WIKA · Force measurement · Family F1270

High‑capacity load cell

With bilateral spherical force introduction up to 300 t [661,500 lb]
Range
0…300 t
Output
2.0 ±0.1 mV/V
Accuracy
0.04% F nom
Protection
IP69K
RoHSEAC RoHSCEEAC
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The model F1270 high-capacity load cell with strain gauges is designed for measuring very high loads and has been specially designed for use in container and silo weighing technology.

The spherical cap with convex surface is used to transfer compressive forces and ensures axial, perpendicular and centred force introduction. The force is thus transmitted centrally and evenly into the instrument. This enables precise measurement of the actual compression forces in a wide variety of applications.

The measuring body is elastically deformed by a compression force introduced in the force direction. The resulting mechanical tensions are measured by the strain gauges, converted into an electrical output signal and output as an mV/V signal.

Special features

  • Rated loads from 0 ... 7.5 t to 0 ... 300 t [0 ... 16,535 lb to 0 ... 661,500 lb]
  • Relative linearity error from 0.04 % F nom
  • Rocker column load cell
  • Robust design and long‑term stability
  • Encapsulation, hermetically sealed and welded
Identification
ModelF1270
SubcategoryRocker column load cell
Measuring range
Force ranges0…7.5 t · 0…15 t · 0…22.5 t · 0…30 t · 0…40 t · 0…50 t · 0…100 t · 0…150 t · 0…300 t · 0…16535 lb · 0…33069 lb · 0…49604 lb · 0…66138 lb · 0…88185 lb · 0…110231 lb · 0…220500 lb · 0…330750 lb · 0…661500 lb · 7.5…300 t · 16535…661500 lb
Accuracy
Accuracy class0.04% F nom
Process conditions
Mounting typeCompression
Electrical characteristics
Output signal2.0 ±0.1 mV/V
Materials
Cell materialStainless steel
Operating environment
Ambient temperature−40…+80 °C
IP ratingIP69K
Weight32.8 kg
Certifications and approvals
Certifications
RoHSEAC RoHSCEEAC
Additional details
Overload protection200 %
Cable length18 m
Datasheet languagesEN
Tables from datasheet
Basic informations / Version per standard
StandardIn accordance with VDI/VDE/DKD 2638
Material of the measuring bodyStainless steel
Ingress protection (per IEC/EN 60529)IP69K
Down to a water depth of 2 m[6.56 ft]IP68
Measuring element
Type of measuring elementStrain gauges
Range of useFor static force measurement
Input resistance R e1,150 ±50Ω
Output resistance R a1,000 ±2Ω
Force introductionCompression force applied axially and centrally to the spherical cap (one-sided).
Accuracy specifications
Relative linearity error d lin±0.04%F nom
Relative repeatability error in unchanged mounting position b rg±0.04%F nom
Relative creep, 30 min at F nom±0.04%F nom
Relative deviation of zero signal d S, 0±5%F nom
Temperature effect on zero signal TC 0≤ ±0.04 %/ 10 K
Temperature effect on characteristic value TC C≤ ±0.02 %/ 10 K
Rated load F nomWeight
kglbkglb
7.516,5351.32.87
1533,0691.43.09
22.549,6041.53.31
3066,1383.47.5
4088,1853.67.94
50110,2314.59.92
100220,50012.928.4
150330,75017.137.7
300661,50032.872.3
View all (15)
Further details on the measuring range
Force limit F L200%F nom
Breaking force F B> 300%F nom
Output signal
Rated characteristic value C nom2.0 ±0.1 mV/V
Voltage supplyDC 5 ...15V for mV/V ouput
Electrical connection
Connection typeCable outlet, shielded, flying leads
Cable diameter
Rated load F nom : 7.5 ... 22.5 t [16,535 ... 49,604 lb]Ø5mm[0.197 in]
Rated load F nom : 30 ... 300 t [66,138 ... 110,231 lb]Ø7.8 mm[0.307 in]
Cable length
Rated load F nom : 7.5 ... 22.5 t [16,535 ... 49,604 lb]12 m[39.37 ft]
Rated load F nom : 30 ... 300 t [66,138 ... 661,500 lb]18 m[59.1 ft]
MaterialPUR (polyurethane)
Insulation resistance R is>5GΩ
Cable outlet, shielded, flying leads
4-wire
Exc +Green (GN)
Exc -Black (BK)
Sig +White (WH)
Sig -Red (RD)
ShieldYellow (YE)
Operating conditions
Operating temperature range B T, G-40 …+80 °C [-40 ...+176 °F]
Humidity35 ... 85 %relative humidity
CondensationNon-condensing
EncapsulationCompletely hermetically sealed, cable connection by means of a glass feedthrough
Operating altitude≤ 2,500 m[8,202 ft] above sea level
Packaging and instrument labelling
PackagingIndividual packaging
IInstrument labelling (product label)→ See operating instructions 14723453
LogoDescriptionRegion
EU declaration of conformityEuropean Union
RoHS directive
EAC RoHS directiveEurasian Economic Community
Rated load F nom in tDimensions inmm
H1H2H3H4H5H6H7H8D1D2
7.58944172311628752869
158944172311628752869
22.58944172311628752869
30140702628136.539843981
401507531331311.739843981
50178893234178.544944499
1001788938.538.51712629462141.3
15021010542.742.720.612.876.2121.576.2165
30028014055.955.92521.5100121.5100165
Rated load F nom in lbDimensions in inch
H1H2H3H4H5H6H7H8D1D2
16,5353.51.730.670.910.430.241.112.951.112.72
33,0693.51.730.670.910.430.241.112.951.112.72
49,6043.51.730.670.910.430.241.112.951.112.72
66,1385.512.761.021.100.5120.2561.543.311.543.19
88,1855.912.951.221.300.5120.461.543.311.543.19
110,2317.013.501.261.340.670.3351.733.701.733.898
220,5007.013.501.441.520.670.4722.443.72.445.56
330,7508.274.131.681.680.8110.5043.04.783.06.5
661,50011.025.512.202.200.9840.8463.944.783.946.5
Rated load F nom in tRestoring force RF** kNDimensions inmm
S max *S nom ***
7.5114.50.5
15204.50.6
22.5304.50.6
303410.50.29
4037100.8
505191
10015211.50.3
15024014.50.35
300468150.5
Rated load F nom in lbRestoring force RF** lbDimensions in inch
S max *S nom ***
16,5352,4730.1770.02
33,0694,4960.1770.24
49,6046,7440.1770.24
66,1387,6440.4130.011
88,1858,3180.3940.031
110,23111,4650.3540.039
220,50034,1710.4530.012
330,75053,9540.5710.014
661,500105,2110.5910.02
LogoDescriptionOrder number
Mounting kit, model AZK01 (Indicative image)On request
Analogue cable amplifier, model B1940 Analogue cable amplifier for adapting the output signal of the strain gauge instruments to 4 ... 20 mA, 0 ... 20 mAor 0 ...10V for indicators or to the downstream controller83805811
Junction box, model B6578 For the parallel connection of up to 4 force transducers or load cells64418893
Weighing transmitter, model FE230 An amplifier for sensors with mV/V signal, DIN-rail mounting.On request
Weighing indicator, model FE430 For the connection of 4- or 6-wire load cells with mV/V outputOn request
Hand-held indicator, Typ FE630 A mobile indicator and data logger for instruments with mV/V output14785125