WIKA · Pressure measurement · Family 216

Pressure gauge for scuba diving (finimeter)

Pressure gauge for scuba diving (finimeter) with high impact resistance and phosphorescent dial for readability in poor lighting conditions.
Range
0…600 bar
Accuracy
Indication accuracy per EN 250
DIN EN 250DIN EN 13949DIN EN 14143CE
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

These pressure gauges meet the highest standards in terms of quality and reliability in scuba diving applications. The compact finimeter is a component of diving equipment for cylinder pressure measurement.

Due to the fine scale graduation, the pressure is very well readable. Through its long fade-out time, the phosphorescent dial also makes the readability easier in poor lighting conditions.

For the diver's safety, a window of shatterproof polycarbonate is used.

Fig. left: Model 216.06.050

Fig. right: Model 216.40.050

Seite 1 von 5

Special features

  • Full compliance with DIN EN 250, DIN EN 13949, DIN EN 14143
  • Model 216.06.050 suitable for diving depths of up to 500 m [1,640 ft]
  • Compact design
  • High impact resistance of the window from polycarbonate
  • Phosphorescent dial
Identification
Model216.06.050
Product family216
SubcategoryMechanical pressure gauge
Measuring range
Pressure ranges0…400 bar · 0…5800 psi · 0…600 bar
Accuracy
Accuracy classIndication accuracy per EN 250
Accuracy standardEN 250
Process conditions
Process connection
7/16-20 UNF, male threadG ⅛ B, male threadM12 x 1.5, male threadG 1/8 B, male thread
Materials
Case materialBrass, nickel-plated
Wetted parts materialCopper alloy, Stainless steel
Operating environment
Ambient temperature+20…+20 °C
Weight0.11 kg
Certifications and approvals
Certifications
DIN EN 250DIN EN 13949DIN EN 14143CE
Additional details
Dial size50 mm
Datasheet languagesDE, EN
Tables from datasheet
Basic information
Standard■ DIN EN 250, respiratory equipment for use with compressed air ■ DIN EN 14143, respiratory equipment, self-contained re-breathing apparatus ■ DIN EN 13949, respiratory equipment for use with compressed Nitrox and oxygen
Diving depth
Model 216.06.050≤ 100 m[328 ft]
Model 216.40.050≤ 500 m[1,640 ft]
Nominal size (NS)Ø50 mm[2"]
Connection locationLower mount (radial)
WindowPolycarbonate
CaseBrass, nickel-plated
MovementCopper alloy
Measuring element
Type of measuring elementBourdon tube, helical type
Material
Model 216.06.050Copper alloy
Model 216.40.050Stainless steel
Accuracy specifications
Accuracy classIndication accuracy per EN 250
Temperature errorOn deviation from the reference conditions at the measuring system: ≤ ±0.4 %per 10 °C [≤ ±0.4 %per 18 °F] of full scale value
Reference conditions
Ambient temperature+20 °C [68 °F]
Scale range
Scale range
Model 216.06.050Maximum 0 ... 400 bar [5,800 psi]
Model 216.40.050Maximum 0 ... 600 bar [8,700 psi]
Dial
Scale colourBlack
MaterialModel 216.06.050Plastic
Model 216.40.050Aluminium
VersionPhosphorescent background with long fade-out time
Other scales or customer-specific dials, e.g. with red mark, circular arcs or circular sectors, on request
Pointer
Instrument pointerModel 216.06.050Aluminium, black
Model 216.40.050Copper alloy, black
Mark pointer/drag pointer■ Without ■ Red mark pointer on dial,fixed
Pointer stop pinAt zero point
View all (6)
GDimensions in mm[in]
Dab ±0.5 [0.02]eh ±1 [0.04]S3SW
G⅛B49.5 [1.95]6 [0.24]22 [0.87]12.5 [0.49]41 [1.61]12.5 [0.49]12 [0.47]
7/16-20 UNF49.5 [1.95]6 [0.24]22 [0.87]12.5 [0.49]41 [1.61]7.5 [0.30]12 [0.47]
GDimensions in mm[in]
D1D2ab ±0.5 [0.02]h ±1 [0.04]h1 ±0.5 [0.02]S3SW
G⅛B51 [2.01]48 [1.89]10.5 [1.17]40 [1.57]47 [1.85]32 [1.26]10 [0.39]14 [0.55]
M12 x 1.551 [2.01]48 [1.89]10.5 [1.17]40 [1.57]50 [1.97]32 [1.26]13 [0.51]14 [0.55]