Threaded or weld-in protection tube
Description
Each thermowell/protection tube is an important component of any temperature measurement point. It is used to separate the process from the surrounding area, thus protecting the environment and operating personnel and keeps aggressive media, high pressures and flow rates from the temperature sensor itself and thereby enables the thermometer to be exchanged during operation.
Based on the almost limitless application possibilities, there are a large number of variants, such as designs or materials of the thermowell/protection tube. The type of process connection and the basic method of manufacture are important design differentiation criteria. A basic differentiation can be made between threaded and weld-in thermowells/ protection tube, and those with flange connections.
Special features
- Cost-effective design
- Quick adjustability and replaceability of thermometers
| Model | SWT52G |
| Product family | SWT52 |
| Subcategory | Protection tube |
| Temperature ranges | −200…+160 °C · −200…+500 °C |
| Process connection | G ½ B threadWelding stud |
| Process temperature | ≤ +500 °C |
| Thermowell material | St35, Copper alloy, Stainless steel |
| Probe diameter | 8 mm |
| Thermowell | Yes |
| Thermowell form | fabricated |
| Datasheet languages | EN |
| Versions | ■ Model SWT52G:Protection tube with thread ■ Model SWT52S:Protection tube with welding stud |
|---|---|
| Protection tube material | ■ Copper alloy ■ St35 1) ■ Stainless steel |
| Process connection | |
| Model SWT52G | G½Bthread |
| Model SWT52S | Welding stud |
| Connection to thermometer | Suitable for thermometers with smooth connection (without threads) Collar Ø18 mm[0.70 in] Fixing via M4 retaining screw |
| Bore size | Ø8mm[0.31 in], for thermometer model 52 |
| Insertion length U | Suitable for the various standard insertion lengths, l 1 , of thermometer model 52 |
| Max. process temperature, process pressure | Depending on: ■ Thermowell design - Dimensions - Material ■ Process conditions - Flow rate - Density of medium |
| Copper alloy (6 bar stat.) | 160 °C |
| St35 or stainless steel (25 bar stat.) | 500 °C |
| l 1 | E | SW | Ø F 1 | Ø D 1 |
|---|---|---|---|---|
| 45 [1.77] | G½B | 27 [1.125 in] | 10 [0.39] | 26 [1.02] |
| 63 [2.48] | G½B | 27 [1.125 in] | 10 [0.39] | 26 [1.02] |
| 100 [3.93] | G½B | 27 [1.125 in] | 10 [0.39] | 26 [1.02] |
| 160 [6.29] | G½B | 27 [1.125 in] | 10 [0.39] | 26 [1.02] |
| 200 [7.87] | G½B | 27 [1.125 in] | 10 [0.39] | 26 [1.02] |
| l 2 | Ø d 5 | Ø F 1 |
|---|---|---|
| 43 [1.69] | 24 [0.94] | 10 [0.39] |
| 80 [3.14] [0.51] | 24 [0.94] | 10 [0.39] |
| 140 [5.51] | 24 [0.94] | 10 [0.39] [1.29] |
| 180 [7.08] | 24 [0.94] | 10 [0.39] |
| Process connection | Insertion length, l 1 , of the thermometer |
|---|---|
| Thread | l 1 = insertion length, l 1 , of the thermowell |
| Welding stud | l 1 = insertion length, l 2 , of the thermowell + 20 mm[0.8 in] |