WIKA · Temperature measurement · Family TR53
Bayonet resistance thermometer
Bayonet resistance thermometer for applications in plastics processing, injection moulding, engines, bearings, pipelines and vessels, with options for explosion protection and various sensor configurations.
Range
-196…600 °C
Protection
IP65
RoHSEACGOSTMTSCHSBelGIMUkrSEPROUzstandardKazInMetrINMETRONEPSIPESOKCs - KOSHADNOP - MakNIICEATEXIECExKCs-KOSHADNOP-MakNIIKazinMetr[Ex ia IIC T1 ... T6 Ga][Ex ia IIIC T125 ... T65 °C Da][Ex ib IIC T3 ... T6 Ga/Gb][Ex ib IIC T3 ... T6 Gb][Ex ia IIC T3 ~ T6][Ex ia/ib IIC T3 ~ T6][II 1G Ex ia IIC T1 ... T6 Ga][II 2G Ex ia IIC T1 ... T6 Gb][II 3G Ex nA IIC T1 ... T6 Gc X][Ex ia IIC T1 ... T6 Ga/Gb][Ex ia IIC T1 ... T6 Gb][Ex ia IIIC T125 ... T65 °C Db][0 Ex ia IIC T3/T4/T5/T6][1 Ex ib IIC T3/T4/T5/T6][Ex nA IIC T6 ... T1][DIP A22 Ta 80 ... 440 °C][Ex ia IIC T3 ... T6 Ga][Ex ib IIIC T125 ... T65 °C Db][Ex ib IIC T3 ~ T6][Ex ia IIC T4 ... T6][Ex ib IIC T4 ... T6][II 1G Ex ia IIC T1 ...T6 Ga][II 2G Ex ia IIC T1 ...T6 Gb][II 3G Ex nA IIC T1 ...T6 Gc X][Ex ia IIC T3 ...T6 Ga][Ex ib IIC T3 ...T6 Ga/Gb][Ex ib IIC T3 ...T6 Gb][Ex ia IIIC T125 ...T65 °C Da][Ex ia IIC T4 ...T6][Ex ib IIC T4 ...T6]II 1G Ex ia IIC T1...T6 GaII 1/2G Ex ia IIC T1...T6 Ga/GbII 2G Ex ia IIC T1...T6 GbII 1D Ex ia IIC T125...T65℃ DaII 2D Ex ia IIC T125...T65℃ DbII 3G Ex nA IIC T1...T6 Gc X0 Ex ia IIC T3/T4/T5/T61 Ex ib IIC T3/T4/T5/T6Ex nA IIC T6...T1DIP A22 Ta 80...440 °CEx ia IIC T3...T6 GaEx ib IIC T3...T6 Ga/GbEx ib IIC T3...T6 GbEx ia IIC T125...T65 °C DaEx ib IIC T125...T65 °C Da/DbEx ib IIC T125...T65 °C DbEx ia IIC T3 ~T6Ex ia/lib IIC T3 ~T6Ex ib IIC T3 ~T6Ex ia IIC T4...T6Ex ib IIC T4...T6II 2D Ex ib IIC T125...T65 °C Db
Price
On request
Depends on configuration
Special features
- Sensor ranges up to max. 400 °C [752 °F]
- Single and dual resistance thermometers
- Good heat transfer through adjustable spring-loading
- Easy installation and removal, no tools needed
- Explosion-protected versions
Identification
| Model | TR53 |
| Subcategory | Resistance thermometer |
Measuring range
| Temperature ranges | −50…+250 °C · −196…+600 °C · −50…+500 °C · −100…+450 °C · −30…+300 °C · +0…+150 °C · −196…+450 °C |
Process conditions
| Process connection | M10 x 1M14 x 1.5G ¼ BG ⅜ BG 1/4 BG 3/8 B |
| Process temperature | −50…+400 °C |
Electrical characteristics
| Electrical connection | 2-wire, 3-wire, 4-wire |
Materials
| Probe material | Stainless steel |
Operating environment
| Ambient temperature | −60…+150 °C |
| IP rating | IP65 |
Certifications and approvals
| Certifications | RoHSEACGOSTMTSCHSBelGIMUkrSEPROUzstandardKazInMetrINMETRONEPSIPESOKCs - KOSHADNOP - MakNIICEATEXIECEx |
| Explosion protection | [Ex ia IIC T1 ... T6 Ga][Ex ia IIIC T125 ... T65 °C Da][Ex ib IIC T3 ... T6 Ga/Gb][Ex ib IIC T3 ... T6 Gb][Ex ia IIC T3 ~ T6][Ex ia/ib IIC T3 ~ T6][II 1G Ex ia IIC T3, T4, T5, T6 Ga][II 1G Ex ia IIC T1 ... T6 Ga][II 1/2G Ex ia IIC T1 ... T6 Ga/Gb][II 2G Ex ia IIC T1 ... T6 Gb][II 1D Ex ia IIIC T125 ... T65 °C Da][II 1/2D Ex ia IIIC T125 ... T65 °C Da/Db][II 2D Ex ia IIIC T125 ... T65 °C Db][II 3G Ex nA IIC T1 ... T6 Gc X][II 3D Ex tc IIIC T440 ... T80 °C Dc X][Ex ia IIC T1 ... T6 Ga/Gb][Ex ia IIC T1 ... T6 Gb][Ex ia IIIC T125 ... T65 °C Da/Db][Ex ia IIIC T125 ... T65 °C Db][0 Ex ia IIC T3/T4/T5/T6][1 Ex ib IIC T3/T4/T5/T6][DIP A20 Ta 65 °C/Ta 95 °C/Ta 125 °C][DIP A21 Ta 65 °C/Ta 95 °C/Ta 125 °C][Ex nA IIC T6 ... T1][DIP A22 Ta 80 ... 440 °C][Ex ia IIC T3 ... T6 Ga][Ex ib IIIC T125 ... T65 °C Da/Db][Ex ib IIIC T125 ... T65 °C Db][Ex ib IIC T3 ~ T6][Ex ia IIC T4 ... T6][Ex ib IIC T4 ... T6][II 2G Ex ia IIC T3, T4, T5, T6 Gb][II 1D Ex ia IIIC T65, T95, T125 °C Da][II 2D Ex ib IIIC T125 ... T65 °C Db]II 1G Ex ia IIC T1...T6 GaII 1/2G Ex ia IIC T1...T6 Ga/GbII 2G Ex ia IIC T1...T6 GbII 1D Ex ia IIC T125...T65℃ DaII 1/2D Ex ia IIC T125...T65℃ Da/DbII 2D Ex ia IIC T125...T65℃ DbII 3G Ex nA IIC T1...T6 Gc XII 3D Ex tc IIIC T440...T80℃ Dc X0 Ex ia IIC T3/T4/T5/T61 Ex ib IIC T3/T4/T5/T6DIP A20 Ta 65 °C/Ta 95 °C/Ta 125 °CDIP A21 Ta 65 °C/Ta 95 °C/Ta 125 °CEx nA IIC T6...T1DIP A22 Ta 80...440 °CEx ia IIC T3...T6 GaEx ib IIC T3...T6 Ga/GbEx ib IIC T3...T6 GbEx ia IIC T125...T65 °C DaEx ib IIC T125...T65 °C Da/DbEx ib IIC T125...T65 °C DbEx ia IIC T3 ~T6Ex ia/lib IIC T3 ~T6Ex ib IIC T3 ~T6Ex ia IIC T4...T6Ex ib IIC T4...T6II 1G Ex ia IIC T3, T4, T5, T6 GaII 2G Ex ia IIC T3, T4, T5, T6 GbII 1D Ex ia IIC T65, T95, T125 °C DaII 2D Ex ib IIC T125...T65 °C Db |
Additional details
| Sensor type | Pt100 |
| Sensor class | AA |
| Probe length | 10 mm |
| Probe diameter | 6 mm |
| Thermowell | No |
| Datasheet languages | EN |
Tables from datasheet
| Logo | Description | Country | |
|---|---|---|---|
| EU declaration of conformity ■ RoHS directive | European Union | ||
| - Ex i Zone 0 gas Zone 1 mounting to zone Zone 1 gas Zone 20 dust Zone 21 mounting to zone Zone 21 dust - Ex n Zone 2 gas Zone 22 dust (option) conjunction with ATEX) | [II 1G Ex ia IIC T1 ...T6 Ga] [II 1/2G Ex ia IIC T1 ...T6 Ga/Gb] [II 2G Ex ia IIC T1 ...T6 Gb] [II 1D Ex ia IIIC T125 ...T65 °C Da] [II 1/2D Ex ia IIIC T125 ...T65 °C Da/Db] [II 2D Ex ia IIIC T125 ...T65 °C Db] [II 3G Ex nA IIC T1 ...T6 Gc X] [II 3D Ex tc IIIC T440 ...T80 °C Dc X] | International | |
| IECEx (in Hazardous areas - Ex i Zone 0 gas Zone 1 mounting to zone Zone 1 gas | [Ex ia IIC T1 ...T6 Ga] [Ex ia IIC T1 ...T6 Ga/Gb] [Ex ia IIC T1 ...T6 Gb] |
| Logo | Description | Country |
|---|---|---|
| EAC (option) Hazardous areas | Eurasian Economic Community | |
| Zone 22 dust [DIP A22Ta 80 ... 440 °C] INMETRO (option) Hazardous areas - Ex i Zone 0 gas [Ex ia IIC T3 ...T6 Ga] Zone 1 mounting to zone 0 gas [Ex ib IIC T3 ...T6 Ga/Gb] Zone 1 gas [Ex ib IIC T3 ...T6 Gb] Zone 20 dust [Ex ia IIIC T125 ...T65 °C Da] | Brazil | |
| NEPSI (option) Hazardous areas - Ex i Zone 0 gas [Ex ia IIC T3 ~ T6] Zone 1 mounting to zone 0 gas [Ex ia/ib IIC T3 ~ T6] | China | |
| KCs - KOSHA (option) Hazardous areas Ex i Zone 0 gas [Ex ia IIC T4 ...T6] Zone 1 gas [Ex ib IIC T4 ...T6] | South Korea | |
| - | PESO (option) Hazardous areas - Ex i Zone 0 gas [Ex ia IIC T1 ...T6 Ga] Zone 1 mounting to zone 0 gas [Ex ib IIC T3 ...T6 Ga/Gb] | India |
| Zone 1 gas [Ex ib IIC T3 ...T6 Gb] DNOP - MakNII (option) Hazardous areas - Ex i Zone 0 gas [II 1G Ex ia IIC T3, T4, T5, T6 Ga] | Ukraine | |
| GOST (option) Metrology, measurement technology | Russia | |
| KazInMetr (option) Metrology, measurement technology | Kazakhstan | |
| - | MTSCHS (option) Permission for commissioning | Kazakhstan |
| BelGIM (option) Metrology, measurement technology | Belarus | |
| UkrSEPRO (option) Metrology, measurement technology | Ukraine | |
| Uzstandard (option) Metrology, measurement technology | Uzbekistan |
Tolerance value of the measuring insert per IEC 60751
| Class | Sensor construction | |
|---|---|---|
| Wire-wound | Thin-film | |
| Class B | -196 ...+600 °C -196 ...+450 °C | -50 ...+500 °C -50 ...+250 °C |
| Class A 3) | -100 ...+450 °C | -30 ...+300 °C |
| Class AA 3) | -50 ...+250 °C | 0 ... 150 °C |
| Criterion | Dimensions T inmm | Ø transition inmm |
|---|---|---|
| Probe Ø = transition sleeve Ø | n/a | Identical to probe |
| Ø6mm with crimped transition | 45 | 7 |
| Ø6mm with crimped transition 5) | 45 | 8 |
| Ø8mm with crimped transition | 45 | 10 |
View all (7)
| Probe diameter d inmm | Cable sheath (insulation) silicone | Cable sheath (insulation) PTFE Working temperature -50 ... +250 °C | |||
|---|---|---|---|---|---|
| Working temperature -50 Standard | Shielded | Standard | Shielded | With stainless steel | |
| 6 | 1 x 2-wire | - | 1 x 2-wire | 1 x 2-wire | 1 x 2-wire |
| 1 x 2-wire | - | 1 x 3-wire | 1 x 3-wire | 1 x 3-wire | |
| 1 x 2-wire | - | 1 x 4-wire | 1 x 4-wire | 1 x 4-wire | |
| 1 x 2-wire | - | 2 x 2-wire | 2 x 2-wire | 2 x 2-wire | |
| 8 | 1 x 2-wire | 1 x 2-wire | 1 x 2-wire | 1 x 2-wire | 1 x 2-wire |
| 1 x 3-wire | 1 x 3-wire | 1 x 3-wire | 1 x 3-wire | 1 x 3-wire | |
| 1 x 4-wire | 1 x 4-wire | 1 x 4-wire | 1 x 4-wire | 1 x 4-wire | |
| 2 x 2-wire | 2 x 2-wire | 2 x 2-wire | 2 x 2-wire | 2 x 2-wire | |
| 2 x 3-wire | - | - | 2 x 3-wire | 2 x 3-wire |
| Probe Ø | Process connection | NS | Nipple bore | Spring Ø | Flats | Thread length | Order no. |
|---|---|---|---|---|---|---|---|
| Ø d | Ø NB | Ø FD | SW | i | |||
| 6 | M10 x 1 | 12 | 6,4 | 6 | 14 | 10 | 3120914 |
| M14 x 1,5 | 14 | 8,4 | 6 | 17 | 10 | 3366788 | |
| G¼B | 14 | 8,4 | 6 | 17 | 10 | 3118927 | |
| G⅜B | 14 | 8,4 | 6 | 17 | 11 | 3118901 | |
| 8 | M14 x 1,5 | 14 | 8,4 | 7 | 17 | 10 | 3366788 |
| G¼B | 14 | 8,4 | 7 | 17 | 10 | 3118927 | |
| G⅜B | 14 | 8,4 | 7 | 17 | 11 | 3118901 |
| Certification type | Measuring accuracy | Material certificate |
|---|---|---|
| 2.2 Test report | x | x |
Industry
Oil & Gas
Pipelines and vessels
Industry
Chemistry / Pharma
Plastics processing machinery
Industry
Machinery
Injection moulding machinery
Couldn't find the answer in the documentation? An engineer will reply within a business day.