WIKA · Force measurement · Family F1811
Compression force transducer
Compression force transducer, Standard version to 300 kN, stainless steel, IP66, for industrial applications such as production lines, presses, and platform scales.
Range
0…300 kN
Output
1.5 ±0.15 mV/V
Accuracy
0.1 % Fnom
Protection
IP66
CERoHSEAC
Price
On request
Depends on configuration
Description
Due to its compact design, the model F1811 force transducer is used very often in industrial applications such as production lines and control units. The spherical calotte (spherical load application button) allows for a very simple force introduction.
Compression force transducers are used for the determination of compression forces in a wide variety of applications and are suitable for static and dynamic measuring requirements.
Compression force transducer, model F1811
Special features
- Measuring ranges 0 ... 2.5 kN to 0... 300 kN
- Relative linearity error 0.1 % F nom
- Stainless steel version, completely welded
- Low installation height, easy to install
- Ingress protection IP67
Identification
| Model | F1811 |
| Subcategory | Compression force transducer |
Measuring range
| Force ranges | 0…2.5 kN · 0…5 kN · 0…10 kN · 0…20 kN · 0…30 kN · 0…50 kN · 0…100 kN · 0…200 kN · 0…300 kN · 0…552 lbf · 0…1124 lbf · 0…2250 lbf · 0…4500 lbf · 0…6744 lbf · 0…11240 lbf · 0…22500 lbf · 0…45000 lbf · 0…67443 lbf |
Accuracy
| Accuracy class | 0.1 % Fnom |
Process conditions
| Process temperature | −10…+60 °C |
| Mounting type | Compression |
Electrical characteristics
| Output signal | 1.5 ±0.15 mV/V |
Materials
| Cell material | Stainless steel |
Operating environment
| Ambient temperature | −20…+80 °C |
| IP rating | IP66 |
| Weight | 3.2 kg |
Certifications and approvals
| Certifications | CERoHSEAC |
Additional details
| Overload protection | 150 % |
| Cable length | 5 m |
| Datasheet languages | EN |
Tables from datasheet
| Model F1811 | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Rated force F nom kN | 2.5 | 5 | 10 | 20 | 30 | 50 | 100 | 200 | 300 |
| Rated force F nom lbf | 552 | 1,124 | 2,250 | 4,500 | 6,744 | 11,240 | 22,500 | 45,000 | 67,443 |
| Relative linearity error d lin | 0.1%F nom | ||||||||
| Relative creep, 30 min. at F nom | 0.1%F nom | ||||||||
| Relative reversibility error v | 0.1%F nom | ||||||||
| Relative span in unchanged mounting situation b rg | 0.1%F nom | ||||||||
| Relative deviation of zero signal d S, 0 | ±2%F nom | ||||||||
| Temperature effect on the zero signalTK 0 | 0.05%F nom /10 K | ||||||||
| Temperature effect on the characteristic value TK C | 0.05%F nom /10 K | ||||||||
| Limit force F L | 150%F nom | ||||||||
| Breaking force F B | 200%F nom | ||||||||
| Material of the measuring body | Stainless steel | ||||||||
| Rated temperature range B T, nom | -10 …+60 °C [-50 …+140 °F] | ||||||||
| Service temperature range B T, G | -20 …+80 °C [-68 …+176 °F] | ||||||||
| Input resistance R e | 750 ±10Ω | ||||||||
| Output resistance R a | 700 ±5Ω | ||||||||
| Insulation resistance Ris | ≥ 5,000 MΩ/DC 100V | ||||||||
| Output signal (rated characteristic value) C nom | 1.5 ±0.15 mV/V | ||||||||
| Electrical connection | Cable Ø5×5,000 mm[Ø0.197 in × 197 in] | ||||||||
| Voltage supply | DC 10V (max. 15 V) | ||||||||
| Ingress protection (per IEC/EN 60529) | IP66 | ||||||||
| Weight | |||||||||
| 2.5 kN ... 100 kN | 1.2 kg [2.65 lbs] | ||||||||
| 200 kN | 1.6 kg [3.53 lbs] | ||||||||
| 300 kN | 3.2 kg [7.05 lbs] |
| Logo | Description | Country |
|---|---|---|
| EU Declaration of Conformity | European Union | |
| EMCDirective | ||
| RoHS Directive | ||
| EAC (Option) | Eurasian Economic Community | |
| EMV-Directive |
| Rated force in kN [lbf] | Dimensions in mm[in] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| ØA | B | C | ØD | SR E | F | G | ØK | H | L | M | |
| 2.5 [552] / 5 [1,124] / 10 [2,250] / 20 [4,500] / 30 [6,744] / 50 [11,240] / 100 [22,500] | 82 [3.23] | 44 [1.73] | 32 [1.26] | 22 [0.87] | 50 [1.97] | 14 [0.55] | 13 [0.51] | 68 [2.67] | M8 | 5,000 [197] | 15.7 [0.62] |
| 200 [45,000] | 100 [3.94] | 48 [1.89] | 36 [1.41] | 28 [1.10] | 100 [3.94] | 14 [0.55] | 13 [0.51] | 80 [3.15] | M8 | 5,000 [197] | 15.7 [0.62] |
| 300 [67,443] | 126 [4.96] | 54 [2.12] | 40 [1.57] | 35 [1.38] | 100 [3.94] | 14 [0.55] | 13 [0.51] | 101 [3.98] | M10 | 5,000 [197] | 15.7 [0.62] |
Electrical connection
| Excitation voltage (+) | Red |
|---|---|
| Excitation voltage (-) | Black |
| Signal (+) | Green |
| Signal (-) | White |
| Shield | Shield |
Industry
Machinery
Production lines · Presses
Couldn't find the answer in the documentation? An engineer will reply within a business day.