Fault · SINAMICS G130, G150, S120, S150

F40004Fault at DRIVE-CLiQ socket X104

What it means

F40004 reports that a fault has occurred at the drive object connected at DRIVE-CLiQ socket X104. The code acts as a first-fault message: the drive stores the first fault that has occurred for this drive object as the fault value, which you read in r0949 as a decimal number.

Why it appears

  • A fault has occurred at the drive object connected at DRIVE-CLiQ socket X104.

What to check

  1. Evaluate the fault buffer of the drive object specified by the message.
  2. Read the fault value in r0949 as a decimal number; it names the first fault that has occurred for this drive object, and the remedy for that fault applies.

Reading the message value

  • The drive stores the fault value in r0949; interpret it as a decimal number.
  • The manual decodes the value only as the first fault that has occurred for this drive object — no bit-by-bit decoding is given.

Parameters the manual names

  • r0949 — fault value: read it as a decimal number to identify the first fault that has occurred for the drive object at X104.

Acknowledging and restarting

Acknowledge the fault immediately. The fault itself triggers no automatic response from the drive; it points to the first fault of the drive object at X104, which you find by evaluating that object's fault buffer.

The same on every family

Every manual that describes F40004 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
G130, G150NONEIMMEDIATELYGeneral drive fault (19)NoneSINAMICS G130, G150 List Manual · p. 1922
S120, S150NONEIMMEDIATELYGeneral drive fault (19)NoneSINAMICS S120, S150 List Manual · p. 3279

The drives this code lives on

F40004 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does SINAMICS fault F40004 mean?

It reports that a fault has occurred at the drive object connected at DRIVE-CLiQ socket X104. The value in r0949, read as a decimal number, is the first fault that has occurred for this drive object.

How do I clear fault F40004?

Evaluate the fault buffer of the drive object specified by the message — r0949 shows which fault occurred first, and that fault's remedy applies. The fault must be acknowledged immediately.

Where is the fault value of F40004 stored?

In r0949, interpreted as a decimal number. It contains the first fault that has occurred for the drive object at X104.