AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
FLC-2660 1
FLC-2660
On order
WIKA · Flow measurement · Family FLC

Flow meter

Insertion flow meter for small pipes (80...500 mm) with no moving parts, suitable for water distribution and leakage detection.
Protection
IP68
CEEMC directive EN 61326Low voltage directiveATEXIECEx
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The model FLC-2660 flow meter is an efficient solution when low costs and good performance are needed. It is suitable for small pipes between 80 mm and 500 mm with a maximum pressure of 10 bar.

The measuring instrument is installed using a welded brass bushing on the flow tube. The model FLC-2660 is available in different lengths in order that it can be matched to different pipe diameters, thus offering a wide range of applications.

A WIKA signal converter, either attached directly to the instrument or separated from it (e.g. model FLC-608), detects the potential difference between the electrodes, processes the signal to calculate the flow and manages communication with the external control systems.

Flow meter, model FLC-2660

Special features

  • Suitable for small pipes (80 ... 500 mm)
  • No moving parts
Identification
ModelFLC-2660
Product familyFLC
SubcategoryInsertion version
Measuring range
Pipe diameter80 mm
Accuracy
Accuracy3 %
Process conditions
Process connection
1 1/4" BSP1 1/4" NPT1 1/4" BSP female1 1/4" NPT female
Process temperature−40…+180 °C
Max process pressure10 bar
Measurement technologymagnetic
Materials
Wetted parts materialSS304, SS316L
Operating environment
Ambient temperature−40…+180 °C
IP ratingIP68
Weight2 kg
Certifications and approvals
Certifications
CEEMC directive EN 61326Low voltage directiveATEXIECEx
Explosion protection
IECEx (option for separated version)ATEX (option for separated version)ATEX directive (option for separated version)
Additional details
Datasheet languagesEN, DE
Tables from datasheet
Specifications
Pipe diameter80 ...500mm
Overall length317mm
Operating pressure≤ 10 bar
Medium temperature-40 ...+180 °C [-40 ...+ 356 °F] (in separated version)
Materials
Sensor housingSS304
Junction boxPolyoxymethylene
ElectrodesSS316L
Ingress protection per EN 60529IP68 (continuous immersion to 1.5 m) in separated version
Compatible signal converters■ Model FLC-608 ■ Model FLC-406
Electrical connectionCable gland M20 x 1.5, terminal block and sealing resin
Weight 1)Approx. 2 kg
LogoDescriptionCountry
EU declaration of conformityEuropean Union
EMCdirective EN 61326 emission (group 1, class B) and immunity (industrial application)
ATEX directive (option for separated version)
IECEx (option for separated version)International