Single point load cell
Description
The model F4881 single point load cells are a range of aluminium single point load cells suitable for a wide range of applications. Thanks to their standardised geometry and simple design, they can be easily installed in all types of scales.
The model F4881 load cells are adapted to the special requirements of multihead combination weighers and feature a particularly short settling time, so that the weight of the goods being combined can be determined as quickly as possible.
The load cells are also suitable for use in sectors such as industry, commerce, medicine and research.
Load cell, model F4881
The model F4881 single point load cells also feature high accuracy and react quickly. They are also insensitive to lateral and corner loading.
The load cells are easy to handle due to their simple force introduction. This is made perpendicular to the geometry.
Special features
- Measuring ranges 0 ... 2 kg to 0 ... 30 kg [0 ... 4 lbs to 0 ... 66 lbs]
- Load cell made from aluminium
- High accuracy, react quickly, low settling time
- Insensitive to lateral and corner load
- Simple design, easy installation
Build a SPP-F4881 for your task
The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.
- ModelF4881 Single point load cell aluminium 0 ... 2 kg to 0 ... 30 kg
- DesignDesign A
- Force directioncompression
- Unitskg
- Rated force/Rated load—
- Relative linearity error±0.02% Fnom
- Output signal2.0 ±0.2 mV/V
- Electrical connectionCable output, free wires
- Cable length0.25 m
- Cable diameterØ3 mm
Finish your configuration
Select every option to submit the request.
| Model | F4881 |
| Product family | F488 |
| Subcategory | Single point |
| Force ranges | 0…2 kg · 0…3 kg · 0…5 kg · 0…8 kg · 0…15 kg · 0…30 kg · 0…4 lbf · 0…7 lbf · 0…11 lbf · 0…18 lbf · 0…33 lbf · 0…66 lbf |
| Accuracy class | ±0.02 % Fnom |
| Process temperature | −10…+40 °C |
| Mounting type | Single-point |
| Output signal | 2.0 ±0.2 mV/V |
| Cell material | Aluminium |
| Ambient temperature | −20…+65 °C |
| IP rating | IP67 |
| Weight | 0.2 kg |
| Certifications | RoHSUKCAEACCE |
| Overload protection | 150 % |
| Cable length | 0.25 m |
| Datasheet languages | EN |
| Model F4881 | ||||||
|---|---|---|---|---|---|---|
| Rated load F nom kg | 2 | 3 | 5 | 8 | 15 | 30 |
| Rated load F nom lbs | 4 | 7 | 11 | 18 | 33 | 66 |
| Relative linearity error din lin 1) | ±0.02%F nom | |||||
| Relative creep, 30 min. | ±0.02%F nom | |||||
| Relative reversibility error v | ±0.02%F nom | |||||
| Relative deviation of zero signal d S,0 | ±5%F nom | |||||
| Temperature effect on zero signalTK 0 | ≤ ±0.014 %/ 10 K | |||||
| Temperature effect on characteristic value TK C | ≤ ±0.02 %/ 10 K | |||||
| Force limit F L | 150%F nom | |||||
| Breaking force F B | 200%F nom | |||||
| Material of the measuring body | Aluminium | |||||
| Rated temperature range B T;nom | -10 ...+40 °C [14 ... | °F] | ||||
| Operating temperature range B T, G | -20 ...+65 °C [-4 ... | °F] | ||||
| Input resistance R e | 410 ±10Ω | |||||
| Output resistance R a | 350 ±5Ω | |||||
| Insulation resistance R is | ≥ 5,000 MΩ/DC 100V | |||||
| Output signal (rated characteristic value) C nom | 2.0 ±0.2 mV/V | |||||
| Electrical connection | ||||||
| Design A: 2 kg; 3 kg; 5 kg; 8 kg [4.4 lbs; 6.6 lbs; 11 lbs; 17.6 lbs] | Measuring cable ∅3x250 mm[∅0.13 x 9.84 in] | |||||
| Design B: 5 kg; 8 kg [11 lbs; 17.6 lbs] | Measuring cable ∅3x360 mm[∅0.13 x 14.17 | |||||
| Design B: 30 kg [66 lbs] | Measuring cable ∅3x2,000 mm[∅0.13 x 78.74 | |||||
| Design C: 15 kg [33 lbs] | Measuring cable ∅3x250 mm[∅0.13 x 9.84 | |||||
| Design C: 30 kg [66 lbs] | Measuring cable ∅3x250 mm[∅0.13 x 9.84 | |||||
| Supply voltage U B , nom | DC 5 ...10V (max. 15 V) | |||||
| Ingress protection (per IEC/EN 60529) | IP67 | |||||
| Platform size | Design A: 300 x 300 mm[11.81 x 11.81 in] |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity RoHS directive | European Union | |
| UKCA RoHS directive | United Kingdom |
| Logo | Description | Region |
|---|---|---|
| EAC | Eurasian Economic Community |
| Rated load in kg | Dimensions inmm | |||||
|---|---|---|---|---|---|---|
| A | B | C | D | E | G | |
| 5 | 20 | 80 | 28 | 50 | 13 | 13 |
| 8 | 20 | 80 | 28 | 50 | 13 | 360 |
| 30 | 20 | 80 | 28 | 50 | 13 | 2,000 |
View all (7)
| Rated load in lbs | Dimensions in inch | |||||
|---|---|---|---|---|---|---|
| A | B | C | D | E | G | |
| 11.02 | 0.79 | 3.15 | 1.10 | 1.97 | 0.51 | 0.51 |
| 17.64 | 0.79 | 3.15 | 1.10 | 1.97 | 0.51 | 14.17 |
| 66 | 0.79 | 3.15 | 1.10 | 1.97 | 0.51 | 78.74 |
| H | I | J | K | L | M | N |
|---|---|---|---|---|---|---|
| 0.20 | 1.18 | 0.20 | 0.20 | 9.84 | 0.59 | 0.47 |
| Supply voltage+ | Exc+ | Red |
|---|---|---|
| Supply voltage- | Exc- | Green |
| Signal+ | Sig+ | Black |
| Signal- | Sig- | White |
| Shield | Shield | Yellow-green |