AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
230.15 1
230.15
On order
WIKA · Pressure measurement · Family 230

Bourdon tube pressure gauge with switch contacts

For UHP (ultra high purity) applications, with reed contact model 851
Range
0…6000 psi
Output
SPDT
Accuracy
±2.5 % of measuring span
Protection
IP20
RoHSCEEMCPressure Equipment DirectiveLow Voltage DirectiveATEXIECExFMEx ic IIC T6 GcII 3G Ex ic IIC T6 Gc
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The model 230.15 is a bourdon tube pressure gauge with up to 2 Reed contacts model 851. It was created for high purity applications that require discrete monitoring outputs for globally installed systems and life safety applications.

The switch point can easily be adjusted by removing the window and putting the mark pointer on the desired value on the dial's circumference.

Fig. left: Model 230.15 with 1 contact model 851.3 Fig. right: Model 230.15 with 2 contacts model 851.33

The pressure gauge is helium leak tested and the internals are electropolished to optimally meet purity standards. The instrument complies with SEMATECH and SEMI standards to optimally ensure the quality your applications demand.

With such UHP characteristics, the instrument is suitable for the semiconductor and flat panel industries, various gas distribution systems, as well as medical gas applications.

Special features

  • Up to 2 Reed contacts, SPDT
  • Switch points adjustable on site
  • Wetted parts from stainless steel 316L and face seal process connections
  • Electropolished internals and case, internal surface finish up to Ra < 0.25 μm [Ra < 10 μin]
  • Scale ranges from -30 inHg ... 45 psi to 0 ... 6,000 psi
Identification
Model230.15
Product family230
SubcategoryWith switch contacts
Measuring range
Pressure ranges0…300 psi · 0…400 psi · 0…500 psi · 0…600 psi · 0…800 psi · 0…1000 psi · 0…1500 psi · 0…2000 psi · 0…3000 psi · 0…4000 psi · 0…5000 psi · 0…6000 psi · 0…60 psi · 0…100 psi · 0…150 psi · 0…200 psi · 0…250 psi · -30…45 inHg · 0…160 psi
Accuracy
Accuracy class±2.5 % of measuring span
Accuracy standardASME B40.100
Process conditions
Process connection
¼ fixed male¼ weld stub¼ NPT male¼ swivel male or female face sealVCR-compatible face seal9/16-18 UNF swivel male or female face seal¼ swivel male face seal¼ swivel female face seal9/16-18 UNF swivel male9/16-18 UNF swivel female
Process temperature≤ +100 °C
Electrical characteristics
Output signalSPDT
Electrical connectionCable gland M8 x 1.25, 3 m cable, flying leads
Switching function1 x SPDT (model 851.3), 2 x SPDT (model 851.33)
Switching contacts2
Materials
Case materialStainless steel 304
Wetted parts materialStainless steel 316L
Operating environment
Ambient temperature−40…+40 °C
IP ratingIP20
Certifications and approvals
Certifications
RoHSCEEMCPressure Equipment DirectiveLow Voltage DirectiveATEXIECExFM
Explosion protection
Ex ic IIC T6 GcAEx/Ex ic IIC GC; Class I, Division 2, Groups A, B, C, DII 3G Ex ic IIC T6 Gc
Additional details
Dial size50 mm
Datasheet languagesEN
Tables from datasheet
Mechanical Data, model 230.15
DesignBourdon tube pressure gauge per ASME B40.100
Nominal size (NS)2.0" [50 mm]
Accuracy classIndication: Switch:±2,5 %of measuring span according to ASME B40.100 (Grade A) ±5 %of measuring span at switch point
Scale range■ -30 inHg ■ -30 inHg ■ -30 inHg ■ -30 inHg ■ -30 inHg ■ -30 inHg...+45 psi ...+60 psi ...+100 psi ...+160 psi ...+200 psi ...+300 psi■ 0 ... 300 psi ■ 0 ... 400 psi ■ 0 ... 500 psi ■ 0 ... 600 psi ■ 0 ... 800 psi ■ 0 ... 1,000 psi0 ... 1,500 psi 0 ... 2,000 psi 0 ... 3,000 psi 0 ... 4,000 psi 0 ... 5,000 psi 0 ... 6,000 psi 1)
Pressure limitationSteady: Full scale value Fluctuating: ¾xfull scale value Short time: 2/3 x full scale value
Permissible temperature range Medium Ambient≤ 212 °F [≤ 100 °C] -40 ...+104 °F [-40 ...+40 °C]
Temperature effectWhen the temperature at the measuring system deviates from the reference temperature +68 °F [+20 °C]: max. ±0.4 %/10 K of full scale value
Ingress protectionIP20 per IEC/EN 60529
Process connection Material Connection location ThreadVCR-compatible face seal fittings Face seal nut: Stainless steel 316, Option: Gall resistant (Nitronic ® 60) Face seal gland: Stainless steel 316L Lower mount (LM) or center back mount (CBM) ¼swivel male or female face seal, ¼fixed male, ¼weld stub, 9/16-18 UNF swivel male or female face seal Option:¼NPTmale
Pressure elementStainless steel 316L C-type or helical type
Material of wetted partsStainless steel 316L, electropolished
Surface roughness of wetted partsRa ≤ 0.25 μm [10 μin] For process connection ¼NPTmale:Ra ≤ 0.5 μm [20 μin]
Level of cleanlinessClean for semiconductor applications in accordance with SEMI / SEMATEC. Cleaned and packaged in class 100/10 cleanroom Packaged in two bags Purged with nitrogen Protective cap over threaded connection
MovementStainless steel
DialAluminium, white, black lettering with pointer stop pin
CaseStainless steel 304, electropolished
Pointer
WindowAluminium, black Polycarbonate, Screw-fitted on case (twist lock)
Electrical data, contact model 851
DesignReed switch contact
Switching functionContact model 851.3: 1 x SPDT (change-over contact);SP1 Contact model 851.33: 2 x SPDT (change-over contact);SP1 and SP2
Switch point settingThe instrument should be disconnected from the monitoring device and the window unscrewed. The switch is set via the mark pointer on the dial&#x27;s circumference.The set value of the switch point is adjustable up to 80% of the scale range,15% from low end and 5% from high end of scale.
Electrical rating Switching voltage Switching current Switching power≤ AC 24V / DC 24V ≤ 0.5 A ≤ 10VA/W
Electrical connectionCable gland M8 x 1.25, with 3 m( cable long (10 ft), wire cross section 0.14 mm² (26 AWG) with flying leads
LogoDescriptionCountry
EU declaration of conformity ■ EMCdirective ■ Pressure equipment directive ■ Low voltage directive ■ RoHS directive ■ ATEX directive (option) Hazardous areas - Ex ic Gas [II 3G Ex ic IIC T6 Gc]European Union
IECEx (option) Hazardous areas - Ex ic Gas [Ex ic IIC T6 Gc]International
FM (option) Hazardous areas AEx/Ex ic IIC GC;Class I, Division 2, Groups A, B, C, DUSA and Canada