Multipoint thermocouple in band design
Description
Multipoint thermometers are often used for measuring temperature profiles in reactors or fuel depots or for the detection of the so-called "hotspots".
The so-called multipoint thermometer in band design is a common construction. In this design, several, if required, exchangeable thermocouples or resistance thermometers are linearly arranged on a guide band.
To achieve rapid response times, the individual measuring points are pressed by pressure springs to the internal side of the thermowell which forms a single entity with the thermometer or which can ideally be an already existing component of the reactor. Connection terminals or temperature transmitters are placed in the connection housing which is either a component of the multipoint thermometer or can be mounted separately, e.g. on a wall or pipeline.
Multipoint thermometer in band design model Tx95-B-B
Special features
- Versions to customer specification
- Various process connections
- Exchangeable measuring inserts
- Application in conjunction with a thermowell
- Explosion-protected versions Ex i, Ex n and NAMUR NE24
| Product family | TR95/TC95 |
| Subcategory | Multipoint thermometer |
| Process connection | Threaded connections (male/female)High pressure connections (sealing cone, lens-type sealing ring)Flanges according to ANSI/ASME B16.5, EN 1092-1, DIN 2527Flanges according to ANSI/ASME B16.5Flanges according to EN 1092-1Flanges according to DIN 2527 |
| Electrical connection | Cable compression fittings as per customer specification |
| Probe material | Stainless steel 316L, 1.4571, Special alloys, Carbon steel, Carbon steels |
| Thermowell material | Stainless steel 316, Stainless steel 316L, Stainless steel 1.4571 (316TI) |
| Explosion protection | Ex iEx nNAMUR NE24 |
| Thermowell | Yes |
| Thermowell form | fabricated |
| Datasheet languages | EN |
| Standards | Flange design |
|---|---|
| ASME B16.5 | Nominal width: 2 ... 4" Pressure rating: class 150 ... 2,500 |
| EN 1092-1/DIN 2527 | Nominal width:DN 50 ...DN 200 Pressure rating:PN 16 ...PN 100 |
| Band dimension b | Inner diameter of tube | Band length lB | Number of measuring points |
|---|---|---|---|
| 34x2mm | 38 ...60mm | freely selectable (max. 40 m) | freely selectable (max. 10 MP, minimum distance of |
| 18x2mm | 20 ...45mm | the measuring points: 200 mm) |
| Version | Tube dimension | Length N |
|---|---|---|
| Straight tube design | 60.3 x 5.5mm | 250mm or longer |
| Separable threaded connection | 60.3 x 5.5mm 80 mmflats | 250mm or longer |
| Connection options in the | Terminal enclosure dimensions inmm | ||
|---|---|---|---|
| terminal enclosure | ca. 160 x 160 | ca. 160 x 260 | ca. 250 x 400 |
| Connection terminals | up to 10MP | up to 10MP | up to 10MP |
| Transmitters | up to4MP | up to8MP | up to 10MP |
| Transmitter on terminal | up to3MP | up to6MP | up to 10MP |
| Terminal on transmitter on terminal | up to2MP | up to4MP | up to8MP |
Couldn't find the answer in the documentation? An engineer will reply within a business day.