AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
FLM-H 1
FLM-H
On order
WIKA · Level measurement · Family FLM

Magnetostrictive level transmitter

For sanitary applications, high-resolution measurement principle
Range
0.1…6 m
Output
HART® version 6 · 4 ... 20 mA
Accuracy
< ±0.5 mm
Protection
IP68
3-AFDAEN 10204 2.2EN 10204 3.1ADI-freeII 1 G Ex ia IIC T6…T1 GaII 1/2 G Ex ia IIC T6…T1 Ga/GbII 2 G Ex ia IIC T6…T1 GbII 2 D Ex ia IIIC TX°C DbII 1 GEx ia IICT6…T1 GaII 1/2 GEx ia IICT6…T1 Ga/GbII 2 GEx ia IICT6…T1 GbII 2 D Ex ia IIICTX°C DbEx i Zone 0 gasEx ia IIC T6...T1 GaEx ia IIC T6...T1 Ga/GbEx ia IIC T6...T1 GbEx ia IIC TX°C Db
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The model FLM-H magnetostrictive level transmitter has been specifically designed for the requirements of the pharmaceutical and biotechnology industries. The level transmitter is particularly suitable for the special conditions of CIP/SIP cleaning processes, such as chemical stability towards cleaning liquids and high temperatures.

The guide tube is directly welded to the process connection. This guarantees a crevice-free joint, additional seals are not required.

A special advantage of the level transmitter is its easy parameterisation and fast commissioning.

Special features

  • Fully welded and dead-space free
  • Insensitive to foaming, ideal for interface measurement
  • High-precision level measurement: accuracy < 0.5 mm [0.02 in]
  • 3-A marked hygienic design
Identification
ModelFLM-H
Product familyFLM
SubcategorySterile version, high-precision
Measuring range
Level ranges0.1…4 m · 0.1…6 m
Accuracy
Safety integrity level (SIL)SIL 2 IEC 61508 / IEC 61511
Process conditions
Process connection
DIN 32676DIN 11864-1DIN 11864-2DIN 11864-3BioConnect® threadedBioConnect® flangeBioConnect® clampVARIVENT®ISO 2852 DN 32 ... DN 100DIN 32676 DN 32 ... DN 100ISO 2852 clamp DN 32 ... DN 100DIN 32676 clamp DN 32 ... DN 100DIN 11864-1 aseptic threadDIN 11864-1 aseptic linerDIN 11864-2 aseptic flangeDIN 11864-3 aseptic clampVARIVENT® Form F, N, GClamp ISO 2852 DN32...DN100
Process temperature−40…+250 °C
Max process pressure10 bar
Measurement technologymagnetostrictive
Electrical characteristics
Output signalHART® version 6 · 4 ... 20 mA
Power supplyDC 10 ... 30 V
Electrical connection2-wire, cable gland M16 x 1.5 / M20 x 1.5, M12 connector, ½ NPT thread
Materials
Wetted parts materialStainless steel 1.4435 (316L), Stainless steel 1.4404 (316L), Stainless steel 1.4305
Operating environment
Ambient temperature−40…+85 °C
IP ratingIP68
Certifications and approvals
Certifications
3-AFDAEN 10204 2.2EN 10204 3.1ADI-free
Explosion protection
II 1 G Ex ia IIC T6…T1 GaII 1/2 G Ex ia IIC T6…T1 Ga/GbII 2 G Ex ia IIC T6…T1 GbII 2 D Ex ia IIIC TX°C DbEx i Zone 0 gasEx ia IIC T6...T1 GaEx ia IIC T6...T1 Ga/GbEx ia IIC T6...T1 GbEx ia IIC TX°C Db
Additional details
Datasheet languagesEN
Tables from datasheet
Basic information
Measurement principleMagnetostriction
Measurement accuracy< ±0.5 mm[0.02 in]
Resolution< 0.1 mm[0.004 in]
Sensor housing
Ingress protectionIP68
MaterialStainless steel 1.4305
Guide tube
Max. length LFLM-H■ 14 mm[0.55 in]: 100 ... 4,000 mm[3.94 ... 157 in] ■ 17.2 mm[0.68 in]: 100 ...6,000mm [3.94 ... 236 in]
FLM-H-FLEX, with flexible insert1,500 ... 6,000 mm[59.06 ... 236.22 in]
Diameter D■ 14 mm[0.55 in] ■ 17.2 mm[0.68 in]
Material■ Stainless steel 1.4435 (316L) ■ Stainless steel 1.4404 (316L)
Float
Diameter F■ 50 mm[1.97 in] ■ 55 mm[2.17 in] ■ 80 mm[3.15 in]
Material■ Stainless steel 1.4435 (316L) ■ Stainless steel 1.4404 (316L)
Sealing rangeFloat V80/88/A34/35770 ... 1,162 kg/m³
Float V50/55/17/A34/35995 ... 1,860 kg/m³
Float V55/70/17/A34/3A/35780 ... 1,200 kg/m³
LogoDescriptionRegion
®3-A Hygienic design This instrument is 3-A marked, based on a third party verification for conformance to the 3-A standard.USA
EU declaration of conformityEuropean Union
- Ex i Zone 0 gas Zone 0 / 1 gas Zone 1 gas Zone 21 dust IECEx Hazardous areas - Ex i Zone 0 gasII 1 GEx ia IICT6…T1 Ga II 1/2 GEx ia IICT6…T1 Ga/Gb II 2 GEx ia IICT6…T1 Gb II 2 D Ex ia IIICTX°C Db Ex ia IICT6…T1 GaInternational
LogoDescription
SIL IEC 61508 / IEC 61511SIL 2 Functional safety
-In accordance with EMEA/410/01 free from substances of animal origin (ADI-free) Use of materials without any verifiable risk of infection with BSE/scrapie
Certificates
Certificates■ 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, material proof, indication accuracy, wetted metal parts free from substances of animal origin (ADI-free)) ■ 3.1 inspection certificate per EN 10204 (e.g. material proof for wetted metal parts, indication accuracy, calibration certificate) ■ Proof for hygienic floats: pressure and X-ray test; surface roughness and delta ferrite content ■ Sanitary applications:FDA conformity ■ Confirmation of approval; SIL 2 manufacturer&#x27;s declaration ■ Measurement accuracy: test certificate confirming sensor accuracy ■ Material proof: wetted, pressurised metal parts with subsupplier certificate (melting analysis) ■ Proof for sanitary applications:Ra < 0.38 µm surface roughness of wetted parts ■ Proof of material properties: ferrite: basic material <= 1 %, weld seams<=3%
View all (5)
Replaced modelCurrent modelDescription
FFG-PFLM-SMagnetostrictive level transmitter , standard
FFG-TFLM- TMagnetostrictive level transmitter , high temperature
FFG-TPFLM-PMagnetostrictive level transmitter , plastic
FFG-T-MRVE...FLM-HMagnetostrictive level transmitter , sterile version with dairy coupling
FFG-T-FCFE...FLM-HMagnetostrictive level transmitter , sterile version with clamp
FFG-T-IS...FLM-HMagnetostrictive level transmitter , sterile version with ingolde nossle
746.2xxxSuccessor:FLM-SMagnetostrictive level transmitter (Phönix design)