Compression force transducer with strain gauge
Description
Compression force transducers are used for the determination of compression forces in a wide variety of applications and are suitable for static and dynamic measuring requirements.
Force transducers of the F1201 series, due to their compactness, are very frequently used in industrial applications and in the lifting platforms. The spherical cap (load introduction button) allows for a very simple force introduction. The standard mounting position of the force transducer is horizontal or vertical.
The force transducer is hermetically sealed and welded, correspondingly splash-proof and, thanks to an ingress protection of IP68, works reliably, even under difficult operating conditions.
Compression force transducer, model F1201
Special features
- Measuring ranges 0 ... 5 t [0 ... 11,023 lb] to 0 ... 30 t [0 ... 66,139 lb]
- Measuring element from stainless steel
- Hermetically sealed and welded, ingress protection IP68
Build a SPP-F1201 for your task
The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.
- ModelF1201 Compression force transducer Standard, big diameter, up to 300 kN
- Force directioncompression
- Rated force/Rated load—
- Relative linearity error0.025% Fnom
- Output signal2.0 ±0.1 % mV/V
- Electrical connectionCable output, free wires
- Cable length10 m
- Cable diameterØ4 mm
Finish your configuration
Select every option to submit the request.
| Model | F1201 |
| Subcategory | Compression force transducer |
| Force ranges | 0…5 t · 0…10 t · 0…30 t · 0…11023 lbf · 0…66139 lbf |
| Accuracy class | C3 |
| Process temperature | −10…+40 °C |
| Mounting type | Compression |
| Output signal | 2.0 ±0.1 % mV/V |
| Cell material | Stainless steel |
| Ambient temperature | −50…+70 °C |
| IP rating | IP68/IP69K |
| Weight | 1.1 kg |
| Certifications | RoHSEU declaration of conformityRoHS-directiveCE |
| Overload protection | 150 % |
| Cable length | 10 m |
| Datasheet languages | EN |
| Model F1201 | |
|---|---|
| Rated load F nom t | 5, 10, 30 |
| Combined error (Non-linearity and hysteresis) | < ±0.025%F nom |
| Relative creep, 30 min. | < ±0.024%F nom |
| Limit force F L | 150%F nom |
| Breaking force F B | 200%F nom |
| Material of the measuring body | Stainless steel |
| Temperature error | |
| Zero point | < ±0.02%F nom /10 K |
| Characteristic value | < ±0.018%F nom /10 K |
| Rated temperature range B T, nom | -10 …+40 °C |
| Operating temperature range B T, G | -50 …+70 °C |
| Input resistance R e | 800 ±30 Ω |
| Output resistance R a | 700 ±5 Ω |
| Insulation resistance R is | > 5,000MΩ |
| Rated displacement (at F nom ) | < 0.6mm |
| Output signal (rated characteristic value ) C nom | 2.0 ±0.1 %mV/V |
| Electrical connection | Cable Ø4 × 10m |
| Material of the electrical connection | PVC |
| Supply voltage U B | DC 10V ...15V |
| Ingress protection (per IEC/EN 60529) | IP68 and IP69K |
| Weight | |
| 5 t, 10 t | 1.1 kg |
| 30 t | 2.8 kg |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity | European Union | |
| RoHS-directive |
| Rated load in t | Dimensions inmm | |||||
|---|---|---|---|---|---|---|
| ∅A | B | C | ∅D | E | R | |
| 5, 10 | 82 | 44 | 32 | 22 | 12 | 130 |
| 30 | 126 | 54 | 40 | 35 | 14 | 200 |
| Excitation voltage (Exc+) | Green |
|---|---|
| Excitation voltage (Exc-) | Black |
| Signal (Sig+) | Red |
| Signal (Sig-) | White |
| Shield | Shield |
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →3 standard articles of family F1201
If you know the code — pick directly. If not — use the configurator in mode “01”.