Shear beam
Description
The model F3831 shear beam is suitable for static and dynamic measuring requirements in both tension and compression force direction. It serves for determining shear forces or weights in diverse application areas.
This shear beam is used in industrial weighing and laboratory technology, and also in the process industry, and features high measurement accuracy. By mounting on one or more model F3831 shear beams, platforms, tanks and vessels can be weighed very precisely.
Various load feet and mounting kits are available for mounting or attachment to the base.
Depending on the application, corresponding approvals are available.
For further approvals, see page 3
Shear beam, model F3831
The material of the measuring body is optionally steel or stainless steel. An mV/V signal is available as a standard output signal, which can be amplified to an analogue signal using a cable amplifier or summed via a junction box. A junction box with up to four inputs is available for combining several shear beams.
The measured weight can be displayed using a weighing indicator.
In combination with the model NETRIS ® F radio unit, the measured values of the instrument can be transmitted wirelessly. This radio unit can be used to realise solutions for web-based remote monitoring.
Special features
- Rated load 500 ... 10,000 kg [1,102 ... 22,046 lb]
- Material of the measuring body is steel or stainless steel
- High long-term stability
- High side load tolerance
| Model | F3831 |
| Subcategory | Shear beam |
| Force ranges | 250…10000 kg · 551…22046 lb |
| Accuracy class | ± 0.03 % Fnom |
| Process temperature | −10…+40 °C |
| Mounting type | Shear-beam |
| Output signal | 2.0 ±0.02 mV/V |
| Cell material | Steel, Stainless steel |
| Ambient temperature | −20…+80 °C |
| IP rating | IP67/IP68 |
| Weight | 4.5 kg |
| Certifications | EACRoHSEU |
| Explosion protection | Ex ia IIC T4 Ga |
| Overload protection | 150 % |
| Cable length | 6 m |
| Datasheet languages | EN |
| Standard | In accordance with directive VDI/VDE/DKD 2638 |
|---|---|
| Material of the measuring body | ■ Steel ■ Stainless steel |
| Type of measuring element | Strain gauge |
|---|---|
| Working range | Determination of shear forces or weights in tension or compression force direction |
| Input resistance R e | 385 ±10Ω |
| Output resistance R a | 350 ±5Ω |
| Relative linearity error d lin | ± 0.03%F nom |
|---|---|
| Relative repeatability error in unchanged mounting position b rg | ± 0.03%F nom |
| Relative reversibility error v | ± 0.03%F nom |
| Relative creep, 30 min at F nom | ± 0.03%F nom |
| Relative deviation of zero signal d S,0 | ±2%F nom |
| Temperature effect on zero signal TC 0 | ≤ ±0.025 %/ 10 K |
| Temperature effect on characteristic value TC C | ≤ ±0.025 %/ 10 K |
| kg | lb |
|---|---|
| 250 | 551 |
| 500 | 1,102 |
| 750 | 1,653 |
| 1,000 | 2,204 |
| 1,500 | 3,306 |
| 2,000 | 4,409 |
| 2,500 | 5,511 |
| 3,000 | 6,613 |
| 5,000 | 11,023 |
| 7,500 | 16,534 |
| 10,000 | 22,046 |
View all (14)
| Force limit F L | 150%F nom |
|---|---|
| Breaking force F B | 200%F nom |
| Rated characteristic value C nom | 2.0 ±0.02 mV/V |
|---|---|
| Supply voltage U B | DC 5 ...10V (max. 15 V) |
| Connection type | Cable | |
|---|---|---|
| Cable diameter | ≤ 5 t [11,023 lb] | 5 mm[0.197 in] |
| > 5 t [11,023 lb] | 6 mm[0.236 in] | |
| Cable length | 6,000 mm[236 | in] |
| Insulation resistance R is | ≥ 5,000 MΩ/ DC | 100V |
| Material | PVC |
| Signal | Cable colour | |
|---|---|---|
| Exc+ | Supply voltage + | Red |
| Exc- | Supply voltage - | Black |
| Sig+ | Signal + | Green |
| Sig- | Signal - | White |
| Shield | Shield | Green-yellow |
| Rated temperature range B T, nom | -10 …+40 °C [14 ...+104 °F] |
|---|---|
| Operating temperature range B T, G | -20 …+80 °C [-4 ...+176 °F] |
| Ingress protection per IEC/EN 60529 | IP67/IP68 |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity | European Union | |
| EAC RoHS directive | Eurasian Economic Community |
| Logo | Description | Region | ||
|---|---|---|---|---|
| NEPSI | China | |||
| - Ex | Zone 0 gas | Ex ia IIC T4 Ga |
| Rated load in kg | Dimensions inmm | Weight in kg | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | B | C | D | E | F | ∅G | H | ∅K | M | ||
| 250 ... 2,500 | 12.7 | 76.2 | 25.4 | 130 | 31.8 | 31.8 | 13 | 15.7 | 13.5 | M12x1.75 | 1 |
| 3,000, 5,000 | 19 | 95.3 | 38.1 | 171.5 | 38.1 | 38.1 | 20 | 26 | 20 | M18 x 1.5 | 1.9 |
| 7,500, 10,000 | 25.3 | 124 | 50.8 | 225.5 | 50.8 | 50.8 | 27 | 25.4 | 27 | M24 x 2 | 4.5 |
| Rated load in lb | Dimensions in inch | Weight in | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| A | B | C | D | E | F | ∅G | H | ∅K | M | lb | |
| 551 ... 5,511 | 0.5 | 3 | 1 | 5.11 | 1.25 | 1.25 | 0.51 | 0.61 | 0.53 | M12x1.75 | 2.4 |
| 6,613, 11,023 | 0.74 | 3.75 | 1.5 | 6.75 | 1.5 | 31.5 | 0.78 | 1.02 | 0.78 | M18 x 1.5 | 4.18 |
| 16,534, 22,046 | 0.99 | 4.88 | 2 | 8.87 | 2 | 2 | 1.06 | 1 | 1.06 | M24 x 2 | 9.92 |
| Model | Description | Order number |
|---|---|---|
| Mounting kit for shear or bending beams → See data sheet AC 50.17 | On request | |
| Analogue cable amplifier → See data sheet FO 58.04 | 64440308 | |
| Junction box for load cells → See data sheet FO 58.02 | 64418893 | |
| Weighing indicator → See data sheet AC 50.14 | 14671552 | |
| Radio unit with BLE and LoRaWAN ® for force measuring instruments → See data sheet AC 40.10 | On request | |
| Connectors with moulded cable Straight or angled version, 4- or 5-pin → See data sheet AC 50.08 | On request |
Couldn't find the answer in the documentation? An engineer will reply within a business day.