Bourdon tube pressure gauge with wireless transmission
Description
The IIoT-capable model PGW2x.100 pressure gauge finds its use wherever the process pressure has to be indicated on-site and, at the same time, centralised, web-based remote monitoring is required.
The model PGW2x.100 is based on a fully welded and robust Bourdon tube measuring system. It therefore combines the mechanical measuring system with electronic signal processing.
Battery-operated wireless transmission via LoRaWAN ® ('Long Range Wide Area Network') is based on LPWAN technology ('Low Power Wide Area Network') to enable high transmission ranges and long battery life.
IIoT-capable Bourdon tube pressure gauge, model PGW23.100
The model PGW2x.100 pressure gauge fulfils safety-related requirements of the relevant standards and regulations for the on-site indication of the operating pressure of pressure vessels, as well as the requirements of the Radio Equipment Directive for data communication. In particular, the LoRaWAN ® network enables the complete end-to-end encryption with bidirectional communication for safe IIoT applications.
The model PGU2x.100 is based upon a model 2xx.30 high-quality pressure gauge with a nominal size of 100, which corresponds to the S3 safety version of the EN 837-1.
Special features
- IIoT-capable measuring instrument with mechanical on-site indication
- Battery-operated LoRaWAN ® wireless transmission based on LPWAN technology
- High transmission range up to 10 km [6 mi] with long battery life (up to 5 years)
- Stainless steel version, model PGW23.100 or Monel version, model PGW26.100
- Measuring ranges from 0 … 0.6 to 0 ... 1,600 bar [0 ... 10 to 0 ... 20,000 psi] as well as vacuum and +/- measuring ranges
Build a PGW2X for your task
The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.
- ModelPGW23
- Nominal size100
- Radio standardLoRaWAN® 868 EU
- On-site interfaceNFC
- Liquid Damping (case filling)without filling
- Unit of outer Scalebar
- Measuring rangegauge pressure range
- Scale range—
- 2nd Scale or Special Scalewithout
- Process connection—
- Restrictorwithout
- Special design featureswithout
- AntennaStraight antenna (Pulse W5017)
- Assembly accessorywithout
Finish your configuration
Select every option to submit the request.
| Model | PGW23.100 |
| Product family | PGW23 |
| Subcategory | Wireless pressure gauge |
| Pressure ranges | 0…0.6 bar · 0…1600 bar · 0…10 psi · 0…20000 psi · 0…0.06 MPa · 0…60 kPa · 0…100000 kPa · 0…600 mbar · 0…1600 mbar · -1…3 bar · 0…10 bar · 0…160 bar · 0…600 bar · 0…250 psi · 0…3000 psi · 0…4000 psi · 0…5000 psi · 0…0.1 MPa · 0…0.16 MPa · 0…0.25 MPa · 0…0.4 MPa · 0…0.6 MPa · 0…100 kPa · 0…400 kPa · 0…600 kPa · 0…1000 kPa · 0…1600 kPa · 0…2500 kPa · 0…4000 kPa · 0…6000 kPa · 0…10000 kPa · 0…16000 kPa · 0…25000 kPa · 0…40000 kPa · 0…60000 kPa · 0…1000 mbar · 0…1200 mbar · 0…2500 mbar · -0.6…0 bar · -1…0 bar · -1…0.6 bar · -1…1.5 bar · -0.06…0 MPa · -0.1…0 MPa · -0.1…0.06 MPa · -0.1…0.15 MPa · -0.1…0.3 MPa · -60…0 kPa · -100…0 kPa · -100…60 kPa · -100…150 kPa · -100…300 kPa · -600…0 mbar · -1000…0 mbar · -1000…600 mbar · -1000…1500 mbar · -1000…3000 mbar · -30…0 inHg · -30…100 inHg · -30…15 inHg · -30…30 inHg · -30…60 inHg · -30…150 inHg · -30…300 inHg · 0…160 MPa · 0…0.6 kg/cm2 · 0…1600 kg/cm2 · -100…3000 kPa · -1…30 kg/cm2 |
| Accuracy class | 1.0 |
| Accuracy standard | EN 837-1 |
| Process connection | G 1/4 BG 1/2 BM20 x 1.51/4 NPT1/2 NPT |
| Process temperature | −40…+100 °C |
| Output signal | LoRaWAN® 868 MHz EU · LoRaWAN® |
| Power supply | DC 3.6 V |
| Electrical connection | Battery (SAFT LS17500) |
| Case material | Stainless steel 1.4301 (304), Stainless steel 1.4571 (316Ti), Bayonet bezel, stainless steel, Panel mounting flange, stainless steel |
| Wetted parts material | Stainless steel 1.4404 (316L), Monel |
| Sealing material | Silicone oil |
| Ambient temperature | −40…+60 °C |
| IP rating | IP54 |
| Weight | 0.8 kg |
| Certifications | CERoHSUKCA |
| Dial size | 100 mm |
| Datasheet languages | EN, DE |
| Further version | ■ Oil- and grease-free ■ For oxygen, oil- and grease-free ■ Monel version; model PGW26.100 |
|---|---|
| Nominal size (NS) | Ø100 mm[4"] |
| Window | Laminated safety glass |
| Connection location | Lower mount (radial) |
| Case | |
| Design | Safety level 'S3' per EN 837-1:With solid baffle wall (Solidfront) and blow-out back |
| Material | ■ Stainless steel 1.4301 (304) ■ Stainless steel 1.4571 (316Ti) |
| Ring | Bayonet bezel, stainless steel |
| Mounting | ■ Without ■ Panel mounting flange, stainless steel |
| Case filling | ■ Without ■ Silicone oil |
| Movement | Copper alloy |
| Radio case | PBT plastic, glass-fibre reinforced |
| Antenna | Thermoplastic elastomer (TPE) |
| Antenna connection (SMA) | Brass, gold-plated |
| Type of measuring element | Bourdon tube, C-type or helical type |
|---|---|
| Material | |
| PGW23.100 | Stainless steel 1.4404 (316L) |
| PGW26.100 | Monel 400 (2.4360) |
| Accuracy class 1) | 1.0 per EN 837-1 |
|---|---|
| Temperature error | On deviation from the reference conditions at the measuring system: ≤ ±0.4 %per 10 °C [≤ ±0.4 %per 18 °F] of full scale value |
| Reference conditions | |
| Ambient temperature | +20 °C [+68 °F] |
| bar | ||
|---|---|---|
| 0 ... 0.6 0 ... 1 | 0 ... 10 0 ... 16 | 0 ... 160 0 ... 250 |
| 0 ... 1.6 | 0 ... 25 | 0 ... 400 |
| 0 ... 2.5 | 0 ... 40 | 0 ... 600 |
| 0 ... 4 | 0 ... 60 | 0 ... 1,000 |
| 0 ... 6 | 0 ... 100 | 0 ... 1,600 1) |
View all (20)
| kPa | ||
|---|---|---|
| 0 ... 60 0 ... 100 | 0 ... 1,000 0 ... 1,600 | 0 ... 16,000 0 ... 25,000 |
| 0 ... 160 | 0 ... 2,500 | 0 ... 40,000 |
| 0 ... 250 | 0 ... 4,000 | 0 ... 60,000 |
| 0 ... 400 | 0 ... 6,000 | 0 ... 100,000 |
| 0 ... 600 | 0 ... 10,000 | - |
| MPa | 0 ... 1 | |
|---|---|---|
| 0 ... 0.06 0 ... 0.1 | 0 ... 1.6 | 0 ... 16 0 ... 40 |
| 0 ... 0.16 | 0 ... 2.5 | 0 ... 60 |
| 0 ... 0.25 | 0 ... 4 | 0 ... 100 |
| 0 ... 0.4 | 0 ... 6 | 0 ... 160 1) |
| 0 ... 0.6 | 0 ... 10 | - |
| bar | |
|---|---|
| -0.6 ... 0 | -1 ...+5 |
| -1 ... 0 | -1 ...+9 |
| -1 ... +0.6 | -1 ...+15 |
| -1 ... +1.5 | -1 ...+24 |
| -1 ...+3 | -1 ...+30 |
| -60 ... 0 | -100 ...+500 |
|---|---|
| -100 ... 0 | -100 ...+900 |
| -100 ...+60 | -100 ... +1,500 |
| -100 ...+150 | -100 ... +2,400 |
| -100 ...+300 | -100 ... +3,000 |
| -0.06 ... 0 | -0.1 ... +0.5 |
|---|---|
| -0.1 ... 0 | -0.1 ... +0.9 |
| -0.1 ... +0.06 | -0.1 ... +1.5 |
| -0.1 ... +0.15 | -0.1 ... +2.4 |
| -0.1 ... +0.3 | -0.1 ...+3 |
| mbar | ||
|---|---|---|
| 0 ... 600 | 0 ... 1,100 | 0 ... 1,600 |
| 0 ... 1,000 | 0 ... 1,200 | 0 ... 2,500 |
| kg/cm 2 | 0 ... 10 | |
|---|---|---|
| 0 ... 0.6 0 ... 1 | 0 ... 16 | 0 ... 160 0 ... 250 |
| 0 ... 1.6 | 0 ... 25 | 0 ... 400 |
| 0 ... 2.5 | 0 ... 40 | 0 ... 600 |
| 0 ... 4 | 0 ... 60 | 0 ... 1,000 |
| 0 ... 6 | 0 ... 100 | 0 ... 1,600 1) |
| psi | ||
|---|---|---|
| 0 ... 10 0 ... 15 | 0 ... 250 0 ... 300 | 0 ... 3,000 0 ... 4,000 |
| 0 ... 30 | 0 ... 400 | 0 ... 5,000 |
| 0 ... 60 | 0 ... 600 | 0 ... 6,000 |
| 0 ... 100 | 0 ... 800 | 0 ... 7,500 |
| 0 ... 150 | 0 ... 1,000 | 0 ... 10,000 |
| 0 ... 160 | 0 ... 1,500 | 0 ... 15,000 |
| 0 ... 200 | 0 ... 2,000 | 0 ... 20,000 1) |
| -600 ... 0 | -1,000 ...+600 |
|---|---|
| -1,000 ... 0 | -1,000 ... +1,500 |
| -1,100 ... 0 | -1,000 ... +3,000 |
| -1,200 ... 0 | - |
| -0.6 ... 0 | -1 ...+5 |
|---|---|
| -1 ... 0 | -1 ...+9 |
| -1 ... +0.6 | -1 ...+15 |
| -1 ... +1.5 | -1 ...+24 |
| -1 ...+3 | -1 ...+30 |
| -30 inHg ... 0 | -30 inHg ...+100 |
|---|---|
| -30 inHg ...+15 | -30 inHg ...+150 |
| -30 inHg ...+30 | -30 inHg ...+300 |
| -30 inHg ...+60 | - |
| On-site interface | NFC (near field communication) |
|---|---|
| Standard | ISO/IEC 15693 type 5 tag |
| Frequency | 13.56 MHz |
| LoRaWAN ® radio standard | |
|---|---|
| LoRaWAN ® specification | LoRaWAN ® 868 MHz EU |
| LoRaWAN ® protocol | 1.0.3 |
| Functions | ■ Registration ■ Configuration of measuring and transmission rate ■ Sending measured values ■ Alarm management |
| Frequency range | 863 - 870 MHz |
| Transmission power | 12 dBm |
| Range in free field 1) | ≤ 10 km |
| Approved antennas | ■ Rigid antenna (Pulse W5017) ■ Antenna with extended cable (Linx ANT-868-ID-2000-SMA) |
| Antenna gain | |
| Rigid antenna (Pulse W5017) | +2 dBm |
| Antenna with extended cable (Linx ANT-868-ID-2000-SMA) | +0.6 dBm |
| Number of channels | 10 |
| Channel spacing | 200 kHz |
| Bandwidth | 125 kHz |
| Max. output power | 14 dBm |
| Measuring rate 2) | |
| For > -20 °C [-4 °F] | Adjustable: 10 seconds to transmission rate, however max. 18 hours |
| For ≤ -20 °C [-4 °F] | Adjustable: 1 minute to transmission rate, however max. 18 hours |
| Transmission rate 3) | Adjustable: 30 minutes to 7 days (maximum transmission rate limited per ETSI EN 300 220 4) ) |
| Security | Full end-to-end encryption →For details on security, see website: https://lora-alliance.org |
| Battery | Lithium thionyl chloride battery (model SAFT LS17500), interchangeable |
|---|---|
| Battery voltage | DC 3.6V |
| Battery life 1) | ≤ 5 years |
| Place of use | Taking into account the following operating conditions, the instrument can be used in indoor and outdoor areas. |
|---|---|
| Altitude | ≤ 2,000 m[6,561 ft] above sea level |
| Medium temperature range | -40 ...+100 °C [-40 ...+212 °F] |
| Ambient temperature range | -40 ...+60 °C [-40 ...+140 °F] |
| Storage temperature range | -40 ...+70 °C [-40 ...+158 °F] |
| Pressure limitation | |
| Steady | Full scale value |
| Fluctuating | 0.9 x full scale value |
| Short time | 1.3 x full scale value |
| Relative humidity, condensation | 0 ... 75 %r.h. (non-condensing) |
| Ingress protection (IP code) per IEC 60529 | ■ IP54 ■ IP65 1) (case filling) |
| Permissible pollution degree per EN 61010-1 | 3 |
| Weight | ■ 0.8 kg [2.14 lb] (for instruments without case filling) ■ 1.1 kg [2.95 lb] (for instruments with case filling) |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity | European Union | |
| Pressure Equipment Directive (pressure accessory, module A) | ||
| Radio Equipment Directive | ||
| EN 61326 emission (group 1, class B) and immunity (industrial application) The instrument may be used without restriction in the following areas:EU and CH, NO, RoHS directive | LI | |
| UKCA | United Kingdom | |
| Pressure equipment (safety) regulations | ||
| Radio equipment regulations | ||
| Restriction of hazardous substances (RoHS) regulations | ||
| - ICASA | South Africa |
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →86 standard articles of family PGW23
If you know the code — pick directly. If not — use the configurator in mode “01”.