WIKA · Force measurement · Family F1848
Compression force transducer
Compression force transducer standard version from 1 t with redundant output signal for safety applications, IP67 protection.
Range
1…1 t
Output
4 ... 20 mA, 3-wire, 2 x 4 ..…
Accuracy
±0.15 % Fnom
Protection
IP67
Price
On request
Depends on configuration
Description
The force transducer model F1848 is used because of its redundant output signal very often for monitoring used by safety applications. The spherical calotte (spherical load application button) allows for a very simple force introduction.
Compression force transducers are used for the determination of compression forces in a wide variety of applications and are suitable for static and dynamic measuring requirements.
Compression force transducer standard, model F1848
Special features
- Measuring range from 1 t
- Relative linearity error ±0.15 % F nom
- Redundant output signal for safety applications
- Low installation height, easy to install
- Ingress protection: IP67
Identification
| Model | F1848 |
| Subcategory | Compression force transducer |
Measuring range
| Force ranges | 1…1 t · 2205…2205 lbf |
Accuracy
| Accuracy class | ±0.15 % Fnom |
Process conditions
| Process temperature | −10…+40 °C |
| Mounting type | Compression |
Electrical characteristics
| Output signal | 4 ... 20 mA, 3-wire, 2 x 4 ... 20 mA (redundant), 4 ... 20 mA / 20 ... 4 mA (opposite directions) |
Materials
| Cell material | Stainless steel |
Operating environment
| Ambient temperature | −20…+80 °C |
| IP rating | IP67 |
| Weight | 1 kg |
Additional details
| Overload protection | 150 % |
| Datasheet languages | EN |
Tables from datasheet
| Model F1848 | |
|---|---|
| Rated load F nom t / [lbs] | from 1 / [2,205 lbs] |
| Relative linearity error d lin | ±0.15 %Fnom |
| Relative creep, 30 min. at F nom | ±0.1 %Fnom |
| Relative reversibility error v | ±0.1 %Fnom |
| Relative span in unchanged mounting situation b rg | ±0.05 %Fnom |
| Temperature effect on the zero signalTK 0 | ±0.1 %Fnom/10 K |
| Temperature effect on the characteristic value TK C | ±0.1%F nom /10 K |
| Limit force F L | |
| for 1 t / [2,205 lbs] | 200%F nom |
| from 2 t / [4,409 lbs] | 150%F nom |
| Breaking force F B | |
| for 1 t / [2,205 lbs] | 250%F nom |
| from 2 t / [4,409 lbs] | 200%F nom |
| Material of the measuring body | Stainless steel |
| Rated temperature range B T, nom | -10 …+40 °C [-50 …+104 F] |
| Service temperature range B T, G | -20 …+80 °C [-68 …+176 F] |
| Output signal (rated characteristic value) C nom | 4 ... 20 mA, 3-wire |
| 2 x 4 ... 20 mA, redundant | |
| Redundant, in opposite directions 4 ... 20 mA/ 20 ...4mA | |
| Electrical connection | |
| Standard | Cable output, free wire |
| Round connector M12 x 1, 4- or 5-pin | |
| Option | Customer specifical connector |
| Voltage supply | DC 10 ...30V |
| Burden | ≤ (auxiliary power - 10 V) / 0.024 A for current output |
| Ingress protection (per IEC/EN 60529) | IP67 |
| Weight | 1 kg [2.2 lbs] |
Electrical connection
| Conductor | Cable Colour |
|---|---|
| UB (+) | Red |
| UB (-) | Black |
| S (+) | Green |
| Shield | Yellow-green |
Electrical connection, M12 x 1, 4-pin
| 4 ... 20 mA / 20 ... 4 mA (redundant) | ||
|---|---|---|
| Conductor | Connector 1 | Connector 2 |
| UB (+) | 1 | 1 |
| UB (-) | 3 | 3 |
| S (+): Kanal 1 | 4 | - |
| S (+): Kanal 2 | - | 4 |
| Shield | Case | Case |