AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
FLRU 1
FLRU
On order
WIKA · Level measurement · Family FLRU

Reed level transmitter for connection to WIKA radio unit

Reed level transmitter for connection to WIKA radio unit, model NETRIS®3, for web-based remote monitoring in liquid media with IIoT capability.
Range
0…6 m
Output
Unified WIKA Interface (UWI)
Accuracy
Resolution: 2.7 mm, 5.5 mm, 7.5 mm, 9 mm depending on contact separation
Protection
IP66/IP68
CERoHSATEXIECExII 1D Ex ia IIIC T* DaII 1/2D Ex ia IIIC T* Da/DbII 2D Ex ia IIIC T* DbII 1G Ex ia IIC T1 - T6 GaII 1/2G Ex ia IIC T1 - T6 Ga/GbII 2G Ex ia IIC T1 - T6 GbII 1G Ex ia IIC T1-T6 GaII 1/2G Ex ia IIC T1-T6 Ga/GbII 2G Ex ia IIC T1-T6 GbEx ia IIC T1...T6 GaEx ia IIC T1...T6 Ga/GbEx ia IIC T1...T6 GbEx ia IIIC T* DaEx ia IIIC T* Da/DbEx ia IIIC T* Db
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The model FLRU level transmitter with reed-chain technology in combination with the WIKA model NETRIS ® 3 radio unit is used wherever web-based remote monitoring of level measurement in liquid media is desired. Condition-based and preventive maintenance through centralised big data analysis is thus possible.

Level transmitters of this model series work on the float principle with magnetic transmission and are used wherever centralised, web-based remote monitoring is required. The float's magnetic system in the guide tube actuates a resistance measuring chain that corresponds to a 3-wire

for further approvals, see page 5

Special features

  • IIoT-capable measuring instrument in combination with WIKA radio unit, model NETRIS ® 3
  • Process- and procedure-specific solutions possible
  • Process temperature:T = -80 ... +200 °C [-112 ... +842 °F]
  • Operating pressure: P = vacuum to 80 bar [1,160 psi]
  • Limit density: ρ ≥ 400 kg/m 3
  • Wide variety of different process connections and materials
  • Intrinsically safe version Ex i
Identification
ModelFLRU
SubcategoryReed-chain level transmitter
Measuring range
Level ranges0.5…6 m · 0…0.5 m · 0…1.5 m · 0…3.5 m · 0…6 m
Process conditions
Process connection
G 1 1/2, male threadG 2, male threadDN 50 ... DN 200, PN 6 ... PN 1002" ... 8", Class 150 ... Class 600DIN EN ISO 228-1 G 1 1/2 male threadDIN EN ISO 228-1 G 2 male threadEN 1092-1 DN 50 ... DN 200, PN 6 ... PN 100ASME B16.5 2" ... 8", Class 150 ... Class 600DIN EN ISO 228-1 G1½ male thread
Process temperature−80…+200 °C
Max process pressure80 bar
Measurement technologyfloat
Electrical characteristics
Output signalUnified WIKA Interface (UWI) · 3-wire potentiometer circuit
Electrical connectionM12 x 1 circular connector (4-pin), B-coded
Materials
Wetted parts materialStainless steel 1.4571 (316Ti), Stainless steel 1.4401 (316L), Stainless steel 1.4404 (316L), Stainless steel 1.4435 (316L), Buna, Titanium
Operating environment
Ambient temperature−40…+105 °C
IP ratingIP66/IP68
Certifications and approvals
Certifications
CERoHSATEXIECEx
Explosion protection
II 1D Ex ia IIIC T* DaII 1/2D Ex ia IIIC T* Da/DbII 2D Ex ia IIIC T* DbII 1G Ex ia IIC T1 - T6 GaII 1/2G Ex ia IIC T1 - T6 Ga/GbII 2G Ex ia IIC T1 - T6 GbEx ia IIC T1...T6 GaEx ia IIC T1...T6 Ga/GbEx ia IIC T1...T6 GbEx ia IIIC T* DaEx ia IIIC T* Da/DbEx ia IIIC T* Db
Additional details
Datasheet languagesEN
Tables from datasheet
Operating conditions
Process temperature range■ -40 ...+120 °C [-40 ...+248 °F] ■ -40 ...+200 °C [-40 ...+392 °F] (high-temperature version)
Ambient and storage temperature range-40 ...+105 °C [-40 ...+221 °F]
Version with FKM O-ring -20 ...+105 °C [-4 ...+221 °F]
Climate class per IEC 60654-1Cx (-40 ...+105 °C [-40 ...+221 °F], 5 ... 95 %r.h.)
Version with FKM O-ring: -20 ...+105 °C [-4 ...+221 °F]
Maximum permissible humidity, condensation100 %r.h., condensation permissible
Maximum operating pressure80 bar [1,160 psi]
Limit densityρ ≥ 400 kg/m 3
Salt mistIEC 60068-2-11
Vibration resistanceEN IEC 60721-3-2Cl.2M4
EN IEC 60068-2-610 ... 55 Hz; 20 m/s 2 10 frequency cycles per axis
Shock resistance per IEC 60068-2-27■ 50g ■ 6 ms ■ 3 axes ■ 3 directions ■ 3 times in each direction
Ingress protection per EN IEC 60529 1)■ IP66 ■ IP68
Mounting positionVertical ± 30°
Hazardous gas atmos- phereTemperature classAmbient temperature range (T a )Process temperature
II 1G Ex ia IIC T1 - T6 Ga II 1/2G Ex ia IIC T1 - T6 Ga/Gb II 2G Ex ia IIC T1 - T6 GbT6-40 ...+50 °C [-40 ...+122 °F]-80 ... +71.5 °C [-112 ... +160.7 °F]
T5-40 ...+75 °C [-40 ...+167 °F]-80 ... +86.5 °C [-112 ... +187.7 °F]
T4-40 ...+105 °C [-40 ...+221 °F]-80 ... +121.5 °C [-112 ... +250.7 °F]
T3-40 ...+105 °C [-40 ...+221 °F]-80 ... +186.5 °C [-112 ... +367.7 °F]
T2-40 ...+105 °C [-40 ...+221 °F]-80 ...+200 °C [-112 ...+392 °F]
T1-40 ...+105 °C [-40 ...+221 °F]-80 ...+200 °C [-112 ...+392 °F]
Hazardous dust/air atmos- pheresPower P iAmbient temperature range (T a )Process temperature
II 1D Ex ia IIIC T* Da II 1/2D Ex ia IIICT Da/Db II 2D Ex ia IIIC T* Db330mW-40 ...+100 °C [-40 ... 212 °F]-80 ... 200 °C [-112 ...+392 °F] - 9 K 1)
LogoDescriptionRegion
EU declaration of conformityEuropean Union
RoHS directive ATEX directive Hazardous areas
IECEx - in combination with ATEX Hazardous areas - Ex i Zone 0 gas Zone 1 mounting to zone 0 gas Zone 1 gas Zone 20 dust Zone 21 mounting to zone 20 dust Zone 21 dustEx ia IIC T1...T6 Ga Ex ia IIC T1...T6 Ga/Gb Ex ia IIC T1...T6 Gb Ex ia IIIC T* Da Ex ia IIIC T* Da/Db Ex ia IIIC T* DbInternational