AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
F2301_F23C1_F23S1 1
F2301_F23C1_F23S1
In stock at WIKA
WIKA · Force measurement · Family F2301_F23C1_F23S1

Tension/compression force transducer

With thin-film technology up to 500 kN
Price
From €675
Confirm at order time
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The tension/compression force transducers are suitable for static and dynamic measuring requirements in the direct force flow. They serve for determining tension and/or compression forces in diverse application areas.

These force transducers are very often used in linear drives as well as in the areas of special machine construction and laboratory technology. The force transducers are also perfectly suited for hoists and crane systems.

The corresponding technical and regional approvals of these force transducers are, of course, available as options.

For further approvals see page 4

Tension/compression force transducer, model F2301

The force transducers are made of high-strength, corrosion resistant stainless steel 1.4542, whose properties are particularly suitable for the transducer's application area.

As output signals, the common active current and voltage outputs are available (4 … 20 mA, 0 … 10 V). Also redundant output signals and CANopen ® protocols are possible.

The tension/compression force transducers can be integrated into a certified WIKA overload protection with model ELMS1 (DIN EN ISO 13849-1 with PL d/Cat. 3).

Special features

  • Measuring ranges 0 ... 1 kN to 0 ... 500 kN [0 ... 224.8 lbf to 0 ... 112,404 lbf]
  • Corrosion-resistant stainless steel design
  • Integrated amplifier
  • High long-term stability, high shock and vibration resistance
  • Good reproducibility, easy installation
Specifications are being prepared — full datasheet available on request.
Tables from datasheet
ModelF2301 and F23C1 UL approvalF23S1
Rated force F nom kN1, 2, 3, 5, 10, 20, 30, 50, 100, 200, 300, 5003, 5, 10, 20, 30, 50, 100
Rated force F nom lbf225; 450; 674; 1,124; 2,248; 4,496; 6,744; 11,240; 22,481; 44,962; 67,443; 112,404674; 1,124; 2,248; 4,496; 6,744; 11,240; 22,481
Relative linearity error d lin 1)±0.5%F nom
Relative reversibility error v< 0.1%F nom
Temperature effect on
the characteristic valueTK c0.2%F nom / 10 K0.4%F nom / 10 K
the zero signalTK 00.2%F nom / 10 K0.4%F nom / 10 K
Force limit F L150%F nom
Breaking force F B300%F nom
Permissible vibration loading F rb50%F nom (in accordance with DIN 50100)
Rated displacement (typical) s nom
< 10 kN [< 2,248 lbf]< 0.02 mm[< 0.00079 in]
< 100 kN [< 22,481 lbf]< 0.2 mm[< 0.0079 in]
Rated temperature range B T;nom-20 …+80 °C [-4 ...+176 °F]
Operating temperature range B T, G■ -30 …+80 °C [-22 ...+176 °F] ■ -40 …+80 °C [-40 ...+176 °F]-30 …+80 °C [-22 ...+176 °F]
Storage temperature range B T, S-40 …+85 °C [-40 ...+185 °F]
Electrical connection■ Circular connector M12 x 1, 5-pin ■ CANopen ® , circular connector M12 x 1, 5-pin2-connector variant, 4-pin
Characteristic value range B C (Output signal)■ 4 …20mA, 2-wire ■ 4 …20mA, 3-wire ■ DC 0 …10V, 3-wire ■ Optional redundant signal ■ CANopen ® Protocol in accordance with CiA ® 301, instrument profile CiA ® 404, communication servicesRedundant, opposing 4 …20mA, 3-wire / 20 …4mA,3-wire Version in accordance with requirements for functional safety per machinery directive 2006/42/EC asWIKA overload protection with model ELMS1 (DIN EN ISO 13849-1 with PL d/cat. 3).
Insulation resistance> 2GΩ
Current/power consumption■ Current output 4 …20mA, 2-wire: Signal current ■ Current output 4 …20mA, 3-wire:<8mA ■ Voltage output:<8mA ■ CANopen ® :<1WCurrent output 4 …20mA:Signal current
Supply voltage UB■ DC 9 ...36V for current output ■ DC 13 ...36V for voltage output ■ DC 9 ...36V for CANopen ®DC 10 …30Vfor current output
Load■ ≤ (UB - 10 V) / 0.024 A for current output ■ > 25 kΩ for voltage output■ ≤ (UB - 10 V) / 0.020 A (channel 1) for current output ■ ≤ (UB - 7 V) / 0.020 A (channel 2) for current output
Ingress protection (per IEC/EN 60529)
Unplugged stateIP66, IP67IP67
Plugged-in stateIP68, IP69, IP69K
Electrical protectionReverse polarity protection, overvoltage and short-circuitresistance
Vibration resistance20 g, 100 h, 50 ... 150 Hz (per DIN EN 60068-2-6)
Shock resistanceDIN EN 60068-2-27
Immunity■ In accordance with DIN EN 61326-1/DIN EN 61326-2-3 ■ EMC-strengthened versions
Intended useIndoor and outdoor use, typically at altitudes of up to 2,500m[8,202.5 ft] above sea level.
ModelF23C1 ATEX/IECEx EX ib 1)F2301 Signal jump
Rated force F nom kN1, 2, 3, 5, 10, 20, 30, 50, 100
Rated force F nom lbf225; 450; 674; 1,124; 2,248; 4,496; 6,744; 11,240; 22,481
Relative linearity error d lin 2)±0.5%F nom
Relative reversibility error v< 0.1%F nom
Temperature effect on
the characteristic valueTK c0.4%F nom / 10 K0.2%F nom / 10 K
the zero signalTK 00.4%F nom / 10 K0.2%F nom / 10 K
Force limit F L150%F nom
Breaking force F B300%F nom
Permissible vibration loading F rb50%F nom (in accordance with DIN 50100)
Rated displacement (typical) s nom
< 10 kN [< 2,248 lbf]< 0.02 mm[< 0.00079 in]
< 100 kN [< 22,481 lbf]< 0.2 mm[< 0.0079 in]
Rated temperature range B T;nom-20 …+80 °C [-4 ...+176 °F]
Operating temperature range B T, GEx II 2G Ex ib IIC T4 Gb -25 °C <T amb < +85 °C Ex II 2G Ex ib IIC T3 Gb -25 °C <T amb < +100 °C Ex I M2 Ex ib I Mb -25 °C <T amb < +85 °C Ex II 2G Ex ib IIC T4 Gb -40 °C <T amb < +85 °C Ex I M2 Ex ib I Mb-30 …+80 °C [-22 ...+176 °F]
Storage temperature range B T, S-40 …+85 °C [-40 ...+185 °F]
Electrical connectionCircular connector M12 x 1, 4-pin
Characteristic value range B C (Output signal)4 …20mA, 2-wire■ 4 …16mA, 3-wire 3) ■ DC 2 …8V, 3-wire 3)
Insulation resistance> 2GΩ
Current/power consumptionCurrent output4…20mA 2-wire: Signal current■ Current output4…20mA 2-wire: Signal current ■ Current output4…20mA 3-wire:<8mA ■ Voltage output:<8mA
Supply voltage UBDC 10 ...30V for current output■ DC 9 …36Vfor current output ■ DC 13 ...36V for voltage output
Load■ ≤ (UB - 10 V) / 0.024 A for current output ■ > 25 kΩ for voltage output
Ingress protection (per IEC/EN 60529)
Unplugged stateIP66, IP67IP67
Plugged-in stateIP68, IP69, IP69K
Electrical protectionReverse polarity protection, overvoltage and short-circuit resistance
Vibration resistance20 g, 100 h, 50 ... 150 Hz (per DIN EN 60068-2-6)
Immunity■ In accordance with DIN EN 61326-1/DIN EN 61326-2-3
Rated force in kNDimensions inmmTightening torque (Nm)
ABDEFGHK1K2LMØN -0.1Sphere RRated dis- placement
1, 2, 325.32424234.31.56567670M129.560< 0.0215
525.32424234.31.56567670M129.560< 0.0215
1025.32431234.31.56567677M129.580< 0.0215
2025.32635343.82105676103M20 x 1.517100< 0.260
30262744343.821056.576.5112M20 x 1.517120< 0.260
Rated force in lbfDimensions in inchTightening torque (Nm) dis-
ABDEFGHK1K2LMØN -0.004Sphere RRated placement
225, 450, 6740.990.990.990.90.170.060.242.22.992.75M120.372.36< 0.0007915
1,1240.990.990.990.90.170.060.242.22.992.75M120.372.36< 0.0007915
2,2480.990.990.990.90.170.060.242.22.993.03M120.373.15< 0.0007915
4,4960.9911.371.340.150.080.392.22.994.05M20 x 1.50.673.94< 0.007960
6,7441.021.061.731.340.150.080.392.223.014.41M20 x 1.50.674.72< 0.007960
View all (20)
Rated force in kNDimensions inmmTightening torque MA (Nm)
ØCDEFGHK1K2LMØN -0.1Sphere RRated dis- placement
5038504052125868130M24 x 220150< 0.2110
1004654717.5319.562.582.5196M39 x 334200< 0.2390
2006767827.5322.57393231M45 x 340250< 0.2495
3007373981432865.585.5269M56 x 450300< 0.2640
50094941131733265.585.5320M64 x 458400< 0.2760
Rated force in lbfDimensions in inchTightening torque MA (Nm)
ØCDEFGHK1K2LMØN -0.004Sphere RRated dis- placement
11,2401.51.971.570.20.080.472.282.685.12M24 x 20.795.9< 0.0079110
22,4811.812.162.80.30.120.762.463.257.72M39 x 31.347.87< 0.0079390
44,9622.642.643.230.30.120.882.873.669.09M45 x 31.579.84< 0.0079495
67,4432.872.873.860.550.121.12,583,3710.6M56 x 41.9711.8< 0.0079640
112,4043.73.74.450.670.121.262,583,3712.6M64 x 42.2815.75< 0.0079760
Rated force in kNDimensions inmmTightening torque (Nm)
ABDEFGHK1K2LMØN -0.1Sphere RRated dis- placement
1, 2, 3, 525.32424234.31.5668.888.870M129.560< 0.0215
1025.32431234.31.5668.888.877M129.580< 0.0215
2025.32635343.821068.888.8103M20 x 1.517100< 0.260
30262744343.821069.189.1112M20 x 1.517120< 0.260
Rated force in lbfDimensions in inchTightening torque MA (Nm)
ABDEFGHK1K2LMØN -0.004Sphere RRated dis- placement
225, 450 674, 1,1240.990.940.940.910.170.060.242.713.52.75M120.372.36< 0.0007915
2,2480.990.941.220.910.170.060.242.713.53.03M120.373.15< 0.0007915
4,4960.991.021.381.340.150.080.392.713.54.06M20 x 1.50.673.94< 0.007960
6,7441.021.061.731.340.150.080.392.723.514.41M20 x 1.50.674.72< 0.007960
Rated force in kNDimensions inmmTightening torque MA (Nm)
ØADEFGHK1K2LMØN -0.1Sphere RRated dis- placement
50385040521273.393.3130M24 x 220150< 0.2110
1004654717.5319.577.397.3196M39 x 334200< 0.2390
2006767827.5322.587.8107.8231M45 x 340250< 0.2495
3007373981432892.3112.3269M56 x 450300< 0.2640
500949411317332102.8122.8320M64 x 458400< 0.2760
Rated force in lbfDimensions in inchTightening torque (Nm) dis-
ØADEFGHK1K2LMØN -0.004Sphere RRated placement
11,2401.51.971.570.20.080.472.893.675.12M24 x 20.795.9< 0.0079110
22,4811.812.162.80.300.120.763.043.837.72M39 x 31.347.87< 0.0079390
44,9622.642.643.230.300.120.883.464.249.09M45 x 31.579.84< 0.0079495
67,4432.872.873.860.550.121.13.634.4210.6M56 x 41.9711.8< 0.0079640
112,4043.73.74.450.670.121.264.054.8312.6M64 x 42.2815.75< 0.0079760
Rated force in kNDimensions inmmTightening torque (Nm)
ABDEFGHK1K2LMN -0.1Sphere R
525.32424234.31.56769670M129.56015
1025.32431234.31.56769677M129.58015
2025.32635343.82107696103M20 x 1.51710060
30262744343.82107696112M20 x 1.51712060
Rated force in lbfDimensions in inchTightening torque MA (Nm)
ABDEFGHK1K2LMØN -0.004Sphere R
1,1241.00.940.940.90.170.060.242.993.872.75M120.372.3615
2,2481.00.941.220.90.170.060.242.833.873.03M120.373.1515
4,4961.01.021.381.340.150.080.392.833.874.06M20 x 1.50.673.9460
6,7441.021.061.731.340.150.080.392.833.874.41M20 x 1.50.674.7260
Rated force in kNDimensions inmmTightening torque MA (Nm)
ØABDEFGHK1K2LMN -0,1Sphere RRated dis- placement
5038--5040521280100130M24 x 320150< 0.2110
10046--54717.5319.585105196M39 x 334200< 0.2390
20067--67827.5322.595115231M45 x 340250< 0.2495
30073--739814328100120269M56 x 450300< 0.2640
50094--9411317332110130320M64 x 458400< 0.2760
Rated force in lbfDimensions in inchTightening torque MA (Nm)
ØABDEFGHK1K2LMØN -0,004Sphere RRated dis- placement
11.2401.5--1.971.570.20.080.473.153.945.12M24 x 30.795.91< 0.0079110
22.4811.81--2.132.80.30.120.773.354.137.72M39 x 31.347.87< 0.0079390
44.9622.64--2.643.230.30.120.893.744.539.09M45 x 31.579.84< 0.0079495
67.4432.87--2.873.860.550.121.103.944.7210.59M56 x 41.9711.81< 0.0079640
112.4053.7--3.74.450.670.121.264.335.1212.60M64 x 42.2815.75< 0.0079760
Rated force in kNDimensions inmm
BCEFGHIJLMØ N -0.1Sphere R
3-72225.32312.71.5618.7152.575M129.560
6-1325.325.32613.51.5821.5152.585M16 x 1.51380
12-2627.527.63420.221030.2152.5108M20 x 1.517120
18-403327.6402321235152.5126M24 x 220120
31-704040482521540157.4154M30 x 226150
67-15160607847.8319.767.5177.4223M39 x 338250
Rated force in lbfDimensions in inch
BCEFGHIJLMØN -0.004Sphere R
674.48-1,5740.870.990.90.50.060.270.73662.95M120.372.36
1,349-2,9230.990.9910.530.060.3150.8563.35M16 x 1.50.513.15
2,698-5,8451.081.091.340.790.0790.391.1964.25M20 x 1.50.674.72
4,047-8,9921.31.091.570.90.0790.471.3864.96M24 x 20.794.72
6,969-15,7371.571.571.890.980.0790.591.576.26.06M30 x 21.025.9
15,062-33,9462.362.363.071.880.190.782.666.988.78M39 x 31.59.84
SignalDescription
UBVoltage source for sensor
UB+Sensor- supply voltage (+)
UB-Sensor- supply voltage (-)
S+Output signal (+)
S-Output signal (-)
0 V0V potential
SignalDescription
AAmmeter
VVoltmeter
+ -Voltage source
Switch
Shield (grounding)
Signal4 ... 20 mA, 2-wireCable colour
UB+/S+1Brown
0 V/S-3Black
ShieldCase / connector-
Signal4 ... 20 mA, 3-wireCable colour
UB+1Brown
S+4Black
0 V/S-3Blue