Single point load cell, model F4818
The single point load cells feature high accuracy and a quick reponse. Moreover, they are insensitive to lateral and corner loads.
The load cells are easy to handle due to their simple force introduction. This is made perpendicular to the geometry.
Special features
- Measuring ranges 0 ... 20 kg to 0 ... 500 kg [0 ... 44 lbs to 0 ... 1,102 lbs]
- Load cell made from aluminium
- High accuracy and quick reponse
- Insensitive to lateral and corner load
- Simple design, easy installation
| Model | F4818 |
| Subcategory | Single point |
| Force ranges | 0…20 kg · 0…30 kg · 0…50 kg · 0…60 kg · 0…100 kg · 0…150 kg · 0…200 kg · 0…250 kg · 0…300 kg · 0…350 kg · 0…500 kg · 0…44 lbf · 0…66 lbf · 0…110 lbf · 0…132 lbf · 0…221 lbf · 0…331 lbf · 0…441 lbf · 0…551 lbf · 0…661 lbf · 0…772 lbf · 0…1102 lbf |
| Accuracy class | ±0.02 % Fnom |
| Process temperature | −10…+40 °C |
| Mounting type | Single-point |
| Output signal | 2.0 ±0.2 mV/V |
| Cell material | Aluminium |
| Ambient temperature | −20…+60 °C |
| IP rating | IP65 |
| Weight | 0.6 kg |
| Certifications | RoHSCE |
| Overload protection | 120 % |
| Cable length | 1.5 m |
| Datasheet languages | EN, DE |
| Model F4818 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Rated load F nom kg | 20 | 30 | 50 | 60 | 100 | 150 200 | 250 | 300 | 350 | 500 |
| Rated load F nom lbs | 44 | 66 | 110 | 132 | 221 | 331 441 | 551 | 661 | 772 | 1,102 |
| Relative linearity error d lin 1) | ±0.02%F nom | |||||||||
| Relative creep, 30 min. | ±0.02%F nom | |||||||||
| Relative reversibility error v | ±0.02%F nom | |||||||||
| Relative deviation of zero signal d S, 0 | ±2%F nom | |||||||||
| Temperature effect on zero signalTK 0 | ≤ ±0.025 %/10 K | |||||||||
| Temperature effect on characteristic value TK C | ≤ ±0.025 %/10 K | |||||||||
| Force limit F L | 120%F nom | |||||||||
| Breaking force F B | 200%F nom | |||||||||
| Material of the measuring body | Aluminium | |||||||||
| Rated temperature range B T;nom | -10 …+40 °C [+14 ...+104 °F] | |||||||||
| Operating temperature range B T, G | -20 …+60 °C [-4 ...+140 °F] | |||||||||
| Input resistance R e | 410 ±10Ω | |||||||||
| Output resistance R a | 350 ±5Ω | |||||||||
| Insulation resistance R is | ≥ 2,000 MΩ/DC 100V | |||||||||
| Output signal (rated characteristic value) C nom | 2.0 ±0.2 mV/V | |||||||||
| Electrical connection | Measuring cable ∅5x1,500 mm[∅0.19 x 59.06 in] | |||||||||
| Supply voltage U B, nom | DC 10V (max. 15 V) | |||||||||
| Ingress protection (per IEC/EN 60529) | IP65 | |||||||||
| Platform size | 450 x 450 mm[17.72 x 17.72 in] | |||||||||
| Weight | 0.6 kg [1.3 lbs] |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity RoHS directive | European Union |
| Supply voltage+ | Exc+ | Red |
|---|---|---|
| Supply voltage- | Exc- | Black |
| Signal+ | Sig+ | Green |
| Signal- | Sig- | White |
| Shield | Shield | Yellow-green |