 600 | 1,500 |
| Measuring range | Overload safety |
|---|---|
| bar | |
| -1 ... 0 | 3 |
| -1 ... +0.6 | 3 |
| -1 ... +1.5 | 6 |
| -1 ...+3 | 16 |
| -1 ...+5 | 25 |
| -1 ...+9 | 40 |
| -1 ...+15 | 60 |
| -1 ...+24 | 80 |
| Measuring range | Overload safety |
|---|---|
| psi | |
| -30 inHg ... 0 | 45 |
| -30 inHg ...+15 | 45 |
| -30 inHg ...+30 | 100 |
| -30 inHg ...+60 | 250 |
| -30 inHg ...+100 | 400 |
| -30 inHg ...+160 | 600 |
| -30 inHg ...+200 | 800 |
| -30 inHg ...+300 | 1,000 |
View all (17)
| Measuring range | Overload safety |
|---|---|
| kPa | |
| 0 ... 60 | 250 |
| 0 ... 100 | 400 |
| 0 ... 160 | 600 |
| 0 ... 250 | 1,000 |
| 0 ... 400 | 1,600 |
| 0 ... 600 | 2,500 |
| 0 ... 1,000 | 4,000 |
| 0 ... 1,600 | 6,000 |
| 0 ... 2,500 | 8,000 |
| 0 ... 4,000 | 10,000 |
| Measuring range | Overload safety |
|---|---|
| MPa | |
| 0 ... 0.06 | 0.25 |
| 0 ... 0.1 | 0.4 |
| 0 ... 0.16 | 0.6 |
| 0 ... 0.25 | 1 |
| 0 ... 0.4 | 1.6 |
| 0 ... 0.6 | 2.5 |
| 0 ... 1 | 4 |
| 0 ... 1.6 | 6 |
| 0 ... 2.5 | 8 |
| 0 ... 4.0 | 10 |
| Measuring range | Overload safety |
|---|---|
| kPa | |
| -100 ... 0 | 300 |
| -100 ...+60 | 300 |
| -100 ...+150 | 600 |
| -100 ...+300 | 1,500 |
| -100 ...+400 | 2,400 |
| -100 ...+900 | 4,000 |
| -100 ... +1,500 | 6,000 |
| -100 ... +2,400 | 8,000 |
| Measuring range | Overload safety |
|---|---|
| MPa | |
| -0.1 ... 0 | 0.3 |
| -0.1 ... +0.06 | 0.3 |
| -0.1 ... +0.15 | 0.6 |
| -0.1 ... +0.3 | 1.5 |
| -0.1 ... +0.5 | 2.5 |
| -0.1 ... +0.9 | 4 |
| -0.1 ... +1.5 | 6 |
| -0.1 ... +2.4 | 8 |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity Pressure equipment directive PS > 200 bar, module A, pressure accessory | European Union | |
| UKCA Pressure equipment (safety) regulations | United Kingdom | |
| - | CRN Safety (e.g. electr. safety, overpressure, ...) For full scale value ≤ 1,000 bar | Canada |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity ATEX directive Hazardous areas - Ex h Gas II 2G Ex h IIC T6 ...T1 Gb X Dust II 2D Ex h IIIC T85°C ...T450°C Db X | European Union | |
| UKCA Equipment and protective systems intended for use in potentially explosive atmospheres regulations | United Kingdom | |
| EAC Hazardous areas | Eurasian Economic Community | |
| Ex Ukraine Hazardous areas | Ukraine | |
| PAC Kazakhstan Metrology, measurement technology | Kazakhstan | |
| - | MChS Permission for commissioning | Kazakhstan |
| - | PAC Ukraine Metrology, measurement technology | Ukraine |
| PAC Uzbekistan Metrology, measurement technology | Uzbekistan | |
| - | PAC China Metrology, measurement technology | China |
| Logo | Description |
|---|---|
| - | Pressure equipment directive (PED) for maximum allowable pressure PS ≤ 200 bar |
| - | Suitability of wetted materials for drinking water in accordance with the European 4MS initiative |
| - | Suitability of wetted materials for hydrogen |
| Certificates | ■ 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, indication accuracy) ■ 3.1 inspection certificate per EN 10204 (e.g. material proof for wetted metal parts, indication accuracy) ■ PCA calibration certificate, traceable and accredited in accordance with ISO/IEC 17025 ■ Calibration certificate by a national accreditation body, traceable and accredited in accordance with ISO/IEC 17025 on request |
|---|---|
| Recommended calibration interval | 1 year (dependent on conditions of use) |
| NS | G | Dimensions in mm[in] | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| h ±1 [0.04] | a | b | D1 | D2 | i | j | k | SW | ||
| 100 [4"] | G½B | 87 [3.43] | 25 [0.98] | 59.5 [2.34] | 100 [3.94] | 100 [3.94] | 6 [0.24] | 24 [0.94] | 15 [0.59] | 22 [0.87] |
| M12 x 1.5 | 80 [3.15] | |||||||||
| M20 x 1.5 | 87 [3.43] | |||||||||
| 160 [6"] | G½B | 118 [4.65] | 27 [1.06] 1) | 65 [2.56] 2) | 159 [6.26] | 159 [6.26] | 6 [0.24] | 18.5 [0.73] | 15 [0.59] | 22 [0.87] |
| M12 x 1.5 | 111 [4.37] | |||||||||
| M20 x 1.5 | 118 [4.65] |
| NS | G | Dimensions in mm[in] | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| h ±1 [0.04] a | b | D1 | D2 | i | j | k | SW | |||
| 100 [4"] | R½ | 86 [3.39] | 25 [0.98] | 59.5 [2.34] | 100 [3.94] | 100 [3.94] | 6 [0.24] | 24 [0.94] | 15 [0.59] | 22 [0.87] |
| 160 [6"] | R½ | 117 [4.61] | 27 [1.06] | 65 [2.56] | 159 [6.26] | 159 [6.26] | 6 [0.24] | 18.5 [0.73] | 15 [0.59] | 22 [0.87] |
| NS | G | Dimensions in mm[in] | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| h ±1 [0.04] a | b | D1 | D2 | i | j | k | SW | |||
| 100 [4"] | ½NPT | 86 [3.39] | 25 [0.98] | 59.5 [2.34] | 100 [3.94] | 100 [3.94] | 6 [0.24] | 24 [0.94] | 15 [0.59] | 22 [0.87] |
| 160 [6"] | ½NPT | 117 [4.61] | 27 [1.06] | 65 [2.56] | 159 [6.26] | 159 [6.26] | 6 [0.24] | 18.5 [0.73] | 15 [0.59] | 22 [0.87] |
| NS | Weight | |
|---|---|---|
| Model 232.36 | Model 233.36 | |
| 100 [4"] | approx. 0.65 kg [1.43 lb] | approx. 1.08 kg [2.38 lb] |
| 160 [6"] | approx. 1.30 kg [2.87 lb] | approx. 2.34 kg [4.94 lb] |
| Model | Description | |
|---|---|---|
| 910.17 | Sealings →See data sheet AC 09.08 | |
| 910.15 | Syphons →See data sheet AC 09.06 | |
| 910.13 | Overpressure protector →See data sheet AC 09.04 | |
| IV1 | Needle valve and multiport valve →See data sheet AC 09.22 | |
| IV2 | Block-and-bleed valve →See data sheet AC 09.19 | |
| IVM | Monoflange, process and instrument version →See data sheet AC 09.17 | |
| BV | Ball valve, process and instrument version →See data sheet AC 09.28 | |
| IBF2, IBF3 | Monoblock with flange connection →See data sheet AC 09.25 |
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →21 standard articles of family 232
If you know the code — pick directly. If not — use the configurator in mode “01”.