Single point load cell
Description
The model F4884 single point load cells are a range of aluminium single point load cells suitable for a wide range of applications. Thanks to their standardised geometry and simple design, they can be easily installed in all types of scales.
The model F4884 load cells are adapted to the special requirements of checkweighers and feature a particularly short settling time, so that the weight of the goods being recorded can be determined as quickly as possible.
The load cells are also suitable for use in sectors such as industry, commerce, medicine and research.
Load cell, model F4884
The model F4884 single point load cells also feature high accuracy and react quickly . They are also insensitive to lateral and corner loading.
The load cells are easy to handle due to their simple force introduction. This is made perpendicular to the geometry.
Special features
- Measuring ranges 0 ... 50 kg to 0 ... 635 kg [0 ... 110 lbs and 0 ... 1,400 lbs]
- Load cell made from aluminium
- High accuracy, react quickly, low settling time
- Insensitive to lateral and corner load
- Simple design, easy installation
Build a SPP-F4884 for your task
The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.
- ModelF4884 Single point load cell aluminium 0 ... 50 kg to 0 ... 635 kg
- Force directioncompression
- Unitskg
- Rated force/Rated load—
- Relative linearity error±0.02% Fnom
- Output signal2.0 ±0.2 mV/V
- Electrical connectionCable output, free wires
- Cable length2 m
- Cable diameterØ5 mm
Finish your configuration
Select every option to submit the request.
| Model | F4884 |
| Subcategory | Single point load cell |
| Force ranges | 0…50 kg · 0…75 kg · 0…100 kg · 0…150 kg · 0…200 kg · 0…250 kg · 0…300 kg · 0…500 kg · 0…635 kg · 0…110 lbf · 0…165 lbf · 0…220 lbf · 0…331 lbf · 0…441 lbf · 0…551 lbf · 0…661 lbf · 0…1102 lbf · 0…1400 lbf |
| Accuracy class | ±0.02 % Fnom |
| Process temperature | −10…+40 °C |
| Mounting type | Single-point |
| Output signal | 2.0 ±0.2 mV/V |
| Cell material | Aluminium |
| Ambient temperature | −20…+65 °C |
| IP rating | IP67 |
| Weight | 2 kg |
| Certifications | RoHSUKCAEAC |
| Overload protection | 150 % |
| Cable length | 2 m |
| Datasheet languages | EN |
| Rated load F nom kg | 50 | 75 | 100 | 150 | 200 | 250 300 | 500 | 635 |
|---|---|---|---|---|---|---|---|---|
| Rated load F nom lbs | 110 | 165 | 220 | 331 | 441 | 551 661 | 1,102 | 1,400 |
| Relative linearity error d lin 1) | ±0.02%F nom | |||||||
| Relative creep, 30 min. | ±0.02%F nom | |||||||
| Relative reversibility error v | ±0.02%F nom | |||||||
| Relative deviation of zero signal d S, 0 | ±5%F nom | |||||||
| Temperature effect on zero signalTK 0 | ≤ ±0.02 %/10 K | |||||||
| Temperature effect on characteristic value TK C | ≤ ±0.02 %/10 K | |||||||
| Force limit F L | 150%F nom | |||||||
| Breaking force F B | 200%F nom | |||||||
| Material of the measuring body | Aluminium | |||||||
| Rated temperature range B T;nom | -10 …+40 °C [14 ... 104 °F] | |||||||
| Operating temperature range B T, G | -20 …+65 °C [-4 ... 149 °F] | |||||||
| Input resistance R e | 410 ±20Ω | |||||||
| Output resistance R a | 350 ±5Ω | |||||||
| Insulation resistance R is | ≥ 5,000 MΩ/DC 100V | |||||||
| Output signal (rated characteristic value) C nom | 2.0 ±0.2 mV/V | |||||||
| Electrical connection | Measuring cable ∅5x2,000 mm[∅0.197 x 78.74 in] | |||||||
| Supply voltage U B, nom | DC 5 ...10V (max. 15 V) | |||||||
| Ingress protection (per IEC/EN 60529) | IP67 | |||||||
| Platform size | 600 x 600 mm[23.62 x 23.62 in] | |||||||
| Weight | 2 kg [4.41 lbs] |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity RoHS directive | European Union | |
| UKCA RoHS directive | United Kingdom |
| Logo | Description | Region |
|---|---|---|
| EAC | Eurasian Economic Community |
| Supply voltage+ | Exc+ | Red |
|---|---|---|
| Supply voltage- | Exc- | Green |
| Signal+ | Sig+ | Black |
| Signal- | Sig- | White |
| Shield | Shield | Yellow-green |
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →2 standard articles of family F4884
If you know the code — pick directly. If not — use the configurator in mode “01”.