WIKA · Pressure measurement · Family 101
Bourdon tube pressure gauge, copper alloy
With capillary, NS 27 [1"] and 40 [1 ½"]
Range
0…6 bar
Accuracy
Class 2.5
Protection
IP41
EN 837-1
Price
On request
Depends on configuration
Description
The model 101.00 is a Bourdon tube pressure gauge with a capillary. This instrument is based on the proven Bourdon tube measuring system. The plastic case is available in nominal sizes of 27 mm [1"] and 40 mm [1 ½"].
Special features
- Process connection: G ¼ B or plug connection
- Scale range: 0…4 bar [0 ... 60 psi] or 0… 6 bar [0 ... 100 psi]
- Very simple to install (snap-in mounting)
- No bending or coiling of plastic capillary necessary
- Suitability of plastic capillary confirmed in long-term tests under characteristic application conditions
Identification
| Model | 101.00 |
| Product family | 101 |
| Subcategory | Bourdon tube pressure gauge with capillary |
Measuring range
| Pressure ranges | 0…4 bar · 0…6 bar · 0…400 kPa · 0…600 kPa · 0…0.4 MPa · 0…0.6 MPa · 0…60 psi · 0…100 psi · 0…4 kg/cm2 · 0…6 kg/cm2 |
Accuracy
| Accuracy class | Class 2.5 |
| Accuracy standard | EN 837-1 |
Process conditions
| Process connection | G 1/4 BM14 x 1Plug connection |
| Process temperature | −20…+60 °C |
Materials
| Case material | Plastic |
| Wetted parts material | Copper alloy |
| Sealing material | Plastic, PTFE |
Operating environment
| Ambient temperature | −20…+60 °C |
| IP rating | IP41 |
| Weight | 0.05 kg |
Certifications and approvals
| Certifications | EN 837-1 |
Additional details
| Dial size | 40 mm |
Tables from datasheet
Operating conditions
| Medium temperature | -20 ...+60 °C [-4 ...+140 °F] |
|---|---|
| Ambient temperature | -20 ...+60 °C [-4 ...+140 °F] |
| Pressure limitation | |
| Steady | 3/4 x full scale value |
| Fluctuating | 2/3 x full scale value |
| Short time | Full scale value |
| Ingress protection per IEC/EN 60529 | IP41 |
| Logo | Description | Region |
|---|---|---|
| PAC Kazakhstan Metrology, measurement technology | Kazakhstan | |
| - | PAC Ukraine Metrology, measurement technology | Ukraine |
| PAC Uzbekistan Metrology, measurement technology | Uzbekistan |
Certificates
| Certificates | 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, indication accuracy) |
|---|---|
| Recommended calibration interval | 1 year (dependent on conditions of use) |
Industry
Heating / Utilities
Heating technology
Couldn't find the answer in the documentation? An engineer will reply within a business day.