Alarm · SINAMICS G130, G150, S120, S150

A06901Braking Module: Pre-alarm I2t shutdown

What it means

Alarm A06901 is raised when a Braking Module in "Booksize" format reports its "Pre-alarm I2t shutdown" through terminal X21.3. The signal reaches the drive only because X21.3 is wired to a digital input of the system and this input is interconnected at binector input p3865[0...7]; the alarm comes out of that interconnection. The manuals state that the function is not supported for the "chassis" format, so the pre-alarm path via p3865[0...7] exists for Booksize units only.

Why it appears

  • A Braking Module of "Booksize" format has output its pre-alarm of the I2t shutdown at terminal X21.3.
  • The signal arrives in the drive because terminal X21.3 is wired to a digital input of the system and interconnected there using binector input p3865[0...7].
  • Braking Modules of "chassis" format do not support this function, so the alarm concerns only the Booksize design.

What to check

  1. Reduce the number of braking operations.
  2. Check binector input p3865[0...7] and the wiring that runs from terminal X21.3 of the Braking Module concerned.

Parameters the manual names

  • p3865 (BI: Braking Module pre-alarm I2t shutdown / BM pre-A I2t shutd) — the binector input at which the signal wired from terminal X21.3 must be interconnected; verify this interconnection when A06901 appears.

Acknowledging and restarting

No acknowledgement is needed for this alarm. It goes away once the cause is removed: fewer braking operations, and the interconnection at p3865[0...7] together with the wiring from terminal X21.3 found in order.

The same on every family

Every manual that describes A06901 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONENONEBraking Module faulted (14)NoneSINAMICS S120, S150 List Manual · p. 2773
G130, G150NONENONEBraking Module faulted (14)NoneSINAMICS G130, G150 List Manual · p. 1531

The drives this code lives on

A06901 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does alarm A06901 mean on a SINAMICS S120 or G130?

A Booksize-format Braking Module is signalling its pre-alarm of the I2t shutdown at terminal X21.3, and that signal is interconnected at binector input p3865[0...7]. The function is not supported for the chassis format.

How do I clear A06901?

Reduce the number of braking operations and check binector input p3865[0...7] along with the wiring from terminal X21.3 of the Braking Module. No acknowledgement action is required.

Which parameter belongs to A06901?

p3865, the binector input for the Braking Module pre-alarm I2t shutdown; the signal from terminal X21.3 must be interconnected there.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the A06xxx group · SINAMICS manuals · Siemens manuals