FLM-CA 1
FLM-CA
On order
WIKA · Level measurement · Family FLM

Magnetostrictive level transmitter

High-resolution measurement principle, compact design
Range
0.1…3 m
Output
4 ... 20 mA · HART® ver. 6
Accuracy
±1.25mm
Protection
IP68
RoHSEMC EN 61326ATEXIECExEMC directive EN 61326RoHS directiveCEEMCNAMUR NE43II 1D Ex ia IIIC T160 °C DaEx ia IIIC T160 °C DaII 2G Ex ia IIC T6 ... T4 GbEx i Ex ia IIC T6 ... T4 GaEx ia IIC T6 ... T4 Ga/GbEx ia IIC T6 ... T4 GbEx i II 1G Ex ia IIC T6 ...T4 GaII 1/2G Ex ia IIC T6 ...T4 Ga/GbII 2G Ex ia IIC T6 ...T4 GbEx i Ex ia IIC T6 ...T4 GaEx ia IIC T6 ...T4 Ga/GbEx ia IIC T6 ...T4 GbEx i II 1G Ex ia IIC T6...T4 GaII 1/2G Ex ia IIC T6...T4 Ga/GbII 2G Ex ia IIC T6...T4 GbII 1D Ex ia IIC T160℃DaEx i Ex ia IIC T6...T4 GaEx ia IIC T6...T4 Ga/GbEx ia IIC T6...T4 GbEx ia IIC T160℃Da
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The model FLM-CA magnetostrictive level transmitter is used for the high-accuracy, continuous level detection of liquids and is based on determining the position of a magnetic float according to the magnetostrictive measurement principle.

The FLM-CA emits a 4 … 20 mA output signal, which is configured via buttons within the probe head. Optionally, the FLM-CA is also available with HART ® protocol as a digital output signal. Probe lengths of 100 mm to 3 m and also various temperature and pressure ranges are possible.

In comparison to the FLM-S, the FLM-CA is particularly notable for its very compact and space-saving design. In addition, it can be used in applications with vibrations up to 4 g.

for further approvals see page 2

Special features

  • Compact and space-saving design
  • Output signal 4 ... 20 mA (NAMUR NE43) or HART ® ver. 6
  • Operating limits: Operating temperature: T = -40 ... +250 °C Operating pressure: P = Vacuum to 40 bar Limit density: ρ ≥ 580 kg/m 3
  • Operating temperature: T = -40 ... +250 °C
  • Operating pressure: P = Vacuum to 40 bar
  • Limit density: ρ ≥ 580 kg/m 3
  • Explosion-protected version (option)
  • Vibration resistant version (option)
Identification
ModelFLM-CA
Product familyFLM
Subcategorymagnetostrictive
Measuring range
Level ranges0.1…1 m · 0.1…3 m
Accuracy
Safety integrity level (SIL)SIL 2
Process conditions
Process connection
ANSI 1/2" ... 2 1/2", class 150 ... 600G 1/2" ... G 2"NPT 1/2" ... NPT 2"EN DN 20 ... DN 65, PN 6 ... PN 100DIN DN 20 ... DN 65, PN 6 ... PN 100
Process temperature−40…+250 °C
Max process pressure40 bar
Measurement technologymagnetostrictive
Electrical characteristics
Output signal4 ... 20 mA · HART® ver. 6
Power supplyDC 8 ... 30 V
Electrical connectionConnection terminals max. 1.5 mm²
Materials
Wetted parts materialStainless steel 1.4571 (316Ti), Stainless steel 1.4305 (303)
Operating environment
Ambient temperature−40…+85 °C
IP ratingIP68
Certifications and approvals
Certifications
RoHSEMC EN 61326ATEXIECExEMC directive EN 61326RoHS directiveCEEMCNAMUR NE43
Explosion protection
II 1D Ex ia IIIC T160 °C DaEx ia IIIC T160 °C DaEx i II 1G Ex ia IIC T6 ... T4 GaII 1/2G Ex ia IIC T6 ... T4 Ga/GbII 2G Ex ia IIC T6 ... T4 GbEx i Ex ia IIC T6 ... T4 GaEx ia IIC T6 ... T4 Ga/GbEx ia IIC T6 ... T4 GbII 1D Ex ia IIC T160℃DaEx ia IIC T160℃Da
Additional details
Datasheet languagesEN
Tables from datasheet
ModelDescription
FLM-CAStandard version
FLM-CAIExplosion-protected version
LogoDescriptionCountry
EU declaration of conformity ■ EMCdirective EN 61326 emission (group 1, class B) and immunity (industrial application) ■ RoHS directiveEuropean Union
■ ATEX directive (option - only with model FLM-CAI) Hazardous areas - Ex i II 1G Ex ia IIC T6 ...T4 Ga II 1/2G Ex ia IIC T6 ...T4 Ga/Gb II 2G Ex ia IIC T6 ...T4 Gb II 1D Ex ia IIIC T160 °C Da
IECEx (option) Hazardous areas - Ex i Ex ia IIC T6 ...T4 Ga Ex ia IIC T6 ...T4 Ga/Gb Ex ia IIC T6 ...T4 Gb Ex ia IIIC T160 °C DaInternational
Magnetostrictive level transmitter, models FLM-CA, FLM-CAI
Guide tube■ Ø6mm(max.1,000 mm) ■ Ø12 mm(max.3,000 mm)
Process connectionMounting thread downwards ■ G1/2" ...G2" ■ NPT 1/2" ...NPT 2"
Mounting flange ■ ANSI 1/2" ... 2 1/2", class 150 ... 600 ■ EN DN 20 ...DN 65, PN 6 ...PN 100 ■ DIN DN 20 ...DN 65, PN 6 ...PN 100
Other process connections on request
Magnetostrictive level transmitter, models FLM-CA, FLM-CAI
Materials
Wetted partsStainless steel 1.4571 (316Ti)
Connection headStainless steel 1.4305 (303)
Insertion length
Guide tubeØ6mm100 ...1,000mm
Guide tubeØ12mm100 …3,000mm
Measurement accuracy±1.25mm
Resolution0.1mm
Electrical connectionConnection terminals max. 1.5 mm²
Supply voltageDC 8 ...30V
Output signal■ 4 ... 20 mA(NAMUR NE43) ■ HART ® ver. 6
Vibration resistant version (option)to 4 g (only for guide tube Ø12 mm)
Operating pressureDepending on the float, max. 40 bar
Operating temperature
Guide tubeØ6mm-40 ...+125 °C
Guide tubeØ12mm-40 ...+250 °C
Ambient temperature-40 ...+85 °C
Ingress protection per EN 60529IP68
Configuration
Version without HART ® protocolVia two built-in buttons in the connection housings
Version with HART ® protocolVia two built-in buttons, HART ® communicator or HART ® interface in the connection housings
View all (5)
MaterialVersionDescriptionSuits guide tube Ø inmmMinimum dimension U inmmMax. operating pressure in barLimit density 85 %in kg/m 3
Stainless steel 1.4571 (316Ti)V18/42ACylinderØ18mm6486800
V27ACylinderØ27mm62216700
V29ASphereØ29mm62025920
V29A/40CylinderØ29mm122610620
V44ACylinderØ44mm123216720
V52ASphereØ52mm123240690
Titanium 3.7035 (Grade 2)T29ASphereØ29mm62130700
Buna (NBR)B18ACylinderØ18mm6383620
B20ACylinderØ20mm6263940
B23ACylinderØ23mm6316800
B25ACylinderØ25mm6203790
B30ACylinderØ30mm6513680
B40ACylinderØ40mm12363580