AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
TXS 1
TXS
On order
WIKA · Temperature measurement · Family Process Mini Series

Mini temperature switch

Stainless steel switch enclosure
Range
-15…250 °C
Accuracy
≤ 1 % of span
Protection
IP66
CEEACRoHSREACHEx ia I MaEx ia IIIC T85/T135 DaEx ia IIC T6/T4 GaEx ia IIC T6/T4
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

These high-quality temperature switches have been developed especially for safety-critical applications. The high quality of the products and manufacturing in accordance with ISO 9001 ensure reliable monitoring of your plant. In production, the switches are traced by quality assurance software at every step and subsequently are 100 % tested.

In order to ensure as flexible operation as possible, the temperature switches are fitted with micro switches, which enable the switching of an electrical load of up to AC 250 V, 5 A directly. For lower switching power ratings, such as for PLC applications, micro switches with gold-plated contacts can be selected as an option.

Special features

  • Case from AISI 316 (1.4401)
  • Ingress protection IP 66, NEMA 4
  • Ambient temperature -40 ... +85 °C
  • 1 switch point, SPDT, up to 5 A / AC 250 V
  • Directly connected or via capillary (up to 10 m capillary)
Identification
ModelTXS
Product familyProcess Mini Series
SubcategoryTemperature switch
Measuring range
Temperature ranges−15…+20 °C · +5…+70 °C · +55…+140 °C · +130…+190 °C · +180…+250 °C
Accuracy
Accuracy class≤ 1 % of span
Process conditions
Process connection
½ NPT male¾ NPT maleG ½ A maleG ¾ A male
Process temperature−40…+330 °C
Electrical characteristics
Electrical connectionConnection cable, 1.5 m, 0.5 mm², silicone insulation
Materials
Probe materialStainless steel 316, AISI 316
Operating environment
Ambient temperature−40…+85 °C
IP ratingIP66
Weight0.8 kg
Certifications and approvals
Certifications
CEEACRoHSREACH
Explosion protection
Ex ia I MaEx ia IIIC T85/T135 DaEx ia IIC T6/T4 GaEx ia IIC T6/T4
Additional details
Sensor typebimetal
Probe length125 mm
Probe diameter9.5 mm
ThermowellNo
Datasheet languagesEN, DE
Tables from datasheet
Measuring rangeSetting range depending on the switching direction in °CWorking rangeProof temperatureMax. dead bandSAMA class
in °CRisingFallingin °Cin °Cin °C
-15 ... +20-10 ...+20-15 ...+15-40 ...+5070≤ 5IIC
5 ... 7011 ... 705 ... 64-40 ...+95120≤ 6IIC
55 ... 14061 ...14055 ... 134-40 ...+160190≤ 6IIC
130 ... 190142 ... 190130 ... 178-40 ...+215230≤ 12IIA
180 ... 250192 ... 250180 ... 238-40 ...+300330≤ 12IIA
Maximum values
Voltage U iDC 30V
Current l i100mA
Power P i0.75W
Internal capacitance C i0 μF
Internal inductance L i0mH
Electrical rating (resistive load)Suitable for Ex ia option
ACDC
250 V, 5 A24 V, 5 AYes
250 V, 0.5 A24 V, 1 AYes
LogoDescriptionCountry
EC declaration of conformity ■ Low voltage directive ■ ATEX 1) (option) IM1 II1GDEuropean Community
IECEx 1) per IEC 60079-0, IEC 60079-11, IEC 60079-26 (option) Ex ia I Ma Ex ia IIC T6/T4 2) Ga Ex ia IIIC T85/T135 2) DaIECEx member states
EAC (option) Hazardous areas (option)Eurasian Economic Community
KOSHA (option) Hazardous areasSouth Korea